David B.

David B. Job Checkin

I will email owners pricing system repairs, and have Dave quote them pricing for a mini split

I will email owners pricing system repairs, and have Dave quote them pricing for a mini split

David B.

David B. Job Checkin

Full system install (180 flip) & water heater install

Full system install (180 flip) & water heater install

David B.

David B. Job Checkin

Customer had a “replace filter” reminder. Cleared and reset


David B.

David B. Job Checkin

Service professional arrived to provide an estimate for an unknown drain pipe. Upon arrival, the service professional was shown in the basement where water was seeping in through a crack in the floor as well as from the foundation. The service professional recommended that the homeowner find a foundation specialist and have an inspection of their drain tile. It is possible that the in floor drain pipe from the kitchen sink is contributing to the water seepage. No estimates given at this time.


David B.

David B. Job Checkin

Upon arrival spoke with customers daughter about current issues. Said heat has not been working since last night. Looked at thermostat and found stat set to off. Turned to heat and made sure set point was abouve inside temp (setpoint was 70° and current temp was 61°). Went to furnace, fired up right away, checked filter checked and adjusted gas pressures and made sure furnace kicked into high fire. Once high fire kicked in I turned furnace off and checked dip switches. Brought furnace back on and checked components to make sure everything was functioning normal. No further issues, only problem was thermostat was not set to heat.


David B.

David B. Job Checkin

Inducer replacement

Inducer replacement

David B.

David B. Job Checkin

Service professional came out to assess a leaking water heater. The water heater will need to be replaced. An estimate was provided. Homeowner mentioned the furnace and ac are older and they might want to replace at the same time.

Service professional came out to assess a leaking water heater. The water heater will need to be replaced. An estimate was provided. Homeowner mentioned the furnace and ac are older and they might want to replace at the same time.

David B.

David B. Job Checkin

Upon arrival found zone valve head bad motor was slipping and would not open valve properly. Replaced Erie pop top head and operation of the zone is normal.


David B.

David B. Job Checkin

Cleaned out soot. Electrodes spaced properly. Adjusted air shutters. Clean smoke test. Unit has to have yearly tune ups to keep warranty active and to keep unit running efficiently. Cycled. All ok


David B.

David B. Job Checkin

Replaced inducer

Replaced inducer

David B.

David B. Job Checkin

Furnace running, customer had fan set to on and was feeling room temperature air coming out of vents.


David B.

David B. Job Checkin

Had limit and flame sensor codes. Filter was replaced. I cleaned the flame sensor. Tested Ignitor. All good now.

Had limit and flame sensor codes. Filter was replaced. I cleaned the flame sensor. Tested Ignitor. All good now.

David B.

David B. Job Checkin

Found a noisy blower motor. Part is ordered. Call to schedule when it arrives. Has heat for now, just noisy on start up and shutdown.


David B.

David B. Job Checkin

Upon arrival I found ignitor cracked. When I replaced the ignitor I found the circuit board not sending 24 volts to gas valve. When I recycled unit on to test again it would turn main fan on and not inducer. Replaced main circuit board and tested unit again and operation of the unit is normal. I cycled unit several times and tested other safeties and everything was good. We discussed new unit but they are potentially selling home soon and wanted to repair current system. Payment received

Upon arrival I found ignitor cracked. When I replaced the ignitor I found the circuit board not sending 24 volts to gas valve. When I recycled unit on to test again it would turn main fan on  and not inducer. Replaced main circuit board and tested unit again and operation of the unit is normal. I cycled unit several times and tested other safeties and everything was good. We discussed new unit but they are potentially selling home soon and wanted to repair current system. Payment received

David B.

David B. Job Checkin

House has hydronic copper fin tube baseboard heaters. Piping froze and split. House is to be gutted, replace baseboard heaters throughout. Condition of the remainder of the existing copper piping is unknown. Boiler is a newer high efficiency Triangle Tube. The condition of the boiler is unknown at this time. Will need to be drained for winter.