David B. Job Checkin

CCC AC tuneup -prepaid Air conditioner preventive maintenance Check filters, Check contactors and capacitors, check all motors including compressor. Check refrigerant charge and temps in system. Pull covers and clean condenser coil. All checks good at this time. Daikin Age of unit 2015 Refrigerant R410A on TXV Outdoor temp. 46 degrees Capacitor 45/5 Actual 44.5/5.1 Compressor amps. 4.2 Condenser fan motor 0.6 amps Charge is good Daikin Age of unit 2016 Refrigerant R410A on TXV Outdoor temp. 56 degrees Capacitor 35/5 Actual 34.2/4.8 Compressor amps. 4.6 Condenser fan motor 0.6 amps Charge is good Daikin Age of unit 2015 Refrigerant R410A on TXV Outdoor temp. 46 degrees Capacitor 30/5 Actual 29.5/4.6 Compressor amps. 3.8 Condenser fan motor 0.6 amps Charge is good We now offer generator installation, service, and repair Have a great summer, Dave


David B.

David B. Job Checkin

Estimate to run 30 amp 240 V circuit to porch for sauna.