2330 Indian Springs Rd
Dudley, NC 28333
(919) 734-9611

Our Top Cities


Local Reviews
for newton grove, nc

Rated 4.9 out of 5 stars based on 32 customer reviews

Great service.

Very professional.

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Excellent service

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

As always great job

They take good care of my hvac

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Great service

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Great service

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

New ac we love it

You just can’t find a better company in this area there here when you need them all the guy that take care of the ac unit and service

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Annual serviced

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Great service

Great job as always


Response from Jackson & Sons:

Thanks for leaving us such a wonderful review. We are glad that you loved our services, our dedicated staff will be pleased to learn of your high praise.

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

EXCELLENT SERVICE!

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

great service

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Great service!

Jackson & Sons was great to work with; most expedient, on time and thorough in their delivery.

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Very professional

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Did a good job

It was just fine

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Great Service

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Super good company. Service is great

Great service and great technician. Give him a raise. My unit is fixed running like a gem. Glad we bought from you all. Service best anyone could ask for.

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Job Locations
for newton grove, nc

Jesse J.

Jesse J. Job Checkin

Tech preformed CMA FULL SERVICE on 8 Split Systems. Split System #4 was still down from previous visit in February. Maintenance told tech that First Response had come out and stated that fire system was not reason why system was down. Tech went to verify First Response findings. Tech verified that low voltage to system was being interrupted. Tech isolated fire system from air handler for test purposes only. System then began to operate with all components connected excluding fire system. When tech reconnected fire system, the Air Handler shut down. All signs lead tech to the conclusion that fire system is interrupting low voltage. Executive Director had First Response come out to investigate. First Response corrected issue and System is operating at this time. Tech did find the contactor coil is getting hot and cause contactor to intermittently operate. Tech recommends replacing contactor and has attached estimate to invoice. Split System #6 does operate at this time but tech recommend


Jesse J.

Jesse J. Job Checkin

Tech preformed CMA FULL SERVICE on 20 Split Systems. Split System 3C is operating at this time but during inspection tech found a weak Run Capacitor and the compressor failed megohm test. Due to these challenges and age of system tech recommends replacing system over repair. Office will contact customer with further solutions. Tech found Compressors in both Split Systems 2E and 4E had tested in the caution area of megohm test and the Run Capacitors also tested weak. Tech recommends replacing Run Capacitors and installing Hard Start Kits to prolong life of Compressors. Tech has attached estimates to invoice. Tech also found that Compressors in Split Systems : 2A, 4B, and 4C had tested in caution area. Tech recommends installing Hard Start Kit to prolong life of Compressors. Tech has attached estimates to invoice. Split Systems 1C, 2C, and 2D tested with weak Run Capacitors and Tech recommends replacing Run Capacitors. Estimates for Run Capacitor replacement are attached to invoice. Spli


Spencer C.

Spencer C. Job Checkin

Tech found the purple common wire was off of the DC relay. White was getting 28v. Tech connected the wire and found heat strips operating properly. Tech also tested regular heat and found normal operation. Supply temp 104 and climbing.


Spencer C.

Spencer C. Job Checkin

Tech found coil completely frozen on circuit 2. Circuit 1 has been down since September. Tech thawed coil and leak searched system. No leaks present. Tech found normal head pressure at 320 with 80 degree outdoor temp, low suction and high superheat. This indicates a restriction. Tech found orifices freezing directly after metering device and tech recommends replacing coil. Tech also found a cracked belt and recommends replacing it as well. Tech recommended looking at comparing repair price to unit price. Field supervisor notified


Matthew L.

Matthew L. Job Checkin

Customer reports system freezing up. Tech found electric furnace and outdoor unit very dirty. System has low suction pressure and high superheat. Tech estimated system is 1-2 lbs low on R410a. Initial leak search did not show any obvious refrigerant leaks. Customer says Lowe’s has added refrigerant about 6 years ago. Tech recommended cleaning system and adding refrigerant. Tech also found 7.5 blower capacitor weak and dual run capacitor weak. Customer approved MPA, first tune up, Housecall, and 2 lbs of R410a. Tech thoroughly cleaned system. Started system up and found blower motor failed to start and overheated due to weak capacitor. Tech replaced capacitor for testing and found it started and ran normally. Customer approved capacitor replacement. Let customer know that we can provide a free quote at any time for system replacement. System is 10 years old. If they need to put money towards a major repair, tech recommends replacing system. Financing options are available. After clea


Joseph C.

Joseph C. Job Checkin

Tech performed ESA on 1 system found no challenges at today’s visit, tech inspected ducts very thoroughly customer stated mice were coming in through them. Tech found no challenges with ducts but did notice termite damage tech informed customer of findings no further challenges today. Crawl space is very tight


Joseph C.

Joseph C. Job Checkin

Tech performed ESA on 1 system found no challenges at today’s visit system operating properly at this time. Customer Extended ESA


Matthew L.

Matthew L. Job Checkin

Customer wanted ballpark over the phone. Said it was out of her price range.


Noah C.

Noah C. Job Checkin

Upon arrival customer stated system was charged up with refrigerant last month by a different company. Stated blower runs continuously and indoor temp got to 85 on a recent warm day. Tech found system out on low pressure and system almost completely out of refrigerant. Recommended performing a leak search, tech performed leak search after approval. Search resulted in finding of a leak at evaporator coil. Quoted $5730 to replace coil, system is out of warranty. Customer would like a quote on a new system. Field supervisor is scheduled to come out.


Derek J.

Derek J. Job Checkin

Upon arrival tech was informed system was not cooling. Upon inspection of the system tech found evaporator coil starting to freeze system. Factory subcooling called for 15 degresss and was only at 2 degrees subcooling. Tech leak searched system and found factory u bends on evaporator coil to be leaking. Tech added 6lbs of R410A to system to get them back cooling. Office is ordering warranty evaporator coil to replace.


Ricardo  T.

Ricardo T. Job Checkin

Text washed and serviced unit and found no challenges at this time. Customer would like to renew but was unable at this time customer should call office for renewal.


Ricardo  T.

Ricardo T. Job Checkin

Visa - 4334770052138614 (cvv)(963) exp(03/29) zip (28366) card info.


Ricardo  T.

Ricardo T. Job Checkin

Tech Performed maintenance per esa. Tech found no challenges at today’s visit system is operating correctly at this time homeowner did not let tech inside dropped off filters not check delta t. Homeowner will let me know what he will do with renewal he might drop the plan on one of the properties but he will let us know before today.


Noah C.

Noah C. Job Checkin

Tech performed CMA on one system. Tech found compressor contactor to be dark and pitted. Recommended replacing. Also recommend replacing weak compressor run capacitor. Estimate is on file for these repairs and sent to customer. Tech found no further challenges with system, system is heating and cooling properly at this time.


Joshua W.

Joshua W. Job Checkin

Tech arrived and found thermostat set to 65, tech checked system and found insulation on coil door had come loose and was restricting air flow, tech taped insulation back to door and verified proper operation of unit, tech also had to recalibrate and set temperature on thermostat due to temperature ding 2.5 degrees off. System is now on and operating with proper delta t.