11 Kimball Place
Mount Vernon, NY 10550
914-793-7700

Local Reviews
for new rochelle, ny

Rated 4.8 out of 5 stars based on 22 customer reviews

Great service

Richard was very cooperative and answered all the questions clearly . The only issue was that in 3 days , they increased their initial invoice by $500 . However service done by Richard was good.

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Excellent service and appreciate the prompt response

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good customer Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Mark saves the day and this review!

Simply put, if it were not for Mark, this review would have a much more sour tone because of a past experience. However, let me be clear, not only was Mark thorough, professional and empathetic. He was very clear in what he was doing and WHY he was doing it. He resolved our issues and didn’t leave until we had heat and hot water. My family is very grateful! Thank you Mark! The ratings below are based on our collective experience with Innovative and does not reflect how pleased we were with Mark. He gets 5 stars across the board.


Response from Innovative Air:

Thank you Kindra. The technician prior to Mark has been removed from the company as a result of your experience. We set the bar high and do not settle for anything less. We appreciate your patience and the kind words about Mark. He is a fantastic technician. Thank you for allowing us to return and resolve the issue. We apologize for any inconvenience. Michael

  • Overall Experience
  • Quality
  • Price
  • Convenience

Reliable and Friendly

Lorenzo is a superb technician and a gentleman

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always excellent service

Always great service. Kind and courteous. The guys at innovative air have always helped us out and explained all for us to understand.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Lorenzo provided great service and was courteous and knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good job

I just posted on google but Nigel was on time ( early but okay with waiting for our scheduled time as we weren’t ready), polite and gentle with us and our dogs and did a very thorough job even draining the system which had air in it probably due to it not being done when you all installed the new one .

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent & Efficient Service

Lorenzo was very professional, thorough and efficient in conducting a heat maintenance tune up to my system.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Very polite and professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

I would recommend to anyone Innovative Air who has issues with there heating .

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for new rochelle, ny

Richard  .

Richard . Job Checkin

Completed heating maintenance on one hot water boiler, checked and cleaned the burners and understanding pilot assembly and replaced the thermocouple also clean burner tray and checked low water Cut off, also checked automatic water feed and expansion tank. The burners switch on side of boiler does not shut off the boiler but the circulating pump the emergency shut off switch located at top of basement. Stair does not work highly recommend to have Electrician visit site for installation of emergency shut off switch and service switch on boiler for safety concerns. Also perform maintenance on six Mitsubishi ductless Heat pumps checked and cleaned filters checked the blower wheels and sprayed evaporator coils. Also Performed maintenance on one ducted heat pump located in the attic checked electrical components and mechanical components. Check thermostat operations check systems operations also replaced two 12 x 12 by one Filter filters for the ducted system located in the attic checked a


Mark E.

Mark E. Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-DE27-62BCD4A3F8FC4A5CBE274E83B85C49D2 Customer has a leak from the ceiling under the furnace: * the system is off at arrival * open the ceiling access to the equipment * inspected the furnace * the furnace / overflow pan / and all components are 100% dry * the only water that was found was on the hatch for ceiling access under the humidifier * the humidifier was inspected * a screw was installed holding the humidifier water panel in place due to high static pressure * after reviewing humidifier install with customer he decided to shut the system down * close water feed valve to humidifier * shut down humidifier at thermostat and close bypass * turn thermostat back on as the heating side of equipment is operational with no leaks * recommend maintenance on furnace system


Mark E.

Mark E. Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-DE27-9852DB32796A4E7A9205687E072F6FC7 Perform maintenance on one Goodman, gas fired furnace: * Power down system at arrival * Open furnace and blower cabinet doors * Immediately noticed water dripping from the secondary heat exchanger on the furnace * Remove the flame sensor: Cleaned with copper bristle brush, and polished with steel wool * Remove the hot service igniter and inspected- okay condition * Secured Both components back in place * Vacuum and dusted out debris from furnace cabinet and components * Vacuum and dusted out debris from return box and blower cabinet and components * Replaced and dated 14 x 25 by one air filter * Clear, condensate drain line and trap and prime with freshwater * There is no neutralizer kit on this system, and this is a high efficiency furnace * Inspect Venting off of system- okay * Return power to equipment * Running and test heating: The furnace fires on his operating nor


Richard  .

Richard . Job Checkin

Today I arrived on site to address issues with the HVAC heating and AC system. **Inducer Motor:**Replaced the malfunctioning inducer motor. **Blower Wheel:**Performed a deep cleaning of the dirty blower wheel. When arriving at the client's property. I explained to the client about the work scheduled for this day. The client directed me to the basement where the unit is. I proceeded to disassemble the defective motor inductor. I proceeded to install the new inductor motor. I made all the connections and adjustments necessary to conclude the repair. I proceeded to disassemble the blower motor housing to do the deep cleaning. Take a part blower wheel and fan motor. I proceeded to clean and disinfect the interior cabinet of the unit. I proceeded to clean the blower wheel and the engine housing. I concluded with the deep cleaning of the unit. I installed the blower motor housing in its place. I started the system and monitoring for proper operation. The system did not fail or malfunction a


Lorenzo M.

