I recently had Innovative Air handle mechanical work at my home, and the service was excellent from start to finish. The team was professional, knowledgeable, and respectful of my property. They arrived on time, explained the work clearly, and completed the job efficiently without cutting corners. The quality of their workmanship was top-notch, and they went above and beyond to ensure everything was running perfectly before they left. It’s rare to find a company that combines technical expertise with great customer service, but Innovative Air delivered on both. I highly recommend Innovative Air to anyone looking for reliable and skilled mechanical work. They’ve earned my trust and future business.
Hight Efficiency gas boiler. X3) Gas Boiler. Perform a tune-up and cleaning to help ensure reliable and safe operation. Inspect for cracks & deterioration of Heat Exchanger. Check and clean Burners an heat exchanger- ok, vacuumed-ok Checked and cleaned flame sensor and ignition Assembly-ok Check Safety Controls-ok Check electrical wiring and components-ok Check Gas valve & Gas Line-ok Check Combustion Air & Exhaust, intake lines-okay Check GVD Damper-N/A Check Temperatures & Water pressure settings; Performance-ok Check and run Thermostats- operating well at this moment. Check circulation pumps-ok Check and clean condensate pump and drain line Check and run indirect hot water tank -ok Check for water leak,no leakage at this moment Check and clean condensation trap of the boiler-ok Check for water leak, no leakage at this moment. -note: NT1-P condensate pump needs to be replaced on the #2 right side boiler unit. water accumulator is leaking crack present. Run systems and left operat
Completed diagnostic on one comfortmaker gas fired furnace diagnosed the tube for the air pressure switch was clogged removed tube and cleaned highly recommend to perform a maintenance on the system system is nine years old homeowner stated he is waiting for a quote for the replacement of the system from innovative air solutions office personnel please follow up with the homeowner for the quote and to schedule a maintenance on the system left system working after checking for carbon monoxide and none was Detected View visual findings from this job here - https://visionshare.xoi.io/?id=XA-213F-21C3FC295FD7436E9F89F42505AA2F4A Maintenance Agreement
Preform maintenance on (1) Trane gas fired furnace: * shutters power to system at arrival * removed blower and furnace cabinet doors * removed all burner jets, flame sensor and hot surface igniter * cleaned flame sensor with copper bristle brush and polished clean * inspected hot surface igniter cleaned- ok * vacuumed and dusted out furnace cabinet and components * vacuumed and dusted / blew out blower cabinets and components clean and clear * vacuumed and brushed all burners clean * secured / inspected electrical wiring, connections, components, safety’s and zoning panel * inspected flue piping and inducer motor / assembly * reassembled furnace * brushed drain line and EZ trap clean and clear, flushed with fresh water and tested- operational no leaks * customer replaced his own filter every three months and still has time left on this filter * Vacuumed return box clean and clear * return power to system * call for heating from first floor thermostat: inducer motor on/ pressure and li
Helped Vern and Sergio on job site to run wire and put up slim duct
Today I arrived on site Visual Inspection:Performed a visual inspection for all equipment. This inspection covered the AC & Heating systems. Upon arriving at the property, the client Ma explained that she would like us to provide services to the AC and heating systems of this property. The client showed me the boiler room. In the boiler room there are 6x boiler units high efficiency hw boilers. The client also showed me 5x AHUs located in different places of the property. The client also has 5x condenser units (R410A) located on the right side of the property. 2x AHUs are located in the basement. 2x AHUs are located on the 2nd floor in the 2nd floor apartments. 1x AHUs located in the attic on the 3rd floor of the property. All systems have free access to do the services. The client also mentioned that she supplies the air filters of the AHUs. I checked all the systems. All systems are operating well at the moment. The client has a box kit in the boiler room with some piece
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A3D0-49A1AE50BDB84180BDBC327B97B3C65C
Installation of a new Unico High Velocity Air Conditioning System!