Explained testing results and areas to watch in the future. Added necessary amount of Freon. Provided whole house fan option to reduce costs and prolong current AC unit’s life.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Jet was great!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service’!

The crew did a good and was very courteous.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service. Efficient, thorough, friendly and professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

They keep getting it right

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for rancho murieta, ca

Andre B.

Andre B. Job Checkin

Performed heating and AC tuneup for both Lennox heat pump systems. Checked all safeties and connections. Changed both Merv 13 filters. Checked and flushed out drain lines for each unit. System is operational at this time.


Austin C.

Austin C. Job Checkin

Performed sidekick maintenance. Filter is ok, client will change it himself. Temp drop/rise is within specs. Amp draws are within specs. Tightened and checked all wires, flushed drain line. System is operating properly at this time.


Fidel G.

Fidel G. Job Checkin

Upon arrival my concern was that the upstairs was blowing air while the downstairs only calling for Heat. Went into the attic and found no issues with zone motor. System operational, take 45 seconds to close damper completely. Tested zone board, sending 30.8v to damper motor, can damage zone motors. Operation Voltage should be around 27.5A max. Zone Board will need to be replaced in future. Showed homeowner. Recommendations New HVAC due to conditions, age and efficiency


octavior@hufthomeservices.com

octavior@hufthomeservices.com Job Checkin

Upon arrival found kitchen line backing up. Cabled line through interior cleanout. Wasn’t able to identify source of blockage. Line most likely has grease build up over the years, recommend hydro jetting line. Line clear of blockages tested by filling up sink and draining. Test well.


Bradley M.

Bradley M. Job Checkin

Replaced ARD zone damper motor to allow for proper zoning operation. Tested zoning individually and simultaneously. System is operational at this time.


Ryan M.

Ryan M. Job Checkin

Ran and tested heat cycle. Wired up ECM condenser fan motor correctly. System operational. Explained the noise from compressor was system going into defrost cycle. No charge for today. System operational.


Miguel R.

Miguel R. Job Checkin

Replaced outdoor communicating board. System is operational and heating at this time


Bradley M.

Bradley M. Job Checkin

Checked and cleaned all components. Tightened wiring connections. Upstairs Zone blows air when only downstairs thermostat is making a call for heating/cooling. Zone board is sending power to close damper. Damper motor has failed. Blower capacitor is below spec. Blower motor is leaking oil. Contactor is burnt and pitted. System is currently cooling with a 19° temp split. Both heating and cooling operational. Recommend looking into system replacement due to age/reliability, operating condition/cost of repairs, efficiency and r22 phaseout.


Shuntavious  O.

Shuntavious O. Job Checkin

Preformed furnace tuneup on a Trane and a Rheem system both systems have no air purifier no other issues or concerns at this time both systems are operational


Austin C.

Austin C. Job Checkin

Performed heater maintenance x2. Heat rises are within specs, flushed drain lines. Filters are clean, amp draws and gas pressures are within specs. Cleaned flame sensors and burners. Both furnaces are operational at this time. Recommend: continue maintenance program.


Austin C.

Austin C. Job Checkin

Performed heater maintenance. Heat rise is within specs, changed filter, flushed drain line, amp draws are within specs. Cleaned outdoor coil. Refrigerant pressures are within specs. System is operational at this time. Signed back up on superhero club.


Jet C.

Jet C. Job Checkin

Found Thermostat set to emergency heat. Set thermostat to heat mode. Tested system for operations, system is operating properly at this time.


Miguel R.

Miguel R. Job Checkin

Could not finish maintenance. Heat pump communicating board is bad. Will order a new 1 to replace under parts warranty. Only charging for labor. Signed homeowner up for guardian club membership. System is operational and heating at this time but under auxiliary heat


Miguel R.

Miguel R. Job Checkin

Replaced filter. Lra is over max allowed. All else within specs. System is operational and heating at this time. Signed homeowner up for sidekick club


Andre B.

Andre B. Job Checkin

Pana rival homeowner stated that system was not cooling house properly. Upon diagnosis found capacitor on outdoor unit is bad and system is a little bit low on refrigerant. Replaced capacitor with new capacitor and added 2 1/2 pounds of refrigerant to system. Also washed outdoor unit .System is operational at this time