A/C Diagnostic "furnace leaking water" Suction line insulation had come loose near the txv and the AC. Causing water to condensate on the cold copper suction line and was dripping. Replaced and secured suction line insulation near the TXV and the AC. Check charge under load added 1lb 410a. System is operating properly at this time. Repaired at no cost due to <1 yr old system. 10/10, seen no evidence of a leak. Weigh in charge at last visit likely low due to liquid line length. AC is operating properly at this time.
On arrival I found the system void of 410 I ran short of nitrogen and passed the call to Josh Adkins to coordinate a timely return for the repair.
Upon arrival I replaced a pair of 40 AMP Buss Fuses. The system is operational upon departure.
Upon arrival I completed diagnostics and found blown fuse on ac. Talked about replacement. Homeowner has AC in Garage but is R-22 which is obsolete. Wants to do fuses at this time.
completed full install of a Amana 96% 2-Stage 60,000 BTU Down-Flow Gas Furnace/Amana 16 SEER 2-Stage 2 Ton Air Conditioner/Replace Condensate Pump (Vinyl Tubing Extra) Kit/006-remove/out of place/IWAVE/R Price includes new furnace, thermostat, required venting, required electrical, required gas piping, required duct adjustment, removal of old equipment, tax and installation complete. also a lifetime warranty on unit replacement and a 10 year warranty on parts
I completed a diagnostic. I found system not sending 24volts to the gas valve no safety's are intertwined with the valve indicating the board has failed.