Roger M.

Roger M. Job Checkin

Completed replacement of failed inducer draft fan motor on furnace unit. Sourced replacement part from Johnstone Bloomington and installed new component to restore proper system operation. Visual inspection confirmed correct installation of all connections and proper functioning of the replaced assembly.

Completed replacement of failed inducer draft fan motor on furnace unit. Sourced replacement part from Johnstone Bloomington and installed new component to restore proper system operation. Visual inspection confirmed correct installation of all connections and proper functioning of the replaced assembly.

Roger M.

Roger M. Job Checkin

Completed installation of replacement inducer draft fan motor in customer's HVAC system. Existing unit showed signs of age with visible wear and discoloration on surrounding components. Parts were sourced from Johnstone supply and installation was completed successfully within the one-hour timeframe as estimated on the sold repair.

Completed installation of replacement inducer draft fan motor in customer's HVAC system. Existing unit showed signs of age with visible wear and discoloration on surrounding components. Parts were sourced from Johnstone supply and installation was completed successfully within the one-hour timeframe as estimated on the sold repair.

Tim M.

Tim M. Job Checkin

Diagnosed water leak at base of 14-15 year old 50-gallon water heater. Determined tank was rusting out, causing leakage. Replaced aging water heater with new Bradford White unit, installed all necessary copper supply lines and ventilation components, and verified proper operation of the new system.

Diagnosed water leak at base of 14-15 year old 50-gallon water heater. Determined tank was rusting out, causing leakage. Replaced aging water heater with new Bradford White unit, installed all necessary copper supply lines and ventilation components, and verified proper operation of the new system. Diagnosed water leak at base of 14-15 year old 50-gallon water heater. Determined tank was rusting out, causing leakage. Replaced aging water heater with new Bradford White unit, installed all necessary copper supply lines and ventilation components, and verified proper operation of the new system.

Gary L.

Gary L. Job Checkin

Responded to no heat call for 26-year-old modular home furnace. Diagnostic testing revealed seized inducer motor preventing ignition sequence. Ordered replacement inducer motor part to restore heating functionality.

Responded to no heat call for 26-year-old modular home furnace. Diagnostic testing revealed seized inducer motor preventing ignition sequence. Ordered replacement inducer motor part to restore heating functionality. Responded to no heat call for 26-year-old modular home furnace. Diagnostic testing revealed seized inducer motor preventing ignition sequence. Ordered replacement inducer motor part to restore heating functionality.

Jared R.

Jared R. Job Checkin

Performed comprehensive fall tune-up on 15-year-old forced air gas furnace. Service included inspection of heat exchanger via camera, verification of all safety components (pressure switch, limit switches, flame sensor, igniter), and testing of gas pressures and combustion air. System cycled successfully on both high and low settings, confirming proper operation with no issues detected.

Performed comprehensive fall tune-up on 15-year-old forced air gas furnace. Service included inspection of heat exchanger via camera, verification of all safety components (pressure switch, limit switches, flame sensor, igniter), and testing of gas pressures and combustion air. System cycled successfully on both high and low settings, confirming proper operation with no issues detected. Performed comprehensive fall tune-up on 15-year-old forced air gas furnace. Service included inspection of heat exchanger via camera, verification of all safety components (pressure switch, limit switches, flame sensor, igniter), and testing of gas pressures and combustion air. System cycled successfully on both high and low settings, confirming proper operation with no issues detected.

Jarrod S.

Jarrod S. Job Checkin

Successfully cut and capped water supply lines in kitchen during ongoing renovation. Removed existing plumbing connections and installed appropriate caps on water lines to ensure no leakage while maintaining proper drainage system functionality.

Successfully cut and capped water supply lines in kitchen during ongoing renovation. Removed existing plumbing connections and installed appropriate caps on water lines to ensure no leakage while maintaining proper drainage system functionality. Successfully cut and capped water supply lines in kitchen during ongoing renovation. Removed existing plumbing connections and installed appropriate caps on water lines to ensure no leakage while maintaining proper drainage system functionality.

Craig M.

Craig M. Job Checkin

For today visit, I check on a 6 years old air conditioning. Performing a thorough inspection and maintenance of the system to ensure it is running efficiently. Checked the electrical connections ensure it’s clear and functioning correctly. Cleaned out the condenser coils, inspecting fan blades and motor, and checked the thermostat to ensure it is calibrated correctly. Cleaned condensation line making sure it’s draining properly. As always thank you for choosing Hurlburt Heating and Cooling.