TOP NOTCH SERVICE. Installed whole house humidifier on our existing furnace. Techs arrived on time and were professional & friendly. Installation was FIRST CLASS start to finish. Competitive price. Definitely recommend.
I completed diagnostics and found the condenser fan motor failed. I explained repair / replacement options with customer. The customer opted to replace the condenser fan motor. I replaced motor and capacitor. The system is now operational. I found R22 pressures low which indicates there is a leak in the system. The customer gave me permission to add the R22 until proper pressures. The system is cooling on departure.
I completed diagnostics and found the condenser fan motor failed. I explained repair replace options with customer. The customer opted to replace the condenser fan motor. I replaced motor and capacitor and the system now operational. I found R22 pressures low which indicates there is a leak in the system. The customer gave me permission to add the R22 until proper pressures. The system is cooling on departure.
I completed Scheduled Maintenance Agreement Update for Customer that came with recent Installation of Carrier 16 SEER 3.5 Ton Air Conditioner.
I installed a Five Star 80% 45,000 BTU Gas Furnace 3T 14", and a Five Star 13 SEER 2 Ton Air Conditioner. These new systems replaced the existing TRANE gas furnace and air conditioner.
I installed a Carrier 96% 60,000 BTU Gas Furnace and a Carrier 13 SEER 2.5 Ton Air Conditioner.
I found a the whole burner area was burned black due to improper combustion. I performed a combustion analysis and found over 4,000 ppm of CO in the flue. I told customer furnace needed to remain shut off until this system was repaired or replaced. Customer decided to replace furnace.
I provided an estimate for a new Carrier 96% Variable-Speed Two-Stage Gas Furnace and a new Carrier 16 SEER Air Conditioner
I Performing our Five Star Tune-Up & Safety Check on a Trane Air Conditioner
Performing our Five Star Tune-Up & Safety Check on a 2013 Trane Air Conditioner
Duct cleaning and Lennox furnace tuneup. All is working properly at this time.
Payne furnace exhaust motor struggling to start up and over heating. Capacitor reading found to be low and motor bearings starting to squeak and hum. Options given to replace the motor or furnace.
Payne furnace exhaust motor struggling to start up and over heating. Capacitor reading found to be low and motor bearings starting to squeak and hum. Options given to replace the motor or furnace.
Payne furnace exhaust motor struggling to start up and over heating. Capacitor reading found to be low and motor bearings starting to squeak and hum. Options given to replace the motor or furnace.
Payne furnace exhaust motor struggling to start up and over heating. Capacitor reading found to be low and motor bearings starting to squeak and hum. Options given to replace the motor or furnace.
Free quote provided to install a Carrier Gas Furnace and A/C in place of a Goodman Furnace and Rheem Air Conditioner.