I would recommend Jackson n son's to everyone they are courteous and professional
For nearly two weeks, I lived without heat. Finally, I got heat today… I called, Jackson & Sons & Jerry, was able to successfully help me. I expressed; the horrible way I was treated by a warranty company and that I was so cold. I cannot brag enough about Nate from Jackson & Sons. I received top of the line service and he explained to me, the issue that he found with my system, along with; awesome pricing. This company is in high demand and I can clearly see why.
The Service technicians were knowledgeable & thorough. We appreciate the friendly and great service we received.
Amazing customer service! Our tech Brandon was polite and extremely knowledgeable. Highly recommend.
The service technician, Noah, was very professional. He explained the service he was to perform and then, reviewed his report with us.
Came unprepared to complete service. Requires another service call with a charge to charge AC unit
technician was very courteous, informative and efficient. performed his service call well and kept us informed of what he saw and noted.
Performed CMA inspection. System cooling properly as of now.
Performed CMA inspection. Amp draws within range, all systems turned on and operated without challenges.
Tech accessed unit on the roof and found no power to the unit or the disconnect. Tech tested the compressor, blower motor and condenser fan motor. Found no challenge with unit, located breaker panel and found 50 amp breaker labeled entrance A/C in the off position. Tech cut breaker on, went back on roof and verified power at disconnect. Restored power to unit and unit was working at time of departure. Suspect breaker was cut off by mistake.
Call arrival. Tech found no thermostat on wall. Upon further inspection. Check found thermostat wire in ceiling. No thermostat. Tech added power to unit tech jump blower to engage blower. Is the belt driven motor. Evaporator coil is rusty. Tech jump condenser. Upon further inspection on condenser tech found outdoor fan motor is seized. 1/2 HP 1075 RPM. Unit will need condenser motor to further inspect spoke with susi she would like quote on replacing and repair
Tech found ah was operating but not cooling tech found the condenser motor was not operating or compressor unit was receiving 24vs and had 210 volts but compressor was not operating tech checked pressure standing pressure is 139/138 enough to engage tech believes since outdoor fan not operating made compressor go into thermal overload 1/3hp 1075rpm motor would need to be replaced to further diagnose unit
AH 1 S#6359 tech found the unit has p trap would recommend replacing with ez trap tech did see mold in the blower unit will require maintenance blower amps and capacitor is within specs upon further inspection of condenser unit s#1448 tech found compressor sounding bad as it is ready to fail and unit slightly low on refrigerant 43/153 for a r22 system tech recommend leak search tech recommends looking at unit replacing due to age and type of refrigerant. AH2s#3324 tech found rust on coil as well as a p trap connection to the aux pan drain connection both going to a 1in pipe drain. Tech did find mold in blower Amos and capacitor readings are within specs. Tech did see cabinet of unit having dried up mold upon further inspection tech found condenser s#5560was extremely low on refrigerant indication of a major leak 28/133for. R22 system tech recommend S replacement due to age and type of refrigerant
FOUND SYSTEM LOW ON CHARGE OUT ON HARD LOCKOUT. PERFORMED LEAK SEARCH. ONLY ABLE TO FIND SMALL LEAK AT TXV BOLTING. TIGHTENED DOWN AND ADDED 1.5LBS OF R410A. WARRANTY.
Tech found no difficulties at this time. Homeowner said he will call in next and renew plan.
Performed maintenance service on electric furnace and split ac.
Tech preformed esa first maintenance per energy savings agreement found no challenges at todays visit system is operating correctly at this time. Tech replaced 2 16x20x1 filters.
Customer invest in ESA 1 system twice a year Customer would like to rotate visits for each system very maintenance Tech also installed focus pro 5000 tstat after customer approval
Tech preformed CMA FULL SERVICE on 3 split systems. All systems are operating at this time. System 1 shows signs of electrical failure starting on the blower motor. Tech has attached estimate for replacement to invoice. System 3 has a weak blower capacitor and tech has attached estimate for replacement to invoice. Tech also has attached system performance reports to invoice.
Tech found unit was not receiving power tech cycled breaker on and off unit did get power tech called for cool fan only would turn on tech then checked pressure and found compressor at 1psi tech did educate customer on process of leak search and leak repair if possible unless coils the part ordered if needed then refrigerant recharge customer wants quote on new unit as well