View visual findings from this job here - https://visionshare.xoi.io/?id=XA-2F41-868D23158ECC4C80877399E28C455CF4 Return to preform leak diagnosis on Daikin heat pump system that is showing low pressure: * at arrival found NO path to the condensing unit and only a small corner of system is showing- completely buried in snow and ice * shovel out pathway to condensing unit and clear snow and ice from all ground condenser and condenser coil * connect gauges to system and confirm low pressure- the Schrader pain was found to be leaking at this time- removed and installed brand new * recover all refrigerant from system, removed leaking pin, and preform nitrogen pressure test on entire system at 500psi * removed slim duct cover to expose flare connections to indoor head * with system under pressure at 500psi- leak check all connections with bubbles- no bubbles or sign of leak / oil * the system held over 500psi for 30 minutes- ok * release all nitrogen from system and place the unit into a


Richard  .

Richard . Job Checkin

Today I arrived on site to address the issue with the HeatPump. Initial Assessment:Determined the HeatPump, a ductless system, was not working properly. Identified the fault as low pressure. Next Steps:Need to return with R32 refrigerant and the corresponding adapter to resolve the low-pressure issue. Upon arriving at the property, the client explained to me that the unit is operating endlessly. The customer believes that the indoor head has a fault. I proceeded to verify the system. This system is operating endlessly. The indoor head fan stops running momentarily. I proceeded to check the condenser unit. I found the system pressure low from R32. It is possible that this system has you some loss of R32. The unit is not displaying error codes at the moment but is operating intermittently. After charging the system and normalizing the pressures. It is necessary to contact technical support to diagnose the system due to the intermittent failure with the indoor head unit. -/-/-


Richard  .

Richard . Job Checkin

Today I arrived on site HeatPump System (R32) Fan Issue: Addressed an intermittent fan issue reported for the HeatPump system (R32). Air Filter Inspection: Discovered the air filters were heavily covered with dust. Maintenance Action: Washed the air filters to remove the accumulated dust. System Status: The HeatPump system is now operating normally. Upon arriving at the property, the client explained to me that the indoor heat occasionally stops running, minutes later it comes back and starts. I proceeded to verify the unit. I found the air filters covered with dust and kitchen grease. I proceeded to clean the air filters. I installed the filters in place, I told the customer that he should clean the filters frequently at least every 3 months. I proceeded to verify the outdoor unit. Stable pressures at this time. 410 psi heat mode Stable temperatures at this time. 125-130 F The client was left with the Heat operating correctly at this time. View visual findings from this job


Lorenzo M.

Lorenzo M. Job Checkin

Performed duct cleaning and sanitizing on 1st floor basement system. Remove and vacuum clean all floor registers to remove dust & debris before cleaning w/ duct cleaning machine. Disconnect all flexible duct Clean and polish all grilles. Clean return ductwork, Cut access opening in main plenum of supply and return ductwork to clean main supply trunk line and return. Secure all connections with patch plate, screws and silver tape. Ran system and sanitize after cleaning. System is back for normal operation @ this time. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-DE27-811B15AACB93490AB4D116D68DC47E5E Office to bill for service tomorrow @ the end of job