Aprilair humidifier

enjoying our new humidifier, price was a steal!

  • Overall Experience
  • Quality
  • Price
  • Convenience

FIRST CLASS

TOP NOTCH SERVICE. Installed whole house humidifier on our existing furnace. Techs arrived on time and were professional & friendly. Installation was FIRST CLASS start to finish. Competitive price. Definitely recommend.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for galena, oh

Jacob M.

Jacob M. Job Checkin

I completed diagnostics and found the condenser fan motor failed. I explained repair / replacement options with customer. The customer opted to replace the condenser fan motor. I replaced motor and capacitor. The system is now operational. I found R22 pressures low which indicates there is a leak in the system. The customer gave me permission to add the R22 until proper pressures. The system is cooling on departure.


Jacob M.

Jacob M. Job Checkin

I completed diagnostics and found the condenser fan motor failed. I explained repair replace options with customer. The customer opted to replace the condenser fan motor. I replaced motor and capacitor and the system now operational. I found R22 pressures low which indicates there is a leak in the system. The customer gave me permission to add the R22 until proper pressures. The system is cooling on departure.


Stephanie G.

Stephanie G. Job Checkin

I completed Scheduled Maintenance Agreement Update for Customer that came with recent Installation of Carrier 16 SEER 3.5 Ton Air Conditioner.

I completed Scheduled Maintenance Agreement Update for Customer that came with recent Installation of Carrier 16 SEER 3.5 Ton Air Conditioner.

Robby D.

Robby D. Job Checkin

I installed a Five Star 80% 45,000 BTU Gas Furnace 3T 14", and a Five Star 13 SEER 2 Ton Air Conditioner. These new systems replaced the existing TRANE gas furnace and air conditioner.

I installed a Five Star 80% 45,000 BTU Gas Furnace 3T 14", and a Five Star 13 SEER 2 Ton Air Conditioner.  These new systems replaced the existing TRANE gas furnace and air conditioner.

Robby D.

Robby D. Job Checkin

I installed a Carrier 96% 60,000 BTU Gas Furnace and a Carrier 13 SEER 2.5 Ton Air Conditioner.

I installed a Carrier 96% 60,000 BTU Gas Furnace and a Carrier 13 SEER 2.5 Ton Air Conditioner.

Jacob M.

Jacob M. Job Checkin

I found a the whole burner area was burned black due to improper combustion. I performed a combustion analysis and found over 4,000 ppm of CO in the flue. I told customer furnace needed to remain shut off until this system was repaired or replaced. Customer decided to replace furnace.

I found a the whole burner area was burned black due to improper combustion. I performed a combustion analysis and found over 4,000 ppm of CO in the flue. I told customer furnace needed to remain shut off until this system was repaired or replaced. Customer decided to replace furnace.

Jacob M.

Jacob M. Job Checkin

I provided an estimate for a new Carrier 96% Variable-Speed Two-Stage Gas Furnace and a new Carrier 16 SEER Air Conditioner

I provided an estimate for a new Carrier 96% Variable-Speed Two-Stage Gas Furnace and a new Carrier 16 SEER Air Conditioner

Lee E.

Lee E. Job Checkin

I Performing our Five Star Tune-Up & Safety Check on a Trane Air Conditioner

I Performing our Five Star Tune-Up & Safety Check on a Trane Air Conditioner

Lee E.

Lee E. Job Checkin

Performing our Five Star Tune-Up & Safety Check on a 2013 Trane Air Conditioner


Lee E.

Lee E. Job Checkin

Duct cleaning and Lennox furnace tuneup. All is working properly at this time.

Duct cleaning and Lennox furnace tuneup. All is working properly at this time.

Haidar H.

Haidar H. Job Checkin

Payne furnace exhaust motor struggling to start up and over heating. Capacitor reading found to be low and motor bearings starting to squeak and hum. Options given to replace the motor or furnace.

Payne furnace exhaust motor struggling to start up and over heating. Capacitor reading found to be low and motor bearings starting to squeak and hum. Options given to replace the motor or furnace.

Haidar H.

Haidar H. Job Checkin

Payne furnace exhaust motor struggling to start up and over heating. Capacitor reading found to be low and motor bearings starting to squeak and hum. Options given to replace the motor or furnace.

Payne furnace exhaust motor struggling to start up and over heating. Capacitor reading found to be low and motor bearings starting to squeak and hum. Options given to replace the motor or furnace.

Haidar H.

Haidar H. Job Checkin

Payne furnace exhaust motor struggling to start up and over heating. Capacitor reading found to be low and motor bearings starting to squeak and hum. Options given to replace the motor or furnace.

Payne furnace exhaust motor struggling to start up and over heating. Capacitor reading found to be low and motor bearings starting to squeak and hum. Options given to replace the motor or furnace.

Haidar H.

Haidar H. Job Checkin

Payne furnace exhaust motor struggling to start up and over heating. Capacitor reading found to be low and motor bearings starting to squeak and hum. Options given to replace the motor or furnace.

Payne furnace exhaust motor struggling to start up and over heating. Capacitor reading found to be low and motor bearings starting to squeak and hum. Options given to replace the motor or furnace.

Haidar H.

Haidar H. Job Checkin

Free quote provided to install a Carrier Gas Furnace and A/C in place of a Goodman Furnace and Rheem Air Conditioner.

Free quote provided to install a Carrier Gas Furnace and A/C in place of a Goodman Furnace and Rheem Air Conditioner.