Mike B.

Mike B. Job Checkin

Provided technical assistance to Mike R for repair of tube heaters. Performed necessary service work to restore functionality on both units that were down. Replacement parts were installed as documented in Meno, requiring two technicians and ladder access for proper installation and commissioning.

Provided technical assistance to Mike R for repair of tube heaters. Performed necessary service work to restore functionality on both units that were down. Replacement parts were installed as documented in Meno, requiring two technicians and ladder access for proper installation and commissioning.

Liam D.

Liam D. Job Checkin

Responded to wood boiler system operating issue with zones not shutting off at temperature. Diagnosed wood stove lockout and reset unit to restore operation. Examined pump functionality throughout system and replaced garage pump as troubleshooting measure. Identified design issue causing continuous flow through hot water coil loop even when pump is inactive. Recommended installation of relay-in-a-box (RIB) to allow proper thermostat control of blower and pump to eliminate persistent heat problem.

Responded to wood boiler system operating issue with zones not shutting off at temperature. Diagnosed wood stove lockout and reset unit to restore operation. Examined pump functionality throughout system and replaced garage pump as troubleshooting measure. Identified design issue causing continuous flow through hot water coil loop even when pump is inactive. Recommended installation of relay-in-a-box (RIB) to allow proper thermostat control of blower and pump to eliminate persistent heat problem. Responded to wood boiler system operating issue with zones not shutting off at temperature. Diagnosed wood stove lockout and reset unit to restore operation. Examined pump functionality throughout system and replaced garage pump as troubleshooting measure. Identified design issue causing continuous flow through hot water coil loop even when pump is inactive. Recommended installation of relay-in-a-box (RIB) to allow proper thermostat control of blower and pump to eliminate persistent heat problem.

Liam D.

Liam D. Job Checkin

Responded to no-heat call for one-year-old boiler showing error code. Discovered dead bird obstructing venting and condensate system, requiring disassembly of equipment for removal and thorough flushing. Noted minor dripping from relief valve during operational verification after service was completed.

Responded to no-heat call for one-year-old boiler showing error code. Discovered dead bird obstructing venting and condensate system, requiring disassembly of equipment for removal and thorough flushing. Noted minor dripping from relief valve during operational verification after service was completed. Responded to no-heat call for one-year-old boiler showing error code. Discovered dead bird obstructing venting and condensate system, requiring disassembly of equipment for removal and thorough flushing. Noted minor dripping from relief valve during operational verification after service was completed.

Mike B.

Mike B. Job Checkin

Responded to no-heat call at fire station regarding non-functional tube heater. Discovered previous contractor had abandoned the repair job, leaving missing parts on one burner and holes in the tubes. System appears to be an older model with significant wear. Coordinated with team member to evaluate replacement options, including pricing for a new unit heater and researching parts availability for the existing system.

Responded to no-heat call at fire station regarding non-functional tube heater. Discovered previous contractor had abandoned the repair job, leaving missing parts on one burner and holes in the tubes. System appears to be an older model with significant wear. Coordinated with team member to evaluate replacement options, including pricing for a new unit heater and researching parts availability for the existing system. Responded to no-heat call at fire station regarding non-functional tube heater. Discovered previous contractor had abandoned the repair job, leaving missing parts on one burner and holes in the tubes. System appears to be an older model with significant wear. Coordinated with team member to evaluate replacement options, including pricing for a new unit heater and researching parts availability for the existing system.

Mike B.

Mike B. Job Checkin

Performed comprehensive tuneup on Luxaire gas furnace for new customer. Thoroughly inspected heat exchanger with no defects found, cleaned condensate system and burners, and verified proper operation. Noted outdoor Guardian AC unit requires leveling; customer will schedule AC service in spring when weather permits.

