This is a five-star company, and now I know why. Charlie quickly diagnosed our AC problem, fixed it without pressure to replace an aging system, and cleaned out the AC with a hose. So happy!
Response from LaSalle Heating and Air Conditioning Inc:
We appreciate the feedback Sam. Thank you!
They did what was needed to get my AC up and running
Response from LaSalle Heating and Air Conditioning Inc:
Thank you Tim.
Response from LaSalle Heating and Air Conditioning Inc:
Holly, we are always happy to help. Give us a call in the future if you ever need out services.
Response from LaSalle Heating and Air Conditioning Inc:
Thank you for the 5 star review.
Charlie did a great job, pleasant fellow, I'll be using you again.
Response from LaSalle Heating and Air Conditioning Inc:
Thank you Greg! We appreciate your business and I will be sure to tell Charlie the positive feedback.
Response from LaSalle Heating and Air Conditioning Inc:
Thank you Mike. Call us anytime.
Max went above and beyond and explained a lot about our furnace. He showed me how to take care of my AC. He talked about duct cleaning and he explained my air exchange system. He took the time to make us aware. Amazing top notch person. I’d request him in person if I could. Fabulous and informative. Thanks Max
Response from LaSalle Heating and Air Conditioning Inc:
Always happy to help and share our knowledge. Give us a shout if you have any questions or need our services in the future.
Very helpful for knowing future options.
Response from LaSalle Heating and Air Conditioning Inc:
We are always happy to help Josh! Looking forward to our future endeavors.
Was very knowledgeable, nice, and kind
Response from LaSalle Heating and Air Conditioning Inc:
Thank you Bobby. I am glad we were able to help!
Qualifies for Bryant promotional financing, 5 years interest free. If not paying with cash or check, LaSalle will remove cash discount from invoice. Free 4†filter system with complete installation. Free Connex Control with evolution system installed
Found fan motor and compressor not running when I arrived. Found capacitor to be bad. Replaced capacitor and all components turned on and were functioning. Cleaned condenser coil. Checked refrigerant levels, refrigerant checked donut good. Compressor is getting weak in unit. No data left on unit but a/c is at least 25 years old. Recommend replacing a/c system soon.
Found Air Conditioner not functioning -Air Conditioner Was failing due to high pressure switch Found condenser fan motor not running Found Condenser coil extremely dirty Found Dual Run capcitor bad -cleaned condenser coil with chemical cleaner -replaced dual run capacitor checked refrigerant charge
Found condenser fan motor miswired Rewired condenser fan motor Checked refrigerant
Found fan motor to not be running when I arrived. Found capacitor to be bad. Replaced capacitor and fan turned on and was functioning. Found condenser coil to be very restricted causing poor airflow through condenser. Cleaned condenser coil. Found air filter very restricted. Customer was unaware about changing the air filter. Removed air filter to test system. Checked refrigerant levels and refrigerant checked out good. Recommend keeping air filter and condensing unit clean.
Found condenser fan motor not working Replaced condenser fan motor and dual run capacitor
Found high pressure switch to be tripped. Reset switch and fan motor did not start. Found capacitor to be bad. Replaced capacitor and compressor and fan turned on. Checked refrigerant levels, refrigerant looked good. Found kink in suction line entering house causing poor circulation of refrigerant. Recommend fixing kink when a/c gets replaced.
Found system low on refrigerant. Recharged system with 1.5 lbs refrigerant.
Found condenser coil dirty - cleaned coil Found unit low on 410A refrigerant - charged system
Performed A/C membership visit. Found condenser coil to be very restricted causing poor airflow through condenser. Cleaned condenser coil. Ran unit to dry coil out. Checked electrical components, capacitor is rusty but tested out good. Checked air temp entering vs leaving condenser to ensure good airflow after cleaning coil. Checked refrigerant levels, refrigerant checked out good. Unit was working well. Recommend keeping air filter and condensing unit coil clean.
Found mouse had chewed through 2 wires Spliced both wires recommend replacing compressor wiring harness
Found Air conditioner not running Checked for power Found no power at outside unit disconnect Found circuit breaker tripped Reset circuit breaker Found unit drawing higher than normal current Condensing unit was extremely dirty Cleaned condensing unit and checked current draw Air conditioner was drawing approximately 8 Amps after coil cleaning Recommend keeping coil clean to ensure proper operation and keeping air conditioner running as efficiently as possible Checked refrigerant levels
Found system low on refrigerant -charged system -added stop leak product into system with us dye
Performed a/c membership visit. Found a/c to be working when I arrived. Found condenser coil to be very restricted causing poor airflow through condenser. Pulled hail guards and clean coil with water and chemicals. Ran unit and found everything to be working well. Checked electrical components, checked refrigerant levels, checked air temp entering vs leaving condenser. Everything checked out good. Recommend keeping air filter and condenser coil clean.
Found mouse nest in air conditioner Cleared mouse nest Found unit 3 pounds low on r22 refrigerant Charged system System has a leak and there is no guarantee on how long refrigerant will last System is in rough shape Customer should plan on replacing system