I completed a Full Install of a Five Star 96% Gas Furnace (Up to 100,000 BTU) Honeywell T6 Programmable Thermostat/Emerson 1F85U Five Star 16 SEER Air Conditioner (Up to 3 ton). The system is operational upon departure.
I completed a Full Install of a Five Star 96% Gas Furnace (Up to 100,000 BTU) Honeywell T6 Programmable Thermostat/Emerson 1F85U Five Star 13 SEER Air Conditioner (Up to 3 ton). The system is operational upon departure.
I completed a full install on a Five Star gas furnace and a Five Star 16 SEER 3.5 ton air conditioner. I cycled and monitored the system. Operating normally at this time.
I completed the scheduled maintenance agreement cooling tune up on a Carrier 13 SEER 2.5 ton air conditioner. I visually inspected the unit. Checked voltages, amps and pressures. I inspected the evaporator coil. I checked the temperature difference across the coil. Inspected heat pump. Checked refrigerant charge, voltages and amps. I rinsed the condenser coils with water. Cycled and monitored system. All operating normally at this time.
I completed the scheduled maintenance agreement cooling tune up on a air conditioner. I visually inspected the unit. Checked voltages, amps and pressures. I inspected the evaporator coil. I checked the temperature difference across the coil. Inspected heat pump. Checked refrigerant charge, voltages and amps. I rinsed the condenser coils with water. Cycled and monitored system. All operating normally at this time.
I completed the scheduled maintenance agreement cooling tune up on a Carrier 13 SEER 2.5 ton air conditioner. I visually inspected the unit. Checked voltages, amps and pressures. I inspected the evaporator coil. I checked the temperature difference across the coil. Inspected heat pump. Checked refrigerant charge, voltages and amps. I rinsed the condenser coils with water. Cycled and monitored system. All operating normally at this time.
I completed a spring tune-up tune on a Goodman air conditioner. I visually inspected the furnace. Checked voltage and amps. I inspected the evaporator coil. I checked the temperature difference across the coil. Checked refrigerant charge, voltages and amps. I rinsed the condenser coils with water. Cycled and monitored the system. Operating normally at this time.
I completed a full install on a Five Star gas furnace and a Five Star 16 SEER 2.5 ton air conditioner. Operating normally at this time. Included with the installation is a free 1 year service maintenance agreement.
I completed a full install on a Carrier 80% gas furnace and a Carrier 16 SEER 2.5 ton air conditioner. Operating normally at this time. Included with the installation is a free 1 year service maintenance agreement.
I completed a half install on a Five Star 16 SEER 3.5 ton air conditioner. Operating normally at this time. Included with the installation is a free 1 year service maintenance agreement.
I completed the scheduled maintenance agreement cooling tune up on a Five Star 17 SEER 3 ton air conditioner. I visually inspected the unit. Checked voltages, amps and pressures. I inspected the evaporator coil. I checked the temperature difference across the coil. Inspected heat pump. Checked refrigerant charge, voltages and amps. I rinsed the condenser coils with water. Cycled and monitored system. All operating normally at this time.
I completed the scheduled maintenance agreement cooling tune up on a Carrier 17 SEER 4 ton air conditioner. I visually inspected the unit. Checked voltages, amps and pressures. I inspected the evaporator coil. I checked the temperature difference across the coil. Inspected heat pump. Checked refrigerant charge, voltages and amps. I rinsed the condenser coils with water. Cycled and monitored system. All operating normally at this time.
I completed the scheduled maintenance agreement cooling tune up on a Bryant air conditioner. I visually inspected the unit. Checked voltages, amps and pressures. I inspected the evaporator coil. I checked the temperature difference across the coil. Inspected heat pump. Checked refrigerant charge, voltages and amps. I rinsed the condenser coils with water. Cycled and monitored system. All operating normally at this time.
I completed the scheduled maintenance agreement cooling tune up on a air conditioner. I visually inspected the unit. Checked voltages, amps and pressures. I inspected the evaporator coil. I checked the temperature difference across the coil. Inspected heat pump. Checked refrigerant charge, voltages and amps. I rinsed the condenser coils with water. Cycled and monitored system. All operating normally at this time.
I completed a diagnostic and found that the capacitor was not reading properly. I replaced the capacitor. System operational upon departure.