1638 Elkton Road
Elkton, MD 21921
410-392-9350

Local Reviews

Rated 4.9 out of 5 stars based on 1301 customer reviews

A/C Check Up

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service and friendly

Very nice and seemed to do a really good , thorough job !

  • Overall Experience
  • Quality
  • Price
  • Convenience

Yearly inspection

Did a very nice job.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Timely, Knowlegable, Good Price


Response from Moon Air Inc.:

Thank you so much for taking the time to leave us this amazing review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome!

Punctual knowledgeable courteous and friendly technicians. Would highly recommend both of them !


Response from Moon Air Inc.:

We thank you for sharing your positive experience! It made our day.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great job


Response from Moon Air Inc.:

Thank you so much for the 5-Star Review.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

He was very nice about the whole thing it was not his fault I am going to see how this works l think I will need a new part i will let you know thank you again Matt did a very good job


Response from Moon Air Inc.:

It was a pleasure serving you and your family. We really appreciate you taking the time to share your feedback and being so open with us.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very professional


Response from Moon Air Inc.:

We are so grateful for your kind words.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Keith F

Very nice guy, enjoyed his company. Would have liked an answer/estimate from him. He said he’d confer with someone and get back to me this afternoon.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Mike did a wonderful job cleaning my air conditioning and getting me ready for the summer.


Response from Moon Air Inc.:

We are happy to hear your seasonal hvac maintenance went so well! Thanks for sharing your experience with us!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Thorough service

Thorough service and attention to detail. Believe additional work done was pricey.


Response from Moon Air Inc.:

Thank you so much for your 5-star review! We will share this with the team to let them know to keep up the amazing work.

  • Overall Experience
  • Quality
  • Price
  • Convenience

The best


Response from Moon Air Inc.:

We are so grateful for your 5-star review.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Satisfied Customer!!

Matt from Moon Air just completed my Spring AC inspection and I couldn't be more pleased. I'm all set for the coming hot weather season. The price was great and included a new filter......can't beat it!


Response from Moon Air Inc.:

We are thrilled that your spring A/C inspection went so well! We'll be sure to pass along your accolades to Matthew!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service is always awesome


Response from Moon Air Inc.:

Thank you for the 5 stars! It’s so great to hear that your hvac service was so amazing!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Matthew  F.

Matthew F. Job Checkin

Club ac rejuvenation, Supply has a temperature of 62 degrees. Return has a temperature of 81 degrees. Delta t of 19 degrees. Indoor voltage enhancement system is reading 9.9uf and with a factory spec of 10uf it is within the allowable fault. Replaced air filter with a customer supplied filter. All indoor control board connections are good. Checked evaporator coil and pan both are clean and looking good. Wd40 wipe down of the indoor unit. Outdoor voltage enhancement system is reading 38.8/4.9uf and with a factory spec of 40/5uf it is within the allowable fault. All outdoor control board connections are good. The electrical gateway is without any pitting or burn marks and looks good. Cleaned out the outdoor electrical compartment. Cleaned off outdoor coil as well as the bottom of the unit to clear out all of the drain holes. Wd40 wipe down of the outdoor unit. System is operating normally at this time.


Steven P.

Steven P. Job Checkin

Platinum AC and Furnace with Air Ranger


Clay K.

Clay K. Job Checkin

Club service AC, DELTA T =17.4 DEGREES , Compressor run Load amps factory 19.9 actual =10.6 , full load amps factory 1 actual =1, Voltage enhancement system 45 + 10 actual 46 and 9.99.


Blake B.

Blake B. Job Checkin

Club ac rejuvenation, checked air filter, delta t 20, voltage enhancement system 11.8fp 12.5 factory. Let customer know it's getting weak and will want to replace soon, checked board connections, checked blower wheel spins with no restrictions. Outdoor unit, voltage enhancement system 37.7fp 40 factory 4.71fp 5 factory fan. Opened unit and cleaned out leaves in it, coils in good shape and clean. No issues.


Matthew  F.

Matthew F. Job Checkin

See previous invoice.


