1638 Elkton Road
Elkton, MD 21921
410-392-9350

Local Reviews

Rated 4.9 out of 5 stars based on 1118 customer reviews

Accomplished with ease

No aggravation knowledge was great Helped make big purchase easy

  • Overall Experience
  • Quality
  • Price
  • Convenience

Alway good service!!!!

Clay is just a nice person and explains the problem!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service

Trust him

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Steve was very patient. And very knowledgeable about his job. An asset to moon air.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good Job!

Joe did great quality work on time and budget

  • Overall Experience
  • Quality
  • Price
  • Convenience

Friendly Service

Polite and helpful.

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

AC service 9/10/2021 at 13 Gilbert Ct

Great service from Clay who is an excellent knowledgeable and experienced technician and who very competently and quickly identified and remedied the issue. Thanks to Clay! And thanks to Steve Moon for hiring great people! Thank you to everyone who helped me.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellence in Service

Craig never fails to provide excellent customer service. I usually stay with him and watch, mostly to learn and he is also very personable and friendly. He doesn't do a rush job, pays attention to every detail, and he noticeably takes pleasure in knowing how satisfied he is with the work he has done. He keeps our HVAC system ticking!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Timely response and problem solved

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Steven P.

Steven P. Job Checkin

Installing Daikin 7 zone mini split


tycaputo95@gmail.com

tycaputo95@gmail.com Job Checkin

Daikin 2 zone mini split for pastors office and conference room


Paul N.

Paul N. Job Checkin

Spirit oil furnace with variable speed blower


Clay K.

Clay K. Job Checkin

Dent on compressor pan, return drop loose, need to replace safety trap, warranty.


Greg H.

Greg H. Job Checkin

Found loose connection on high voltage line connection going to furnace fixed connection and test ran operation normal at this time


Clay K.

Clay K. Job Checkin

Adjust main trunk dampers


Steven P.

Steven P. Job Checkin

Installing Gold furnace and AC replacement


Greg H.

Greg H. Job Checkin

Furnace rejuv. Getting a 55 degree heat rise Cleaned burners and flame sensor. Changed filter supplied by customer. Checked eletrical conections. Draft mor amps 1.3 blower motor amps 5.1 voltage enhancement system read 8.5 our of 10 Chang it wiped down furnace. Checked tubing for clogs cleaned blower Checked heat exchanger and found no areas of concern.


Clay K.

Clay K. Job Checkin

No A/C, checked system and found that the voltage enhancement system had failed, factory spec 30/5, actual 3.3/0, installed replacement and test ran, operation normal at this time.


Clay K.

Clay K. Job Checkin

Club service A/ C, test ran system, indoor air filter is very dirty, customer will change, compressor run load amps factory spec 10.9, actual 6.3, outdoor fan full load amps factory spec 1.1, actual. 9, 20 degrees delta t, operation normal at this time.


Paul N.

Paul N. Job Checkin

Paul stopped and got a material list for install on 9/22


tycaputo95@gmail.com

tycaputo95@gmail.com Job Checkin

Gold furnace and AC replacement with duct cleaning and Air Ranger


Craig D.

Craig D. Job Checkin

Installed new control board. Test ran 10 minutes maintained temp. System normal operation at this time.


Craig D.

Craig D. Job Checkin

Outdoor unit crawl space 5/35. Fixed a wiring connection. Cleaned unit. Outdoor unit attic read 5/39.9. Checked wiring conecctions. Cleaned unit. Outdoor unit mini split coil cleaned and connections fine. Indoor unit crawl space 60 supply 76 return and 16 delta. Voltage enhancement system read 9.9 with a factory setting of 10. System normal operation at this time. Changed nozzle, strainer, gaskets and filter for oil boiler. Bled air out of system, test ran 10 minutes. System normal operation at this time.


Greg H.

Greg H. Job Checkin

Cleaned flame sensor and flame sensor. Wipe down furnace inside and outside. Blower wheel is clean checked eletrical conections. Did gas leak check found small leak at orfice tighten orfice. Checked heat exchanger found no areas of concern. Getting 55 degree heat rise draft motor amps 1.6 blower amps 4.3 operation normal at this time