I completed a Full Install of a Carrier Electric Furnace FX4D (Up to 100,000 BTU) Honeywell T10 Programmable Thermostat Carrier 14 SEER Heat Pump 25HCE4 (Up to 3 ton) The system is operational upon departure.
I completed diagnostics and spoke to the customer and she stated tstat will not shut ac off once it reaches set point. I found that the contactor is not sticking. I found pressures that indicate the system is over charged. I explained to customers mom who sounded very confused about what’s going on. I explained there is nothing happing at this moment so issue must be intermittent. I offered to replaced tstat for $99 plus call fee and the customer approved. The system is operational in heating and cooling at departure.
I installed a Five Star 80% 45,000 BTU Gas Furnace 3T 17" and a Five Star 13 SEER 2.5 Ton Air Conditioner. These new systems replaced a Lennox gas furnace and air conditioner. Both new systems were fully operational upon departure.
I gave an estimate to install a new Five Star Multi-Speed 2.5 Ton Electric Furnace / "Slant" Coil and a new Carrier 14 SEER 2.5 Ton Heat Pump.
I installed a Five Star 15 SEER 2.5 Ton Heat Pump, a Five Star Multi-Speed 2.5 Ton Electric Furnace / Fan, and an iWave-R Air Purifier.
I installed a Carrier 80% 70,000 BTU Gas Furnace and a Carrier 16 SEER 2.5 Ton Air Conditioner. I cycled the system to ensure everything was in working condition. System is operational upon departure.
I found the wiring to be loose and secured it. I also notice the high limit switch was having some issues. I informed the customer we may need to replace it in the future and quoted him a price so he would know for the future. System is operational upon departure.
I installed a Carrier 96% 60,000 BTU Gas Furnace and a Carrier 16 SEER 3 Ton Heat Pump with a propane conversion kit. Everything working properly at time of departure.
I installed a Carrier 96% 60,000 BTU Gas Furnace and a Carrier 16 SEER 3 Ton Heat Pump
I found the inducer motor had completely failed. I presented the repair and replace options to the customer and they decided to replace the system. Unit not operational on departure per inducer motor failing.
I arrived to do a Real Estate Inspection on their heating and air conditions systems. This is a preventative maintenance and it catches minor problems before they become very large problems.
I am Performing our Five Star Tune-Up & Safety Check on a 1999 Trane Gas Furnace. All readings were within manufacturer's specifications, unit operating properly at this time.
I Replaced the OEM Evaporator Coil on the 2014 Trane
I added 2 pounds of Refrigerant R-22 Freon into a 1995 Trane
Replaced Nest thermostat on Carrier system. All is working properly at this time.