Performed comprehensive tuneup on Luxaire gas furnace for new customer. Thoroughly inspected heat exchanger with no defects found, cleaned condensate system and burners, and verified proper operation. Noted outdoor Guardian AC unit requires leveling; customer will schedule AC service in spring when weather permits. Performed comprehensive tuneup on Luxaire gas furnace for new customer. Thoroughly inspected heat exchanger with no defects found, cleaned condensate system and burners, and verified proper operation. Noted outdoor Guardian AC unit requires leveling; customer will schedule AC service in spring when weather permits.

Mike B.

Mike B. Job Checkin

Completed maintenance service on 5-year-old gas furnace. Performed comprehensive tune-up including inspection of heat exchanger, flame sensor cleaning, and condensate system cleaning. Observed corrosion on metal components and examined ductwork connections. Customer reported issues with M30 WiFi thermostat, but opted to continue using current unit after consultation.

Completed maintenance service on 5-year-old gas furnace. Performed comprehensive tune-up including inspection of heat exchanger, flame sensor cleaning, and condensate system cleaning. Observed corrosion on metal components and examined ductwork connections. Customer reported issues with M30 WiFi thermostat, but opted to continue using current unit after consultation. Completed maintenance service on 5-year-old gas furnace. Performed comprehensive tune-up including inspection of heat exchanger, flame sensor cleaning, and condensate system cleaning. Observed corrosion on metal components and examined ductwork connections. Customer reported issues with M30 WiFi thermostat, but opted to continue using current unit after consultation.

Mike B.

Mike B. Job Checkin

Replaced collector box/cold end header box and blower wheel on furnace per approved repair estimate. All components were installed according to manufacturer specifications and system operation was verified to be functioning properly upon completion of work.

Replaced collector box/cold end header box and blower wheel on furnace per approved repair estimate. All components were installed according to manufacturer specifications and system operation was verified to be functioning properly upon completion of work.

Robert J.

Robert J. Job Checkin

AC Repair: I corrected a loud, vibrating AC unit by identifying and securing a loose fan blade that had been causing imbalance. After balancing the fan and inspecting the motor shaft, the system returned to smooth, quiet operation.


Ethan S.

Ethan S. Job Checkin

Air Purification Installation: I installed a high-efficiency, whole-home air purification system integrated directly into the HVAC ductwork. The unit featured HEPA filtration and UV-C sterilization, significantly reducing airborne allergens, mold spores, and bacteria for healthier indoor air.


Andrew E.

Andrew E. Job Checkin

Electrical Repairs: Installed a dedicated 240V circuit with upgraded wiring and a new breaker to support high-demand laundry appliances. This installation prevented circuit overload, ensured consistent operation, and improved the safety and capacity of the home's electrical infrastructure.


Mike B.

Mike B. Job Checkin

-

- -

Dan S.

Dan S. Job Checkin

AC System Repair Service: A homeowner’s AC system was struggling to cool their space effectively. Our inspection revealed a dirty evaporator coil hindering heat exchange. We performed a professional coil cleaning, restoring optimal cooling performance and improving overall system efficiency.


Greg M.

Greg M. Job Checkin

Whole Home Generator Installation: Recognizing the homeowner’s concern about potential power outages, I performed a full assessment of their electrical needs. After carefully selecting a generator that matched the home's power requirements, I proceeded with installation, ensuring seamless integration with the existing electrical system. The project was executed with precision, guaranteeing a reliable backup power supply for uninterrupted electricity during outages.


Ernie S.

Ernie S. Job Checkin

Whole-Home Generator Installation: Concerned about potential power outages, a client sought a dependable backup power solution. I installed a robust whole-home generator tailored to their needs. This comprehensive service included integrating the generator with their electrical system and conducting rigorous tests to ensure automatic activation during outages, providing the homeowner peace of mind and uninterrupted power.


Andrew E.

Andrew E. Job Checkin

Sump Pump Repair Service: During routine maintenance, we discovered that the homeowner's sump pump was not functioning due to a clogged inlet screen, which could result in basement flooding during heavy rain. We cleaned the screen, checked the discharge pipe for blockages, and tested the system to ensure it was working properly. By addressing these issues, we ensured that the client's home remained dry and protected during rainy autumn days.