2930 61st Street
Menomonie, WI 54751
715-283-4422

Our Top Cities


Local Reviews

Rated 4.8 out of 5 stars based on 96 customer reviews

Good New furnace

They install new furnace and it works very well.


Response from Hurlburt Heating & Plumbing:

So happy to hear that you are happy with your new furnace installation! Thank you for leaving a great review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome Price!

They told me exactly what the cost was going to be and they did a great job, perfect! Our new air conditioner and furnace work great!


Response from Hurlburt Heating & Plumbing:

We are so happy to hear that you are please with your new HVAC Installation! We appreciate the review and your business!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always us Hurlburt, Solid People!

My dad always called Hurlburts when I was kid and now I use them!


Response from Hurlburt Heating & Plumbing:

It was a pleasure serving you and your family. We really appreciate you taking the time to share your feedback and leaving such an amazing review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

I've had several of their guys out over the years, they always do a good job.


Response from Hurlburt Heating & Plumbing:

It was a pleasure serving you and your family. We really appreciate you taking the time to share your feedback!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Best Air Conditioner Guys Around!

I hate the heat so I'm not about to take a chance on anyone else. Just call Hurlburt, they know their stuff.


Response from Hurlburt Heating & Plumbing:

Thank you so much for taking the time to leave an excellent rating. We really appreciate your business.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fast Service

They were here in less than 30 minutes, no kidding! The guy had a part with him and our air conditioner is working great again.


Response from Hurlburt Heating & Plumbing:

Thank you so much for taking the time to leave an excellent rating. We really appreciate your business.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Dependable

Always take good care of us.


Response from Hurlburt Heating & Plumbing:

Thank you for sharing your kind words with us. It means the world to us and to our entire team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good


Response from Hurlburt Heating & Plumbing:

Thank you so much for your 5-star review! We will share this with the team to let them know to keep up the amazing work.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fix our Furnace

The air conditioner wasn't working so my neighbor recommended Hurlburt Heating and Plumbing, I called them and they came over the same day. My furnace needed a new motor! They had the part with them and did a really good job of cleaning up when they were done.


Response from Hurlburt Heating & Plumbing:

We are so appreciative for the reference from your neighbor! Glad we could help with your new furnace motor!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Installed a Air Conditioner

They had a great deal going on and our old system was like 30 years old. Can't wait to use this new a/c!


Response from Hurlburt Heating & Plumbing:

Glad to hear your AC installation was a success! Thanks for the great review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fair Price and Professional

They did a good job and didn't over charge us.


Response from Hurlburt Heating & Plumbing:

We are so glad you chose Hurlburt for your plumbing and heating service! Thank you for the amazing review.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fine Job

They did good work.


Response from Hurlburt Heating & Plumbing:

Thank you so much for the great rating!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Help us out

We were out of town and my 19 year old daughter was home alone, of course this is when our heating and cooling system decides to stop working! I did the google thing and there is Hurlburt, called them and they sent a guy right over, done! I liked that the office lady said all of their technicians are drug and background checked since my daughter was home. We'll be using them in the future.


Response from Hurlburt Heating & Plumbing:

We are thrilled that you trusted Hurlburt with your heating repairs! Thanks for the amazing review.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional


Response from Hurlburt Heating & Plumbing:

We’re so glad you had a good experience.

  • Overall Experience
  • Quality
  • Price
  • Convenience

I love Hurlburt!

Everytime I've called they are able to come over pretty quick and fix our stuff. We joined they're club so they come 2 times a year to service our air conditioner and furnace. One time we did have a small issue but they came right back and made it right, thats all I ask.


Response from Hurlburt Heating & Plumbing:

Thanks for all your kind words. Glad we were able to complete your hvac repairs and get you on our maintenance program moving forward!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Logan P.

Logan P. Job Checkin

Diagnosed lukewarm water issue from NTI combi boiler system with Amtrol storage tank. Observed functional components including copper plumbing network, expansion tanks, and proper mechanical connections. Recommended customer proceed with scheduled HVAC technician consultation due to specialized nature of the NTI combi boiler system requiring manufacturer-specific expertise.

Diagnosed lukewarm water issue from NTI combi boiler system with Amtrol storage tank. Observed functional components including copper plumbing network, expansion tanks, and proper mechanical connections. Recommended customer proceed with scheduled HVAC technician consultation due to specialized nature of the NTI combi boiler system requiring manufacturer-specific expertise. Diagnosed lukewarm water issue from NTI combi boiler system with Amtrol storage tank. Observed functional components including copper plumbing network, expansion tanks, and proper mechanical connections. Recommended customer proceed with scheduled HVAC technician consultation due to specialized nature of the NTI combi boiler system requiring manufacturer-specific expertise.

