They were here in less than 30 minutes, no kidding! The guy had a part with him and our air conditioner is working great again.
Response from Hurlburt Heating & Plumbing:
Thank you so much for taking the time to leave an excellent rating. We really appreciate your business.
Overall Experience
Quality
Price
Convenience
A friend recommended Hurlburt Heating & Plumbing when we needed a new furnace and air conditioner. We couldn't be happier. Andrew came out to our house and gave us a couple different options, he answered all my wifes questions and then we scheduled the installation all at the same time. 2 days later, we have a whole new central air conditioning and furnave system. Oh, and they even finaced it for 18 month with nothing out of pocket. I like using other peoples money. :)
Response from Hurlburt Heating & Plumbing:
We're thrilled to hear that you enjoyed your experience with us. Thanks for the kind words!
Overall Experience
Quality
Price
Convenience
Responded to no-heat call for 20+ year old furnace system. Diagnosed failed smart valve and leaking combustion blower. Customer declined repair due to cost and age of unit, opted for complete furnace replacement. Coordinated with advisor for replacement options.
Completed warranty service replacing failed inducer motor on Myers Source furnace. Upon testing, identified excessive vibration in blower wheel during high-speed operation. Warranty claim form submitted for replacement blower wheel to resolve secondary issue.
Responded to service call for lounge furnace and overhead unit heater issues. Diagnosed and replaced failed blower motor in lounge furnace, restoring heat functionality. Performed assessment on overhead unit heater above boiler room which requires combustion blower replacement; customer approved repair for furnace motor only.
Diagnosed newly installed LP furnace failing to function as backup to insufficient geothermal system. Identified ground fault issue and installed temporary jumper wire to restore geothermal operation. Inspected motor assembly, blower components, and electrical junction box connections to ensure proper system functionality.
Responded to no heat call for 19-year-old furnace that was in lockout mode. Diagnosed issue by following manual troubleshooting steps, identifying extremely dirty flame sensor as the root cause. Cleaned sensor component thoroughly, purged air from system, and verified proper operation. System is now functioning correctly. Recommended equipment upgrade due to age, and scheduled comfort advisor consultation.
Responded to no heat call for Goodman GMVC960804CNAA furnace (manufactured 2015). Diagnosed locked combustion blower as the source of failure. Removed front panel, accessed internal components, and replaced combustion blower to restore proper operation. Enrolled customer in rewards membership program. Unit now functioning correctly with heat restored.
Installed new standard height toilet with round bowl. Replaced wax ring and bolts during installation. Completed basic installation according to industry standards.
Performed comprehensive tune-ups on two furnaces in newly purchased property. First unit (older, smaller) was functioning properly with clean filter and blower, clear routine lines, and intact heat exchanger. Second unit (newer, larger) showed signs of secondary heat exchanger leakage; adjusted furnace pitch by an additional 1/8 inch to correct the issue. Both systems demonstrated proper operation during 15-minute test runs with appropriate temperature rises (70° and 60° respectively). Recommended AC inspection in spring.
Performed scheduled HVAC maintenance including filter replacement and comprehensive system inspection of geothermal units, checking pressures and temperatures. Identified and temporarily repaired oxygen airline leak, with customer arranging for replacement part from oxygen supplier. Documented failed exhaust fan in cat room requiring blower motor and wheel replacement; submitted parts request form for future service visit.
Responded to a callback regarding humidifier operation and outdoor unit panel issues from previous service. Adjusted thermostat parameters to enable humidifier operation in heat mode and increased window protection settings. Identified and repaired a leak in the humidifier system. Confirmed proper humidifier functionality after repairs and adjustments.
Performed scheduled preventative maintenance on 1-year-old furnace system. Conducted comprehensive inspection with all operational parameters testing within manufacturer specifications. No issues detected with furnace or related electrical components. System is functioning properly and ready for normal operation.
Diagnosed and serviced 20-year-old Eljer toilet with persistent running issue. Observed significant mineral buildup around pipe connections and flapper mechanism that was intermittently functioning. Removed and replaced with new tall round toilet as requested by customer, ensuring proper installation and function before completion.
Responded to no-heat call for shop heater. Diagnostic inspection revealed damaged neutral wire where incoming power connector had been rubbing against inducer wheel, preventing unit from receiving power. Installed 14-gauge wire to replace damaged section, restored power to unit. System now operating correctly with proper heating function.
Performed comprehensive tune-up maintenance on customer's boiler system. Inspected heat exchanger (clean condition), cleaned condensate trap and ignition rod, and verified proper operation of circulation pumps, expansion tank, and thermostat. All systems functioning correctly with no issues identified.
Replaced humidifier canister on Honeywell steam humidifier system. Removed old canister, installed new replacement unit, secured all connections and verified proper operation. System is now functioning correctly with no issues.