Diagnosed and replaced faulty pressure switch on one-year-old A.O. Smith water heater that was causing no hot water condition. Part was replaced under warranty, restoring proper operation of the unit.
Inspected deteriorated toilet mechanism exhibiting significant mineral deposits and staining. Diagnosed faulty handle and flapper causing toilet malfunction. Successfully installed new toilet handle and flapper assembly, restoring proper flushing functionality.
Responded to no heat complaint on 22-year-old Rheem Classic 90 Plus furnace. Diagnosed pressure switch fault caused by insect debris blocking condensate drain, which was cleared to restore proper operation. Performed preventative maintenance including flame sensor cleaning and heat exchanger inspection, and advised customer to remove exterior exhaust screen to prevent potential ice buildup during cold weather.
Responded to no-heat call for a 7-year-old Comfort Maker high efficiency furnace. Determined issue was due to power switch being turned off during home inspection. Restored power to unit, performed system check, and verified furnace is now operating normally.
Responded to customer request to disconnect wood boiler from residence. Performed assessment and documentation of existing system, taking detailed measurements of relevant components and piping. Submitted part order form to prepare quote for complete disconnection service as requested by customer.
Responded to no-heat call for furnace. Observed system attempting normal ignition sequence but failing to light. Detected gas odor in home. Inspection of LP tank revealed it was completely empty. Notified homeowner that LP delivery is required for system to operate. Furnace appears to be in normal working condition and should function properly once fuel is supplied.
Responded to customer request to cap off propane gas line that previously fed stove. Safely disconnected and capped line at shutoff valve while maintaining proper gas supply to boiler and water heater in same room. Verified no leaks at capped connection point.
Removed existing boiler mate and installed new 30-gallon electric water heater as requested by customer. Cut and capped boiler side lines and completed all necessary connections to ensure proper functionality of the new unit.
Completed scheduled maintenance on 27-year-old furnace as part of Rewards program. Inspected heat exchanger finding no defects, verified overall system operation, and assessed customer concern about cooling fan cycling which appears to be normal speed shifting during fan-on mode. Customer already has advisor scheduled today for replacement system estimate due to equipment age.