Went for a service call today. Customer mentioned the house wasn’t cooling well. When checking pressures, I noticed the super heat was really high and the suction side was low. After doing a few tests, I figured out that the piston is clogged, going to replace filter dryer as well. Thank you for choosing LBA services!