Technician diagnosed faulty circuit board that was shorting out on a Comfortmaker furnace. The customer chose to attempt to purchase a board on his own and repair it himself.

Technician diagnosed faulty circuit board that was shorting out on a Comfortmaker furnace. The customer chose to attempt to purchase a board on his own and repair it himself.

Christopher M.

Christopher M. Job Checkin

Replaced in warranty part on BRYANT furnace. Intake Nipple Kit

Replaced in warranty part on BRYANT furnace. Intake Nipple Kit

Greg N.

Greg N. Job Checkin

Diagnostic Service Call on 2015 Bryant Furnace

Diagnostic Service Call on 2015 Bryant Furnace

Haidar H.

Haidar H. Job Checkin

Leak at discharge line connecting to the condenser repaired and nitrogen level tested. System performing within manufacture specifications.

Leak at discharge line connecting to the condenser repaired and nitrogen level tested. System performing within manufacture specifications.

Haidar H.

Haidar H. Job Checkin

Performed diagnostic service on Bryant a/c unit. System low on refrigerant due to a leak right at the discharge line connecting to the condenser. filled system for temporary cooling until leak can be fixed.

Performed diagnostic service on Bryant a/c unit. System low on refrigerant due to a leak right at the discharge line connecting to the condenser.

filled system for temporary cooling until leak can be fixed.

Kendra H.

Kendra H. Job Checkin


Tammy S.

Tammy S. Job Checkin


Tammy S.

Tammy S. Job Checkin


Scott G.

Scott G. Job Checkin

Service call on TEMPSTAR a/c unit. Unit not cooling found 70/5 capacitor with no charge and disconnect with some light damage.

Service call on TEMPSTAR a/c unit. Unit not cooling

found 70/5 capacitor with no charge and disconnect with some light damage.

Isaiah C.

Isaiah C. Job Checkin

Goodman 1999 unit was froze over, thawed out added contractor and 2 pounds of freon


Kara H.

Kara H. Job Checkin

Replaced the evaporator coil on a 2017 Carrier Air Conditioning System.


Kendra H.

Kendra H. Job Checkin


Scott G.

Scott G. Job Checkin

performed service on TRANE A/C unit. Checked pressures from winter install.

performed service on TRANE A/C unit.  Checked pressures from winter install.

Christopher M.

Christopher M. Job Checkin

added 2lbs. R410a to AC unit

added 2lbs. R410a  to AC unit

Scott G.

Scott G. Job Checkin

Upon diagnostic visit, found unit sub cool at 1.0. Previous owner did install is AC themselves. No paperwork on install. Not sure if vacuum pump was used or how the install went. Came to the conclusion that the unit wasn't properly charged at time of install.

Upon diagnostic visit, found unit sub cool at 1.0. Previous owner did install is AC themselves. No paperwork on install.  Not sure if vacuum pump was used or how the install went. Came to the conclusion that the unit wasn't properly charged at time of install.