4127 E University Dr
Phoenix, AZ 85040
480-839-0082

Local Reviews
for fountain hills, az

Rated 5.0 out of 5 stars based on 2 customer reviews

mini-split install

  • Overall Experience
  • Quality
  • Price
  • Convenience

mini-split installation

Wes took the time to explain options & was the only one to correctly size the unit according to line size & construction.


Response from Ideal Air Conditioning and Insulation:

Thanks so much for the feedback, Phillip! So glad we could help!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for fountain hills, az

Nixa G.

Nixa G. Job Checkin

R- 410a Adjust Refrigerant level: Every pound after 1st RECOMMEND LEAK SEARCH BEFORE ADJUSTING REFRIGERANT CHARGE Purge gauges to ensure no non-condensables enter system Use digital scale to weigh in refrigerant Adjust according to units TP chart and super heat and sub cool

R- 410a Adjust Refrigerant level: Every pound after 1st
RECOMMEND LEAK SEARCH BEFORE ADJUSTING REFRIGERANT CHARGE
Purge gauges to ensure no non-condensables enter system
Use digital scale to weigh in refrigerant
Adjust according to units TP chart and super heat and sub cool

Charles B.

Charles B. Job Checkin

I found unit was pitched away from my drain. I re leveled air handler and verified good drainage.

I found unit was pitched away from my drain. I re leveled air handler and verified good drainage.

Chris M.

Chris M. Job Checkin

Air balance


Charles B.

Charles B. Job Checkin

Arrived to home Found short in 24V Blown control fuse Extensive rust throughout system Standing water inside AHU Primary pan no longer sloped toward drain Unit is level *Needs energy audit done **recommend replacement or additional repairs Repair

Arrived to home
Found short in 24V
Blown control fuse
Extensive rust throughout system
Standing water inside AHU
Primary pan no longer sloped toward drain
Unit is level

*Needs energy audit done
**recommend replacement or additional repairs

Repair

Eric  A.

Eric A. Job Checkin

- $2,000 IRA Federal Tax Credit System meets qualifications - Individual qualifications vary - May qualify for promotions, 0% for up to 60 months or low payment plans - Discount available for check payment *CLICK "VIEW MORE" on each line item to view included improvements

- $2,000 IRA Federal Tax Credit System meets qualifications - Individual qualifications vary

- May qualify for promotions, 0% for up to 60 months or low payment plans

- Discount available for check payment

*CLICK "VIEW MORE" on each line item to view included improvements

Chris M.

Chris M. Job Checkin

Service call


Cristian  Z.

Cristian Z. Job Checkin

AC installation in Fountain Hills

AC installation in Fountain Hills

Chris M.

Chris M. Job Checkin

No answer


Chris M.

Chris M. Job Checkin

Site visit for duct mod

Site visit for duct mod

Charles B.

Charles B. Job Checkin

Insulation installation in Fountain Hills. Air Barrier seal, Insulate to R38+, Insulate attic hatch


Charles B.

Charles B. Job Checkin

Arrived to home Spoke with Rob about issues Discussed current duct layout and detriment to system due to poor air flow Checked system Found bad condenser motor Found swelled capacitor Condenser fan motor Dual run cap - warranty


Charles B.

Charles B. Job Checkin

Arrived to home Found code 094 amongst others Shut off disconnect at CU and AHU breaker Waited 5 minutes and turned back on Found 65V between L1&L2 at disconnect Located breaker panel for CU Breaker showed the on position Shut off and turned back on Went to 205 then directly to 65 again Customer needs electrician to diagnose electrical issues Left disconnect off Need to return to start system once electrical is fixed


Nixa G.

Nixa G. Job Checkin

No cool call. Blower humming but not operational. Verified power to motor and board does not output high voltage to motor. Capacitor tested at 9.2 mfd out of 10mfd. Base repair needed is a new furnace control board. Also recommend a full inspection of the system to check all other components. System is down at time of departure. Customer will have home warranty repair.


Charles B.

Charles B. Job Checkin

Compressor Replacement R-410a under manufacturer's limited parts warranty Remove old compressor & filter drier while purging Nitrogen to prevent contamination Install new OEM compressor and filter drier Purge W/ Nitrogen while brazing to prevent contamination Pressure test entire system with Nitrogen to 500 PSI to ensure system is leak free Triple Evacuate system with digital micron gauge to below 250 Microns Re-charge system with new R-410a refrigerant to manufacturer's specifications Non Members: 90 day parts + labor warranty on all repairs Cool home members: 2 year parts + labor warranty on all repairs R- 410a Adjust Refrigerant level: Every pound after 1st RECOMMEND LEAK SEARCH BEFORE ADJUSTING REFRIGERANT CHARGE Purge gauges to ensure no non-condensables enter system Use digital scale to weigh in refrigerant Adjust according to units TP chart and super heat and sub cool


Matthew B.

Matthew B. Job Checkin

The unit had a loose outdoor fan motor and was rattling the system. I tightened the motor bolts. The unit was producing a poor temperature split and displaying a low charge. I found the true suction and true discharge service valves, failing and leaking Freon. The outdoor coil was dirty. I clean the outdoor coil and replace the service valves. I charge the system back to factory specifications.