Conducted tune-up on 19-year-old FA furnace including inspection of venting, exhaust flue, heat exchanger (via camera), burners, blower, inducer, pressure switches, safety and limit switches, flame sensor and igniter. Verified gas pressures, combustion air, and system cycling. Found high resistance in ignitor and noisy inducer operation requiring replacement. System currently operating normally despite these issues.
Responded to no-heat service call for 20+ year old forced air furnace that was only producing clicking sounds. Diagnostic inspection revealed failed inducer motor. Due to equipment age and component failure, recommended and completed replacement of entire unit rather than repairing the obsolete system.
Performed AC tune-up on Lennox system and discovered two significant issues: refrigerant leak with low R22 levels and a cracked heat exchanger with missing igniter. Recommended full system replacement due to age of equipment and safety concerns with the compromised heat exchanger.
This system is operating well with no issues. The homeowner wasn’t sure the heat pump was programmed right and wanted to be sure it was. He is going to have excel come and retrieve the saver switch that is unhooked.