Ryan H.

Ryan H. Job Checkin

Annual maintenance on a new Amana s variable speed heat pump and a Daikin mini split heat pump. Both systems are in fantastic shape and running as they should. Checked operation in both heat pump and the electric heat on the central system and checked the heating operation on the mini split. Treated the evaporator coil on the mini split to make sure the coil stays clean and changed the 16x30x1 air filter in the home. The systems are ready for the winter months ahead.


Caleb P.

Caleb P. Job Checkin

Completed the installation of all of the gas line, stubbed out for the stove and furnace in attic. Since there is no propane tank set yet, I recommend to wait to install the regulator until I can see what regulator he propane company is going to install on the tank. I would prefer them to do a first stage regulator and have everything underground high pressure and I will put a rego second stage on the stub up to the house. We will have to come back once tank is set to install regulator and finish the one connection to the house. Pressure is holding at this time.


Caleb P.

Caleb P. Job Checkin

Provided estimate for gas line.


Caleb P.

Caleb P. Job Checkin

17.2 SEER2 Variable Speed AC and Two Stage 80% Efficient Furnace with variable speed fan Moved unit to attic Ran high volt Ran low volt Ran new gas Ran new drain Sealed all air leaks Ran new return Vacuumed lineset Charged system Need dry wall guy to come out


Ryan H.

Ryan H. Job Checkin

Service call for a unit leaking water onto the floor technician arrived to the condensation drain line clogged up and the evaporator coil drain pan overflowed onto the floor. Cleared the drain line out and got it draining as it should here today. The system is back up and running as it should.


Chris V.

Chris V. Job Checkin

For this job, Technicians ran new high voltage wire for the mini split we installed within his garage. Technicians performed an A/C start up on the mini split. System works great at this time.


Ryan H.

Ryan H. Job Checkin

Maintenance call on a 2012 Goodman air conditioner. The system is in rough shape with the terminals on the capacitor melted and the wires leading to it. Also the contactor points are black and pitted. The compressor windings are deteriorating and it’s drawing to much power on start up. The service disconnect is melted to the point that it is unusable. The air handler is sucking water out of the evaporator drain pan and it is running over the blower motor and all of the indoor components. The system is running and cooling at this time but water is all over the floor surrounding the unit.


Caleb P.

Caleb P. Job Checkin

The technicians got called out due to a drain leaking. We arrived to find that the male connector coming out of the coil was leaking on the bottom. We cut it loose put a new one in and ensured it wasn’t leaking anymore. Everything is good to go now.


Ryan H.

Ryan H. Job Checkin

Service call for an air conditioner not keeping up. Technician found several holes in the duct work and the condenser is very dirty. Refrigerant levels are good here today. The blower motor was running in low speed during a call for air conditioning. Rewired the blower motor here today and will schedule a tune in the near further.


Caleb P.

Caleb P. Job Checkin

The technicians installed a new 17.2 SEER2 Variable Speed Heat Pump and High Efficiency Air Handler with Two Stage Strips as well as installed a new mini split for the garage. We made sure everything was level, and up to code. We also adjusted the refrigerant charge and air sealed everything with mastic. The new system is up and running great, the mini split needs the high voltage wire ran to be good to go. Whoever comes back out here next needs to bring some spray foam insulation to insulate the hole that was cut for the copper.


Caleb P.

Caleb P. Job Checkin

Technician arrived and performed a system diagnosis. System is a four year old Mr. cool mini split 2 ton. System was hit by a surge and fried the compressor surges are not covered by manufacturer warranty. Homeowner talked to Tim Holt on the phone and was given a quote of $5700 for replacement. Homeowner is going to reach out to his insurance to see about getting coverage.


Caleb P.

Caleb P. Job Checkin

The technicians installed a new coil and condenser. We made sure everything was level, air sealed with mastic and up to code as well as adjusted the refrigerant charge to ensure proper operation. Everything is set and ready to go for the summer time.


Chris V.

Chris V. Job Checkin

For this job, Customer states the system may be low on refrigerant that it is blowing hot air. Technician checked refrigerant levels and found the system is low on refrigerant, leaking within the indoor coil. The system is R-22 we can’t get that refrigerant. Customer is interested in replacing just a half system. Customer would like for Tim to come out later this afternoon to measure up and to get him preapproved for financing. There’s an install spot reserved for Ny on Monday afternoon.


Ryan H.

Ryan H. Job Checkin

Maintenance call on a 2007 Armstrong air system. The system is in great shape for its age. All capacitors and amp draws are within range. The refrigerant levels are good and the system is cooling as designed. The condenser coil was very dirty. The technician recommends regular cleaning to keep the system going as long as possible.


Ryan H.

Ryan H. Job Checkin

Service call for a heater blowing cold air. Technician arrived to find a bad sequencer not allowing voltage to the heat strips. Parts will be located in the morning and a solution for the customer.