Lorenzo M. Job Checkin

Upon arrival inspected boiler w/ customer. Discovered that customer has an oil boiler. Informed customer that unfortunately we do not service oil boilers and customer should get his oil company involved to service his system. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-DE27-CE4AA48B732F4AA3956B70916B8A04A9


Richard  .

Richard . Job Checkin

Hot Water Boiler. DHW water heater tank. Perform a tune-up and cleaning to help ensure reliable and safe operation. Inspect for cracks & deterioration of Heat Exchanger. Check and clean Burners, brush and vacuumed-ok Check and clean flame sensor and ignition Assembly-ok Check Safety Controls-ok Check electrical wiring and components-ok Check water feeder-ok Check back flow prevent-ok Check expansion tank-ok Check relive valve-ok Check Gas valve & Gas Line-ok Check Combustion Air, Flue pipe-ok Check Temperatures & Water pressure settings; Performance-ok Check and run Thermostats-okay Check circulation pumps-ok Perform inspection on a DHW tank. Check for water leak, no leakage at this moment. Check water valves-oKay Check ST-12 exp-N/A Check control gas valve-okay Check gas line- no leaks at this time Check Draft and combustion-okay Run and monitored for good operation-ok Run system, check hydro, all of them getting hot, left system operating well at this moment.. Perform maintenance


Mark E.

Mark E. Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-DE27-C296C31507B447F3A4E23DCCD52F831A Preform maintenance on x1 Carrier infinity gas fired furnace with bypass humidifier: * 6ft ladder needed to access system through x2 ceiling hatch’s * open furnace cabinet doors * shut power to system * removed flame sensor and hot surface igniter- cleaned sensor with copper bristle brush and polished clean with steel wool * inspected hot surface igniter- showing heavy ware and customer approved replacement * removed existing hot surface igniter and installed and secured brand new igniter and hardware in furnace * brushed out and cleaned burner jet, furnace cabinet and components * inspected PVC fresh air and exhaust: okay * secured all electrical wiring and connections in furnace and blower cabinet * inspected blower motor/ wheel and assembly * removed condensate trap- flushed clean and primed with fresh water * removed neutralizer kit- has never been cleaned / replaced-


Richard  .

Richard . Job Checkin

Today I arrived on site to address the no heat or hot water issue. Boiler Repair: Identified ignition faults on the boiler. Replaced the igniter assembly (provided by the customer). The boiler is now igniting after replacing the igniter assembly. System Status: Heating and DHW system is now operational. Upon arriving at the property, the client explained to me that the boiler is displaying a (error code). I proceeded to verify the unit. I found the unit displaying and error code (Ea) indicating ignition failures of the unit. I showed him and explained to the client the situation and about the failure that the system presents. Uncovering the unit, I found a bigger problem related to the unit's heater exchange. The heater exchange is leaking and is overheating the unit causing damage to the electrical components of the boiler. I showed the client and suggested she consider upgrading this system. I informed the client that I would pass all the necessary information to the office


Mark E.

Mark E. Job Checkin

Preform maintenance on x1 Carrier infinity gas fired furnace with bypass humidifier: * 6ft ladder needed to access system through x2 ceiling hatch’s * open furnace cabinet doors * shut power to system * removed flame sensor and hot surface igniter- cleaned sensor with copper bristle brush and polished clean with steel wool * inspected hot surface igniter- okay * brushed out and cleaned burner jet, furnace cabinet and components * inspected PVC fresh air and exhaust: okay * secured all electrical wiring and connections in furnace and blower cabinet * inspected blower motor/ wheel and assembly * removed condensate trap- flushed clean and primed with fresh water * removed neutralizer kit- has never been cleaned / replaced- customer approved * brought outside- dump minerals- washed and brushed clean- installed new minerals and put kit back together * reinstalled neutralizer kit, condensate trap and all drainage and tested for leaks- none * replaced air filter / open bypass damper * humidi


Mark E.

Mark E. Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-90AE-38BC50E705064C07828BC11F07228E5A Customer has no heat in the Entire home : * At arrival confirmed that the nest thermostat is calling for heating, but the furnace is not running * Check the furnace in the basement * This is a Lennox furnace that is about to be 27 years old * The vent louver door on the burner section is Trying to open with a call for Heat, but slamming shut * The motor for the damper is hot and you can see broken plastic that is holding the damper door * When the damper door is manually held down the furnace tries to fire, but fails * The wire For the electronic spark igniter is broken and not making connection * After manipulating the wire, the furnace does fire, but once hand is removed from the damper door, the furnace shuts down * This is a 27-year-old gas furnace. That is well over its average life expectancy with multiple issues. * No repairs are recommended on the system * Shut


Richard  .