Logan P.

Logan P. Job Checkin

Responded to service call for leaking water heater (10+ years old, original to home). Diagnosed leak originating from stem near gas valve and found T&P valve leaking. Successfully replaced temperature and pressure relief valve to resolve immediate safety concern. Documented system condition with photos showing significant corrosion and mineral buildup in plumbing components. Recommended replacement of aging water heater and addition of expansion tank; customer will review estimate options.

Responded to service call for leaking water heater (10+ years old, original to home). Diagnosed leak originating from stem near gas valve and found T&P valve leaking. Successfully replaced temperature and pressure relief valve to resolve immediate safety concern. Documented system condition with photos showing significant corrosion and mineral buildup in plumbing components. Recommended replacement of aging water heater and addition of expansion tank; customer will review estimate options. Responded to service call for leaking water heater (10+ years old, original to home). Diagnosed leak originating from stem near gas valve and found T&P valve leaking. Successfully replaced temperature and pressure relief valve to resolve immediate safety concern. Documented system condition with photos showing significant corrosion and mineral buildup in plumbing components. Recommended replacement of aging water heater and addition of expansion tank; customer will review estimate options.

Jon W

Jon W Job Checkin

Responded to no heat complaint for aging fan coil boiler system. Upon inspection, determined that all components are functioning correctly, but unit is unable to maintain desired temperature (currently reading 66°F) due to poor thermal envelope. Identified that supply vents are positioned adjacent to drafty window and glass sliding door, causing significant cold air infiltration that reduces heating efficiency. Advised customer that system limitations cannot be overcome without addressing building envelope issues.

Responded to no heat complaint for aging fan coil boiler system. Upon inspection, determined that all components are functioning correctly, but unit is unable to maintain desired temperature (currently reading 66°F) due to poor thermal envelope. Identified that supply vents are positioned adjacent to drafty window and glass sliding door, causing significant cold air infiltration that reduces heating efficiency. Advised customer that system limitations cannot be overcome without addressing building envelope issues. Responded to no heat complaint for aging fan coil boiler system. Upon inspection, determined that all components are functioning correctly, but unit is unable to maintain desired temperature (currently reading 66°F) due to poor thermal envelope. Identified that supply vents are positioned adjacent to drafty window and glass sliding door, causing significant cold air infiltration that reduces heating efficiency. Advised customer that system limitations cannot be overcome without addressing building envelope issues.

Logan P.

Logan P. Job Checkin

Diagnosed Bradford White Defender water heater with no hot water issue. Discovered pressure switch code error and ice-cold blower motor with ice buildup around ports, similar to previous year's problem. Shortened exhaust vent closer to house and installed 90-degree elbow with protective screen. Provided customer with replacement options for pressure switch, blower motor, and complete water heater unit.

Diagnosed Bradford White Defender water heater with no hot water issue. Discovered pressure switch code error and ice-cold blower motor with ice buildup around ports, similar to previous year's problem. Shortened exhaust vent closer to house and installed 90-degree elbow with protective screen. Provided customer with replacement options for pressure switch, blower motor, and complete water heater unit. Diagnosed Bradford White Defender water heater with no hot water issue. Discovered pressure switch code error and ice-cold blower motor with ice buildup around ports, similar to previous year's problem. Shortened exhaust vent closer to house and installed 90-degree elbow with protective screen. Provided customer with replacement options for pressure switch, blower motor, and complete water heater unit.

Jon W

Jon W Job Checkin

Responded to no heat complaint for 12-year-old furnace. Upon inspection, found multiple critical failures including failed inducer motor, oil-leaking blower motor, and control board with visible burn marks. Complete furnace replacement performed due to extent of damage and system age.

Responded to no heat complaint for 12-year-old furnace. Upon inspection, found multiple critical failures including failed inducer motor, oil-leaking blower motor, and control board with visible burn marks. Complete furnace replacement performed due to extent of damage and system age. Responded to no heat complaint for 12-year-old furnace. Upon inspection, found multiple critical failures including failed inducer motor, oil-leaking blower motor, and control board with visible burn marks. Complete furnace replacement performed due to extent of damage and system age.

Mike B.

