Have any feedback for us? We'd love to hear it! Call us at (760) 910-7600 and let us know how we are doing.
Fred put up my sconces super quick and then troubleshooted another electrical problem. Fantastic service!
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
I appreciated the excellent service from Hydes. I called for an AC check when I noticed a technician was on site performing work for a neighbor. The office accommodated me and the tech stopped by after he completed the neighbors service.
Response from Hydes Air Conditioning:
Thanks so much!
Overall Experience
Quality
Price
Convenience
Elihu was fantastic as usual. I am very happy with Hydes
Overall Experience
Quality
Price
Convenience
Thor was the best tech Hyde’s has sent. So many have felt like “hustlers” looking for commissions. Thor was honest and fair.
Overall Experience
Quality
Price
Convenience
Always so polite and professional. Thorough service.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
This was a service call for a tune up on an older unit. Jonathan was knowledgeable, friendly and helpful.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Fred is a great guy and did a very good job for us. I am completely happy even though he wouldn’t stay for a beer at the end of the day!
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Alert 6 flashes pressure switch aka burner pressure switch open. Equipment runs for min then kicks off. Adjusted gas pressure to 3.5 and same issue. Once flame starts very odd combustion sound in burner compartment. Checked burner compartment for air gap. Verified air intake is clear. Bypassed pressure switch and unit runs though very loud combustion inside burner box. Contacted Jim at us air. Will follow up Tuesday once we have information from tech support.
Hung three exterior sconces as per customer, but as I was finishing up he stated the he lost power to half his house. Once sconces were completed, I proceeded to perform a diagnostic on non op outlets/lights. Found that gfci on back porch was protecting the circuit and was not resetting. Put load wires on line side of gfci and replaced gfci to restore power and resolve issue. Customer stated that we can send him quote for landscape lighting at our convenience.
Installing 4 Ton York ton 13.4 SEER Gas Package unit and 37 Gallon lowboy hot water heater including outdoor electrical box.
Performed annual heating maintenance on a 2025 American Standard heat pump package unit. Replaced 20x25 filter located in hallway ceiling. No ladder is needed. Followed sequence of operations and checked voltage, amperage, capacitor, temperature rise, Freon levels, and secured all electrical connections. Client stated unit made a loud vibrating sound at start up but hasn’t done so recently, cycled equipment and noise was to normal operating standards. Informed client of iso pads and possible seismic springs if noise persists. Nest thermostat checked out okay. System is working properly in heating at this time of service. Scheduled cooling maintenance with client on site.
Performed annual heating maintenance on a 2017 Goodman package unit. Replaced 14x24 filter located in hallway ceiling. Drill needed. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. Checked capacitor and hard start kit. Thermostat checked out operational. System is working properly in heating at this time of service.
Dropped off permit and verified equipment is ready for inspection.
Emailed estimate with Hyde's promotion of free ductless heat pump.
Inspected guest room for mini split installation. Documented everything with photos. Home has 2 split systems, micro channel condensers in front yard, upflow furnaces in garage closet. Spoke with daughter Susan. Informed her systems are older, have refrigerant issues, and will have one of the owners/Hydes brothers to reach out. Email and phone call. She stated she’s in Portland and sometimes not available so email and phone call will be good to go over options. Parents and caregiver are at residence so in person estimate won’t work and to go with email and phone call. Per my findings, systems should be replaced, and mini split looks feasible to install for guest room.
Dropped off permit for inspection. Replaced 50amp breaker and fuses down to a 40amp to match max rated amps on data plate. System is up to code and ready for inspection.
Arrived at customer’s home to label panel to get ready for final inspection. Went through all circuits in home and labeled them accordingly based on what they control.
Performed annual maintenance in heat on 2 carriers one horizontal other up flow , followed Sequence of operation Changed filters checked amps voltage blower motor capacitors limit switches safety switches working at range cleared burners cycled burners cleared condensation lines units are working to manufacture specification in heat
Maintenance for heat on an American standard silver series up low-key pump filter 20 x 23 put sideways underneath FAU FAU located in a closet outside in front of the condensing unit. Check systems of operation checked all electrical safety cleared condensation line checked outside unit check compressor ramps, checked fan motor, check capacitor, check Freon and pressure system is working per manufacture specifications. Office is heating properly.
Performed annual maintenance in heat on one temp star ultra low nox and Bryant up flows location garage, followed Sequence of operation Changed both 20x25 filters in furnace, checked amps voltage limit switches safety switches working at range cleared burners cycled burners units are working to manufacture specification in heat, upon arrival temp star unit last 4 9266 was going off on high limit reset limit tested if it happens again we will order part , filters where dirty recommend reme halos sent estimate, installed water safety switches and Jone valves to prevent water damage if water backs up
Performed annual maintenance in heat on 2 Goodman up flows location hallway closet, followed Sequence of operation Changed filters checked amps voltage limit switches safety switches blower motor capacitors working at range cleared burners cycled burners cleared condensation lines, units are working to manufacture specification in heat
2011 model check cooling and electrical components everything is working properly temp split 22,,,,recommend comfort plan