Excellent Service

Very thorough summer start-up of a new AC unit. Found some areas that needed some adjustment and AC is running fine.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great and proffessional Service! Thanks, Dionte

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Hayden was polite and knowledgeable about my systems. Pleasure to meet him.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

Fredy and Adiel did a great job! Wonderful representatives of the company. Thank guys!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service

The installation took two trips because the tech didn't have the required parts with him the first time.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

NICE Home Services responded quickly when my AC went out during a heat wave. The service was great and very informative.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for ashburn, va

Fredy T.

Fredy T. Job Checkin

Cooling safety inspection and maintenance. Tuned the thermostat to cooling then dropped the temperature to 50f, inspected the indoor system, pulled out the filter and inspected the duct system, flushed the condensation drain line and turned off the humidifier. Inspected the blower assembly and the evaporator coil. Checked the refrigerant pressures and added 3 lbs of R 410a refrigerant, leveled the outdoor system then cycled. Job complete.


Kyle G.

Kyle G. Job Checkin

1)hvac diagnostic 2) client said that system is not cooling I confirmed both systems are low on refrigerant and main system is extremely low, I advised to see comfort specialist to upgrade equipment due to age,efficiency and conditions, client authorized. 3)Job not complete, comfort specialist will be going to clients home.


Kyle G.

Kyle G. Job Checkin

Air scrubber bulb 1)tune up 2) I checked all capacitors and inspected blower wheel assembly I also checked for proper delta t and confirmed system is cooling at this time, I advised to install new air scrubber bulb to sanitize air 99.9% client authorized repair. 3)Job complete, left thermostat on desired temperature.


Rolando M.

Rolando M. Job Checkin

This option is the least expensive option that would safely address what we were called out for. *refrigerant recharge Arrived at clients foe two system and water heater maintenance. Set thermostat to cooling. Checked for proper delta T. Inspected blower wheel and air filters. Blower wheel had minimal build up. Replaced both air filters in the return grilles. Flushed condensate drain line and ensured free of dirt and debris. Checked electrical components and inspected evaporator coil. Made my way to downstairs furnace. Set thermostat to cooling. Checked blower wheel which was 40% restricted. Air filter was 25% restricted. Flushed condensate drain line and cleared out with ez trap brush.evaporator coil was good. Washed both outdoor coils. Checked electrical components and system pressures. The lower level system was low on charge. Client approved recharging system to correct specifications. Systems are operational. Job complete.


Kyle G.

Kyle G. Job Checkin

Capacitor 1)tune up 2) I checked all capacitors and inspected blower wheel assembly I also checked for proper delta t and confirmed downstairs capacitor is weak and advised to replace capacitor to ensure proper operations, client authorized repairs, also outside capacitor is faulty and needs to be replaced, client declined service. 3)Job complete, left thermostats on desired temperature.


hmarshall@myindoorclimate.com

hmarshall@myindoorclimate.com Job Checkin

Performed water heater tune up. Flushed water heater. Performed cooling tune up. Flushed drain line. Cleaned condenser coil. Checked all major components and system operation. Air filter 100% impacted and in need of changing ASAP. Found blower wheel slightly impacted, evaporator coil clean. Recommend Teflon treatments for both blower and coil. No flood protection besides pan float, recommend wet switch flood protection unit to prevent costly water damage. No power surge protection inside or out, recommend power surge protection units for indoor and outdoor unit to protect motors, compressor and board from power surge damage. Found Schrader valve weeping, tightened it and it is no longer leaking. Found system refrigerant charge low, charged with 1lb of R410a. Recommend Air Scrubber to clean and sanitize the air and surfaces in home.


Dionte W.

Dionte W. Job Checkin

This option is the least expensive option that would safely address what we were called out for.


hmarshall@myindoorclimate.com

hmarshall@myindoorclimate.com Job Checkin

Performed cooling tune up on 2 systems. Flushed drain lines and cleaned condenser coils. Checked all major components. Wrapped condensers to perform cold weather check. System 1 downstairs: Found 30amp outdoor disconnect broken, handle missing and plug is fused to contacts. Recommend replacing disconnect immediately. Condenser fan motor has signs of corrosion. Found floor drain is backing up, may need plumber out to clear drain. No surge protection. System is 14 years old. System 2 upstairs: No surge protection for outdoor unit or indoor variable speed motor. System is nearing end of eligibility for extended warranty. Recommend 10 year parts and labor extended warranty. The system is operating properly at this time. Water heater: Unable to flush water heater because customer said valve is broken and cannot be opened or it will leak. Water heater is 15 years old. Recommend replacing water heater.


Fredy T.

Fredy T. Job Checkin

Cooling safety inspection and maintenance. Turned the thermostat from Heating to cooling then dropped the temperature then verified cooling operation, went in the attic to flush the condensate drain line and to inspect bathe air handler, inspected the drain line and flushed with 1 gallon of water , inspected the evaporator coil and the blower assembly, advised the client to have us install an uv light to keep his coil clean. Inspected the basement system and replaced the filter. Cleaned both coils and checked operation, the water heater is in a poor condition advised the client that the water heater cab bust any time or day soon. The client wants to have his solutions on a new Hvac system and water heater. Tune up complete.


Ashley G.

Ashley G. Job Checkin

Diagnostic for rattling noise on new system found fuse box screws not tighten all the way secured box. Installed ez trap and secured wires. Offered extended warranty and talked bout IAQs. Checked for water leaks system working normally at this time


Dionte W.

Dionte W. Job Checkin

Standard 96% 2-stage & variable speed fan 17 seer Air Conditioner and matched coil 50 Gallon water heater Smart thermostat Ultraviolet light air and object purification systems Water protection systems 5-year parts and labor warranty (can't write a check) 5-year maintenance plan membership professional installation


Fredy T.

Fredy T. Job Checkin

* mini turbo capacitor replacement for your blower motor * Humidifier cleaning/ service and pad replacement Heating safety inspection and maintenance, turned the thermostat higher than the room temperature. Pulled and inspected the air filter, inspected the blower assembly and the heat exchanger no visible cracks or holes, checked for gas leaks and cleaned the flame sensor, found weak run capacitor rated at 5uf actual reading 3.25, also found humidifier infested with biological growth advised the client to have us clean and to replace the humidifier pad. Replied the run capacitor and cleaned the humidifier, tested operation and checked for carbon monoxide, final cycled the system. Job complete.


Fredy T.

Fredy T. Job Checkin

Nest thermostat installation Removed the old Honeywell non programmable thermostat then installed a Nest E smart thermostat, checked operation in cooling and heating mode, showed the client how to use it and final cycled the system. Job complete.


Darius  L.

Darius L. Job Checkin

Heat Tune Up Upon Arrival Increased the temperature to ensure the system was function Check the temperature on the supply/return Cleaned/Removed flame sensor Inspected gas line for leaks Changed air filter Inspected gas valve Amperage is low on capacitor Gas furnace is very old blower motor is extremely dirty Amperage is low on the capacitor Return box is covered with dust and dirt Visible no insulation in attic (beams are exposed) Customer has mention the far room upstairs gets very cool in the winter very hot during the summer


Ashley G.

Ashley G. Job Checkin

Diagnostic inducer motor is over heating. Works for a while then turns off when it cools down. Checked amps and limit switches. Capacitor for blower motor is weak needs to be replaced. Customer will call his home insurance advised customer to look into replace system silver it’s from 1999 and needs repair. Left system as is