Awesome as always..Jack is a real asset to your company.
Response from Moon Air Inc.:
We are so grateful for your 5-star review.
I scheduled an estimate visit with Steve Podesta after meeting him at the Middletown Peach Festival, where I asked him about the mini-split. The visit took place on 6 Sept, 2023 and was great. Steve analyzed the room where I'd place the mini-split, shared some options about its possible placement in the room and outside, carefully explaining how the coolent and drainage pipes would be placed/arranged coming from the room to the outside pump. He worked up a proposal with my options and provided the product literature for the units proposed. I have all I need to make a decision. I'm very satisfied with the visit. Thanks!
Jack, was very professional and did a fantastic service job!
Kyle was very knowledgable and professional. He walked me through everything he did and offered advice for future projects I have. I would certainly use Moon Air again and would request Kyle in the future.
Guy came out last Thursday around 2 and haven’t heard back. Others gave me quotes right then or within a day. W
Club service gas warm air, changed customer supplied air filter, test ran in heat, inducer fan amps 2.6, glow bar .6, indoor fan 3.7, flame current 2.1uamps, operation normal at this point.
Club service gas warm air two systems, 2nd floor system, non repeatable coolant leaks on indoor Coil, heat exchange system very rusty, test ran, operation normal at this point. Basement and first floor system operation normal.
Upon arrival, I found the kitchen refrigerator receptacle was damaged. Voltage at receptacle was reading 42 volts. After checking electrical panel, I found the breaker was failed. After replacing breaker, the refrigerator wire was reading appropriately voltage of 120 volts. Replaced receptacle at refrigerator and installed new plate as well. All issues resolved.
Gave duct cleaning and dryer cleaning estimates
Customer isn't ready at this time 25 supplies 8 returns dryer is on second floor vents out above garage
Air Conditioning Repair Service: In response to a service call highlighting an air conditioner's insufficient cooling performance, our skilled technician conducted a detailed inspection of the entire system. The investigation revealed significantly depleted refrigerant levels, impacting the unit's cooling efficiency. To address this issue comprehensively, the technician meticulously replenished the refrigerant, ensuring it reached the optimal level necessary for effective cooling. Subsequently, rigorous testing was conducted to confirm the system's capability to deliver the desired cooling capacity and comfort. Once optimal functionality was confirmed, the technician shared information about our comprehensive maintenance plans with the homeowner. This ensures not only the sustained excellent performance of their system but also provides valuable insights into preventive care and long-term efficiency. The homeowner can now enjoy reliable and efficient cooling, backed by a proactive appr
Troubleshot issue with circuit that was tripped. Found issue was related to garage switch.
No heat oil Warm air, checked system and found that the indoor fuel delivery system had failed, installed replacement and also replaced the oil nozzle, set pump pressure to 140psi, test ran. WO-TNFR249380
Club service gas warm air, changed customer supplied air filter, test ran system, inducer fan amps .6, glow bar .5, indoor fan 10.4, delta T 49, operation normal at this point.