Richard . Job Checkin

Perform heating maintenance on a Navien combi boiler. X1 Boiler unit. X3 AHUs Hydro air handler. Air Filters: X2) 14x24x1 X1) 14x30x1 Boiler: shop power to boiler Removed boiler covered doors- system, full of dust and debris Vacuum and dusted out boiler cabinet and components, under heat exchanger, burner tubes, and piping Removed pilot assembly, and spark igniter from boiler Clean spark igniter with copper bristle brush, and polished clean with steel wool Reinstalled and secured all connections Test expansion tank, water feed, and backflow preventer, air vent, and relief valve- okay Secured and inspected electrical wiring and components Inspect flue piping and damper motor- okay Polished and wiped down all equipment Return power to system Test take zoning panel, securing all connections- test Hydro and heating thermostat- zone panel response, circulator pumps on and running and boiler fires Monitor system operations, flames, boiler pressure and temperature- normal Boiler satisfies a


Richard  .

Richard . Job Checkin

Today I arrived on site to address issues with the 1st floor furnace. Initial Assessment: Confirmed the 1st floor heating & AC system was not working. Identified a loud noise originating from the unit. Diagnosis: Determined the inducer motor was not functioning correctly. Concluded the inducer motor needs replacement. Action Taken: Shut down the system due to the faulty inducer motor. Upon arriving at the property, the client explained to me that the unit on the 1st floor makes a noise when it starts at first then it stops making noises. I proceeded to check the unit, I found the furnace off. I told the customer to turn on the unit. The unit started. I immediately found the motor inductor locked, I tried to soften the inductor's impel. The unit started. Some time later it began to make noise. I showed it to the customer and explained that the engine inductor is not working properly. I also explained to the customer that it is possible that this piece is not on the market since due to


Richard  .

Richard . Job Checkin

Gas Furnace system. Perform a tune-up and cleaning to help ensure reliable and safe operation. Inspect for cracks & deterioration of Heat Exchanger. Check and clean Burners, brush and vacuumed-ok Check and clean Air Filter- replaced provided by the customer. 12x24x1 Check and clean ignition Assembly-ok Check and clean- flame sensor-ok Check Safety Controls-ok Check CO2-CO- okay Check electrical wiring and components-ok Check Gas valve & Gas Line-ok Check Combustion Air, intake & exhaust lines-ok Check Temperatures settings Performance-ok Check and clean condensate water traps-ok Check and cleaned Humidifier-N/A Check and run Thermostat- operating at this time. Inspected water heater Check for water leak-no leakage at this time. Check gas valve and gas Line-ok Ran water heater, operating well at this moment. Run system, left system operating well at this moment. Recommendations: x1 Duct cleaning. x1 Blower wheel deep cleaning. x1 heating & AC systems Membership. -/-/-/-/-/-/- - R


Mark E.

Mark E. Job Checkin

Customer has no heat in home: * at arrival confirm that thermostat is calling for heating indoor temp 61 and set for 74 * check boiler in basement * confirm that the circulator pump is not running and the pilot light is out on the boiler * After further diagnostic found that the boiler was not receiving a call from the thermostat * When the thermostat was bypassed and jumped out, the vent damper opens, and the circulator pump turns on, but the boiler remains off due to the pilot light being out * Also, while visually inspecting the boiler, noticed that the expansion tank seemed full of water- We brought it to the customers attention that after the thermostat and the thermocouple replacement it is possible that the boiler may leak water onto the floor and expansion tank replacement is needed * She approved the thermostat and the thermocouple replacement on her system * Removed existing thermocouple from boiler And disconnected from gas valve and pilot assembly * Perform full maintenanc


Lorenzo M.

Lorenzo M. Job Checkin

Heating Maintenance on 34yr old Trane Gas Furnace system. Perform a tune-up and cleaning to help ensure reliable and safe operation. Inspect for cracks & deterioration of Heat Exchanger Check and clean Burners, brush and vacuumed-ok Check and clean Air Filter- replaced. x1) 16x25x1 provided by customer Check and clean ignition Assembly-ok Check and clean- flame sensor/Flame rod-ok Check and tested hot surface igniter Check Safety Controls-ok Check CO2-CO- okay Check electrical wiring and components-ok Check Gas valve & Gas Line-ok Check Combustion Air, intake & exhaust lines-ok Check Temperatures split Performance-ok Check and clean condensate water traps-ok Check Humidifier-N/A Old Fashioned. Customer plug in when ready to use Hum water panel- N/A Check and run Thermostats- operating at this time. Inspected water heater Check for water leak- no leakage at this time. Check gas valve and gas Line-ok Ran water heater, operating well at this moment. Ran system, left system operating well