Mike B. Job Checkin

Diagnosed and resolved no-heat issue on recently installed furnace (3 days prior) by identifying water damage to parlor thermostat. Temporarily relocated thermostat to furnace housing in dry location to restore heating functionality. Completed paperwork for replacement agricultural-grade thermostat to provide proper long-term solution for the environment.

Diagnosed and resolved no-heat issue on recently installed furnace (3 days prior) by identifying water damage to parlor thermostat. Temporarily relocated thermostat to furnace housing in dry location to restore heating functionality. Completed paperwork for replacement agricultural-grade thermostat to provide proper long-term solution for the environment. Diagnosed and resolved no-heat issue on recently installed furnace (3 days prior) by identifying water damage to parlor thermostat. Temporarily relocated thermostat to furnace housing in dry location to restore heating functionality. Completed paperwork for replacement agricultural-grade thermostat to provide proper long-term solution for the environment.

Dan S.

Dan S. Job Checkin

Responded to no-heat call for 1984 Goodman Freedom 80 furnace. Diagnosed ignition failure due to dirty flame sensor. Cleaned flame sensor, restored proper flame signal verification, and confirmed unit operating correctly with multiple test cycles. Customer interested in replacement quote; scheduled follow-up consultation.

Responded to no-heat call for 1984 Goodman Freedom 80 furnace. Diagnosed ignition failure due to dirty flame sensor. Cleaned flame sensor, restored proper flame signal verification, and confirmed unit operating correctly with multiple test cycles. Customer interested in replacement quote; scheduled follow-up consultation.

Logan P.

Logan P. Job Checkin

Responded to service call for a leaking Bradford White 50-gallon natural gas water heater, approximately 10 years old. Diagnostic inspection revealed a pinhole leak on the bottom skirt of the tank, requiring full unit replacement. Successfully installed new A.O. Smith ProMax water heater with proper connections to existing water lines and gas supply.

Responded to service call for a leaking Bradford White 50-gallon natural gas water heater, approximately 10 years old. Diagnostic inspection revealed a pinhole leak on the bottom skirt of the tank, requiring full unit replacement. Successfully installed new A.O. Smith ProMax water heater with proper connections to existing water lines and gas supply. Responded to service call for a leaking Bradford White 50-gallon natural gas water heater, approximately 10 years old. Diagnostic inspection revealed a pinhole leak on the bottom skirt of the tank, requiring full unit replacement. Successfully installed new A.O. Smith ProMax water heater with proper connections to existing water lines and gas supply.

Jon W

Jon W Job Checkin

Responded to no heat call for boiler system. Upon inspection, identified heating failure caused by blockage in ventilation ductwork. Cleared obstruction and applied leak detection tape to monitor potential leak points in galvanized metal ducting. System now operating at normal parameters with proper heat distribution.

Responded to no heat call for boiler system. Upon inspection, identified heating failure caused by blockage in ventilation ductwork. Cleared obstruction and applied leak detection tape to monitor potential leak points in galvanized metal ducting. System now operating at normal parameters with proper heat distribution.

Mike B.

Mike B. Job Checkin

Responded to no heat complaint in upstairs apartment. Diagnosed furnace in attic with continuously running fan but no heat production. Located and repaired loose Molex connection on control board. Tested system operation multiple times with wire movement to verify repair stability. Inspected heat exchanger - no defects found. System now operating properly with heat restored. Advised customer about potential board replacement if issue recurs.

Responded to no heat complaint in upstairs apartment. Diagnosed furnace in attic with continuously running fan but no heat production. Located and repaired loose Molex connection on control board. Tested system operation multiple times with wire movement to verify repair stability. Inspected heat exchanger - no defects found. System now operating properly with heat restored. Advised customer about potential board replacement if issue recurs. Responded to no heat complaint in upstairs apartment. Diagnosed furnace in attic with continuously running fan but no heat production. Located and repaired loose Molex connection on control board. Tested system operation multiple times with wire movement to verify repair stability. Inspected heat exchanger - no defects found. System now operating properly with heat restored. Advised customer about potential board replacement if issue recurs.

Dan S.

Dan S. Job Checkin

Diagnosed furnace with no heat due to seized draft inducer motor and severely rusted burner assembly. Visual inspection revealed significant corrosion throughout system, including suspicious areas on heat exchanger. System approximately 15 years old has reached end of useful life; recommended replacement options rather than repair due to extensive deterioration and age of unit.

