Responded to no heat service call for 12-year-old natural gas furnace experiencing short cycling. Diagnostic inspection revealed furnace would operate briefly then shut down. Visual examination identified critical failure: heat exchanger with visible hole/burn through, confirmed by photographic documentation. Equipment red-tagged due to safety hazard. Arranged emergency service priority and completed necessary documentation for heat exchanger replacement.
Responded to no-heat call for 5-year-old boiler with ignition failure. Diagnosed air-locked baseboards and non-functional pressure gauge. Purged all baseboard zones to restore proper circulation, successfully restoring heat to the system. Recommended replacement of pressure gauge for continued proper operation.
Diagnosed Goodman furnace with no heat complaint and found failed inducer motor and worn ignition assembly. Replaced both components, restoring proper operation to heating system.
Responded to clogged kitchen sink drainage issue. Upon inspection, found blockage originated beneath concrete slab in basement rather than in under-sink plumbing. Successfully cleared obstruction by running cable through basement cleanout access point, restoring proper drainage function to kitchen sink.
Responded to service call for water pooling under customer's older furnace. Diagnosed overflow issue with condensation pump that had tripped the GFCI. Cleaned the pump thoroughly and reset power to resolve the issue.
Performed routine furnace tune-up on 27-year-old unit with no current operational issues. Replaced 16x20x1 filter as part of standard maintenance protocol. Observed inducer motor exhibiting audible whining and hot surface ignitor (HSI) showing reduced performance; both components were replaced due to age-related wear. Diagnostic readings confirmed proper system operation post-service.
Cleaned out plugged main bath Mansfield toilet, flushed as required.