Pooya Y.

Pooya Y.


Job Checkin

I completed a diagnostic on a Trane Gas Furnace. I determined that system was showing code 4 limit circuit fault and missing the air filter. I also discovered the rollout switch is tripped, reset switch and cycled furnace worked for about 20 minutes then tripped switch again and no flames were rolling out. went over options with customers. System was operational at time of departure.

I completed a diagnostic on a Trane Gas Furnace. I determined that system was showing code 4 limit circuit fault and missing the air filter. I also discovered the rollout switch is tripped, reset switch and cycled furnace worked for about 20 minutes then tripped switch again and no flames were rolling out. went over options with customers. System was operational at time of departure.