Matthew L.

Matthew L. Job Checkin

Emailed proposal, customer is getting multiple quotes.


Bryce C.

Bryce C. Job Checkin

Wife not home, has to talk to wife


Luis R.

Luis R. Job Checkin

Te h found distribution tubes were freezing up with mins of operation.t3ch found evaporator coil extremely rusty tech performed leak search and found leak inside evaporator coil. Tech inspected od system and found no leaks and compressor meged in green. System is from 2010 tech called for field supervisor to go give best solution for customer scheduled to come out at later today.


Matt C.

Matt C. Job Checkin

Tech washed and serviced unit


Kyle W.

Kyle W. Job Checkin

STATED UPSTAIRS SYSTEM CONDENSER FAN STOPPED RUNNING THIS MORNING AND WATER CAME FROM BOTTOM OF CONDENSER. THIS IS NORMAL DEFROST OPERATION FOR HEAT PUMP SYSTEMS. SPOKE WITH MRS. COX. NO CHALLENGES FOUND AT THIS TIME.


Spencer C.

Spencer C. Job Checkin

Tech smelled a large leak by the rheem gas pack regulator and performed a leak search. Tech dug up by the line and found a large leak in the gas line. Tech shut the tank off and found the tank almost empty. Customer is calling the gas company.


Spencer C.

Spencer C. Job Checkin

Tech replaced blower motor and found blower running properly. Tech also tested refrigerant pressures and temperatures to be sure suction pressure and superheat are good with the new blower. System is running properly at this time. Collected a check for 456.39


Noah C.

Noah C. Job Checkin

Upon arrival tech found failed blower motor and module at air handler for Rheem split system. Tech quoted $459.36 for repairs. Will need to order new module and motor under warranty. Call customer and schedule repair when motor arrives. Collected $87.00 plus tax per Housecall fee.


Luis R.

Luis R. Job Checkin

Tech found compressor had a grinding noise upon start up and shut own tech also found condenser coil has a leak as well tech spoke with ms Cynthia and let her know of leak found and compressor noise she wants quote on repair and replacing


Matthew L.

Matthew L. Job Checkin

Tech found system not cooling due to a failed 35/5uf dual run capacitor. Trane comfort site reports functional parts good until 2031. Customer approved replacing. System is back cooling. No housecall per premium agreement.


Kenny C.

Kenny C. Job Checkin

Upon arrival tech found dead dual run capacitor. Tech replaced capacitor with turbo capacitor, system up and cooling. Recommended ESA.


Luis R.

Luis R. Job Checkin

Upon arrival customer informed tech that when they turned on ac within a few hours they saw that water mark upon further inspection. Tech did not find any drain issues with the unit no drain lines above the ceiling where the water Mark is except aux drain which drain pan is dry indicating no water in the aux drain line present tech did find a vent pipe going through roof near the area when tech moved insulation around tech found some insulation moist but not wet customer invested on mpa tech did not find any issue with unit