James L.

James L. Job Checkin

170469


Randal S.

Randal S. Job Checkin

I completed a diagnostic on a Bryant A/C. I found outdoor unit is humming. The capacitor has blown so I replaced it. Cycled and monitored. System operating at this time.


Shane W.

Shane W. Job Checkin

I completed a full install with a Five Star 3 Ton Multi-Speed Air Handler - FSGRUF and a Five Star 14 SEER, 3 Ton Heat Pump - FSGSZ14

I completed a full install with a Five Star 3 Ton Multi-Speed Air Handler - FSGRUF and a Five Star 14 SEER, 3 Ton Heat Pump - FSGSZ14

Donald R.

Donald R. Job Checkin

System needs new gas valve.

System needs new gas valve.

Donald R.

Donald R. Job Checkin

Replace warranty Gas Valve and checked for gas leaks with a electronic leak doctor ad bubbles.

Replace warranty Gas Valve and checked for gas leaks with a electronic leak doctor ad bubbles.

Donald R.

Donald R. Job Checkin

No heat- Upon arrival found system locked out on a flame proving fault. Customer showed me a video on his phone where the igniter came on but it didn’t light. Cycled furnace found that the gas valve is getting 24 volts but not opening every now and then. This is due to the gas valve sticking closed every now and then. replaced gas valve system OPERATING AT THIS TIME

No heat- Upon arrival found system locked out on a flame proving fault. Customer showed me a video on his phone where the igniter came on but it didn’t light. Cycled furnace found that the gas valve is getting 24 volts but not opening every now and then. This is due to the gas valve sticking closed every now and then. replaced gas valve system OPERATING AT THIS TIME

Donald R.

Donald R. Job Checkin

Diagnostic Service Call. No heat upon arrival customer stated he removed the flame sensor and cleaned it and it starting working all day. Upon further inspection found the flame sensor not aligned with the burner causing improper readings. I aligned the flame sensor up and re-attached the ground that was very loose on the furnace cycled system multiple times found no issues at this time.

Diagnostic Service Call. No heat upon arrival customer stated he removed the flame sensor and cleaned it and it starting working all day. Upon further inspection found the flame sensor not aligned with the burner causing improper readings. I aligned the flame sensor up and re-attached the ground that was very loose on the furnace cycled system multiple times found no issues at this time.