Have any feedback for us? We'd love to hear it! Call us at (760) 910-7600 and let us know how we are doing.
My experience with Daniel Galvan was excellent. He was prompt, friendly, polite, and very knowledgeable. He answered all of my questions and explained things thoroughly.
Frank was professional, friendly and efficient. Many thanks!
Truly appreciated the prompt service I received today Your technician was very knowledgeable and polite
Chris Jones is personable professional and competent.
Daniel was professional and explained things I needed to know clearly and patiently. As always Hydes provides the best professional service. There is none better...
Thor was great today, and helped quickly resolve the issue of my air conditioner line being clogged. He quickly expressed it from the line outside as well as inside showed me pictures. He took and explained that he would put this in my notes for future service calls.
Alex was fantastic ! Very customer friendly and efficient! I want him on all my service calls.
Hyde’s/Jonathan is always there when needed. Much appreciated.
Very efficient and explained what needs to be done
Great job, excellent communication and scheduling. So glad that we went with Hydes! Thank you!
Hydes technician Daniel Galvan is friendly, professional, and an excellent communicator. Upon arrival he explained what the inspection would cover, and he answered several questions. Once Daniel completed his inspection he explained the results and what they meant. A+ Service
Found blower motor failed. Verified voltage to motor. Advised client will order motor Monday and will call him. Gave rough quote on motor.
Executed a cooling maintenance on a split system. Upon arrival, condensate P-trap was clogged, causing condensation to backfill into unit. Cleared condensate drain line and installed float safety switch – paid via C. C. Refrigerant circuit diagnostic – good. No alerts or notifications on CDA. Replace filter and wash down condenser coil. System is cooling the home at the time of maintenance.
Came to property to replace fixtures and device covers after completion of stucco. Also replaced two faulty landscape lights that were previously worked on by other techs.
Performed a cooling maintenance on two R22 York condenser unit. Check sequence of operations by checking out all electrical and refrigeration levels. Was getting a 25° split for both units run capacitor on bedroom unit was low advised on replacing client agreed. At this time, both systems are cooling down the house to the best of their abilities both reaching 78° at lowering. Informed client about the age and condition of units as well as R22. Signed client up with hydes family plan. Paid by client need to call homeowner to get payment for run capacitor finish maintenance by washing down both units and by changing out filters.
Performed a cooling maintenance on a newly installed split system unit as well as prepared for final inspection. System is cooling down the house within manufacture specification. We need to come back and change out breaker currently 50 need to downsize to a 25. After doing so system will be ready for final inspection.
Performed annual cooling maintenance on 2) 2020 Trane XR heat pumps and a 2020 Trane heat pump package unit. Replaced 14x20, 12x24, and 16x25 filters located in the house lower walls and garage filter rack. Followed sequence of operations and checked voltage, amperage, capacitor, temperature splits, Freon levels, cleared condensation lines, and rinsed condenser coils. Ecobee thermostats checked out operational. All systems are working properly in cooling at this time of service.
Comfort ac service on 2011 Goodman upflow split system. Fau located inside the garage, condenser on south side of home. Replaced filter, flushed condensate line and washed coils. Checked all ac components and temperature split. Client showed video on condenser fan motor noise. Advised motor is showing signs of failing with that noise. Advised on age and life expectancy. Sent over replacement estimates. Signed up on yearly agreement.
Micro channel systems check cooling and electrical components everything is working properly a time of service
Wash condenser check cooling and electrical components everything is working properly at time of service
20/20 filter check cooling and electrical components capacitor and compressor saver are within range everything else working properly at time of service
Performed a cooling maintenance on two split systems. Unit #R21F dual run capacitor measured outside of manufacture specifications, due to excessive ambient heat. Estimate sent to replace capacitor under parts warranty – labor not covered. Measured running and starting amperage on all motor motors. Cleared condensate drain line and replaced filters. Refrigerant circuit diagnostic – good. Both systems are cooling the home at the time of maintenance.
Comfort ac service on (2)2011 split systems. Fau located inside closets, condensers on south side of home. Replaced filters on lower walls and 8’ ceiling need drill. Checked all ac components and charge. Blew out electrical compartment. Found systems LRA above rated specifications, recommend hard start kits. Found living area systems capacitor rated 45/10 outside its range. Called client to go over issues. Advised on age and life expectancy. Client to hold off till the fall, sent estimates.