Matthew  F.

Matthew F. Job Checkin

Club ac rejuvenations, Downstairs unit has a supply temperature of 48 degrees. Return has a temperature of 65 degrees. Delta t of 17 degrees. Indoor voltage enhancement system is reading 10uf and with a factory spec of 10uf it is reading perfectly. All indoor control board connections are good. Replaced air filter with a customer supplied filter. Checked evaporator coil and pan both are clean and looking good. Wd40 wipe down of the indoor unit. Outdoor voltage enhancement system is reading 43.6/4.9uf and with a factory spec of 45/5uf it is within the allowable fault. All outdoor control board connections are good. The electrical gateway is without any pitting or burn marks and looks good. Cleaned off outdoor coil as well as the bottom of the unit to clear out all of the drain holes. Wd40 wipe down of the outdoor unit. System is operating normally at this. 2nd floor unit has a supply temperature of 49 degrees. Return has a temperature of 72 degrees. Delta t of 23 degrees. Indoor volta


Mike R.

Mike R. Job Checkin

Checked air conditioner. Cleaned outdoor heat transfer media. Indoor heat transfer media, clean. Replaced customer supplied air filter. Flushed and cleaned water removal system. Checked voltage enhancement system, outdoor 45/5 actual 44.9/5.1, within factory specifications.


Keith F.

Keith F. Job Checkin

One year old AC / air handler done by moon. Wants to replace AC with heat pump. Will talk to Steve Moon and quote customer this afternoon.


Blake B.

Blake B. Job Checkin

Club ac rejuvenation, delta t 16, changed indoor air filter, checked blower wheel spinning without any restrictions, checked all board connections, cleaned eztrap, no issues. Outdoor unit, voltage enhancement system 42.06fp 45 factory, 4.8fp 5 fan factory. Coils in good shape, unit running with no issues. Wd40 wipedown.


Clay K.

Clay K. Job Checkin

Club service AC, changed customer supplied air filter, Delta T=20, Compressor run load amps factory spec 21.4, actual 15 amps, fan run load amps factory spec 1.1 amps, actual 1.0amps. Voltage enhancement system factory spec 45 /5 actual 44.1 and 5.1. Operation normal at this time.


Kyle H.

Kyle H. Job Checkin

Educational opportunity, customer had questions about lights not turning on that were plugged into outlets but each fixture had an individual switch on it which resolved concern.


Steven P.

Steven P. Job Checkin

80% furnace and AC replacement Scheduled for 5/18/22


Greg H.

Greg H. Job Checkin

Club service on central air conditioner. Recommended filter gets changed soon. Getting a 17 degree delta t. Evaporator and blower wheel are clean electrical connections are tight. Cleaned ez trap out and tested and flushed drain with a gallon of water mixed with cleaner. Wiped down outdoor unit. Condenser coil is clean. Voltage enhancement system read within factory spec of 45/5 uf.. checked for rubs outs operation is normal at this tme


Mike R.

Mike R. Job Checkin

Check air conditioner. Safety switch shut off outdoor heat transfer system due to high pressures. Spoke with Customer concerning club membership, which was purchased. Serviced air conditioner and advised and received authorization to move fencing away from outdoor heat transfer media for proper air movement. Cleaned outdoor heat transfer media. Replaced air ranger media. Air movement media clean. Flushed water removal system. Indoor heat transfer media clean.. Voltage ,enhancement, systems with factory specifications indoor10/ actual 10.1. Outdoor 30/5 actual 29.1/4,75. Customer advised of rust on high-pressure safety expansion system. Advised customer that replacement was needed. Customer authorized replacement.


Blake B.

Blake B. Job Checkin

Club ac rejuvenation, delta t 16, checked blower wheel spinning with no restrictions, checked board connections, cleaned eztrap, checked filter recommended replacing asap. Indoor coils clean, Pan clean. Outdoor unit, voltage enhancement system 19.50fp 40 factory 4.61fp 5 factory, rated way out of spec. Customer will replace, coils and bottom of unit clean. No other issues