Diagnosed furnace with no heat due to seized draft inducer motor and severely rusted burner assembly. Visual inspection revealed significant corrosion throughout system, including suspicious areas on heat exchanger. System approximately 15 years old has reached end of useful life; recommended replacement options rather than repair due to extensive deterioration and age of unit. Diagnosed furnace with no heat due to seized draft inducer motor and severely rusted burner assembly. Visual inspection revealed significant corrosion throughout system, including suspicious areas on heat exchanger. System approximately 15 years old has reached end of useful life; recommended replacement options rather than repair due to extensive deterioration and age of unit.

Jon W

Jon W Job Checkin

Responded to no heat complaint on 20-year-old mobile home furnace. Diagnostic testing revealed failed control board and transformer requiring replacement. Visual inspection identified significant dust accumulation on blower motor and potential crack in heat exchanger. Due to age of unit and critical safety components compromised, recommended complete furnace replacement rather than component repair.

Responded to no heat complaint on 20-year-old mobile home furnace. Diagnostic testing revealed failed control board and transformer requiring replacement. Visual inspection identified significant dust accumulation on blower motor and potential crack in heat exchanger. Due to age of unit and critical safety components compromised, recommended complete furnace replacement rather than component repair. Responded to no heat complaint on 20-year-old mobile home furnace. Diagnostic testing revealed failed control board and transformer requiring replacement. Visual inspection identified significant dust accumulation on blower motor and potential crack in heat exchanger. Due to age of unit and critical safety components compromised, recommended complete furnace replacement rather than component repair.

Roger M.

Roger M. Job Checkin

Responded to customer call regarding furnace exhibiting error code 57 (pressure switch stuck open). Upon arrival, the unit was operational with no apparent issues. Performed diagnostic testing on flame sensor and inducer motor amperage, both of which tested within normal parameters. Noted that customer had recently replaced the filter. Visual inspection of internal components revealed no abnormalities or blockages. No repair was necessary as system was functioning properly at time of service.

Responded to customer call regarding furnace exhibiting error code 57 (pressure switch stuck open). Upon arrival, the unit was operational with no apparent issues. Performed diagnostic testing on flame sensor and inducer motor amperage, both of which tested within normal parameters. Noted that customer had recently replaced the filter. Visual inspection of internal components revealed no abnormalities or blockages. No repair was necessary as system was functioning properly at time of service. Responded to customer call regarding furnace exhibiting error code 57 (pressure switch stuck open). Upon arrival, the unit was operational with no apparent issues. Performed diagnostic testing on flame sensor and inducer motor amperage, both of which tested within normal parameters. Noted that customer had recently replaced the filter. Visual inspection of internal components revealed no abnormalities or blockages. No repair was necessary as system was functioning properly at time of service.

Dan S.

Dan S. Job Checkin

Diagnosed and serviced in-floor heating system that was failing to operate properly. Found zone valve at boiler was seized in closed position, preventing proper flow to garage zone. Applied lubricant to free the seized valve stem and manually exercised component until proper operation was restored. Tested system functionality and confirmed heat delivery resumed to garage floor system. Customer advised that replacement of zone valve plunger assembly may be necessary if issue recurs.

Diagnosed and serviced in-floor heating system that was failing to operate properly. Found zone valve at boiler was seized in closed position, preventing proper flow to garage zone. Applied lubricant to free the seized valve stem and manually exercised component until proper operation was restored. Tested system functionality and confirmed heat delivery resumed to garage floor system. Customer advised that replacement of zone valve plunger assembly may be necessary if issue recurs.

Mike B.

Mike B. Job Checkin

Responded to no heat call for 10-year-old Ruud furnace displaying error code 45. Diagnosed faulty pressure switch causing system failure, contradicting previous company's assessment of needing circuit board and valve replacements. Attempted temporary repair with universal Cleveland switch but determined it was unreliable. System currently operational, but requires installation of correct OEM pressure switch to ensure proper long-term function.

Responded to no heat call for 10-year-old Ruud furnace displaying error code 45. Diagnosed faulty pressure switch causing system failure, contradicting previous company's assessment of needing circuit board and valve replacements. Attempted temporary repair with universal Cleveland switch but determined it was unreliable. System currently operational, but requires installation of correct OEM pressure switch to ensure proper long-term function. Responded to no heat call for 10-year-old Ruud furnace displaying error code 45. Diagnosed faulty pressure switch causing system failure, contradicting previous company's assessment of needing circuit board and valve replacements. Attempted temporary repair with universal Cleveland switch but determined it was unreliable. System currently operational, but requires installation of correct OEM pressure switch to ensure proper long-term function.