Techs were great, efficient , courteous!
Response from Ragsdale Heating and Air Conditioning Inc:
We truly appreciate your business and your feedback thanks, Kristian Hall Happiness Coordinator at Ragsdale Heating, Air and Plumbing.
Response from Ragsdale Heating and Air Conditioning Inc:
Thanks for taking the time to write in a review on our services. It is always appreciated to get positive feedback on our team. Kristian Hall Happiness Coordinator at Ragsdale Heating, Air and Plumbing.
Stephen is great to work with.
Response from Ragsdale Heating and Air Conditioning Inc:
Thanks member for the great report we appreciate you taking the time to write about our service. Stephen loves this kind of feedback too. Kristian hall Happiness Coordinator at Ragsdale Heating, Air and Plumbing
Steven diagnosed my issue and made the correction quickly and professionally. He very personable and we had much in common. If possible, please dispatch him the next time I need service.
Response from Ragsdale Heating and Air Conditioning Inc:
Thanks member for the great report we appreciate you taking the time to write about our service. Steven loves this kind of feedback too. Kristian hall Happiness Coordinator at Ragsdale Heating, Air and Plumbing
We were in need of a new unit and not sure if we were making the right decisions. Ragsdale helped us decide and guided us in the right direction. As long as Ragsdale is in business, we won't use anyone else!!!
Found system low on freon tried to add a little freon but pressure would not change. Found blowing leak in the evap coil and bad TXV will need to replace.
New Residential Planned Maintenance For (1) Year.
performed Ragsdale Heating air and plumbing maintenance and cleaning visit.
Prepaid Residential Planned Maintenance Visit.
Completed Gold Heat Pump maintenance/cleaning visit. ODT 40F. All items checked in accordance with fall PM checklist, to include but not limited to: checked operation, emergency heat mode, aux. heat, amp draws, blower, coil, controls, electrical, safeties, temperature rise & inspect visible ductwork on the indoor unit. Checked outdoor electrical, controls, motor, refrigerant charge, defrost cycle, amp draws & inspect coil
Equipment discovered does not match equipment originally discovered. Most likely cause was the sim chips were loose. I took out chips and reinstalled. Problem is gone at this time. Problem may still be in thermostat. If it reoccurs, we may need to replace thermostat.
Carrier 3 Ton Infinity 18VS Variable Stage High Efficiency Heat Pump Carrier Infinity Variable Speed High Efficiency Air Handling Unit Carrier 10 KW Auxiliary Heater Carrier Infinity Touch Controller -True Dehumidification -Fully Programmable -Automatic Changeover -Touch Screen
Second floor system icing due to low refrigerant charge. Located leak on evaporator coil visually (refrigerant oil). Oil also present on top of accumulator at heat pump. Recommend replacing system due to age, high cost of repairs and R-22 Phase out. Added 2 pounds R-22 so customer will have cooling.
Service Call/Diagnostic, system not cooling. Checked for ice on evap coil. Checked refrigerant charge. Suction temp below freezing. Added R-410 but no help. Ran system in heat mode then switched to ac. TXV failed. Replaced TXV system is now cooling properly.
Found that air handler is trying to pull more air through louvered doors that it physically can. Unit was pulling air through the drain and it was creating a knocking sound through the bathtub drain trap as it was pulling air through the bathtub drain.
Service Call/Diagnostic, found drain line clogged, cut line and used nitrogen to clear. Ragsdale can not be responsible for any water damage due to no flood safety protection. Also found filter very dirty and clogged, advised customer to replace. And found evap coil very oily, customer has had to add freon in the past.
No one was there to tell me what system had been doing but I found it 2 lbs low of 410 a refrigerant did leak search and found leak in valve cores replaced valve cores and recharged unit system is cooling at this time
Found blower capacitor was weak . Also system was low of freon. Added just under 4 pounds r22 to the system. No warranty on freon added.
Service Call/ Diagnostic. Changed out ultravation media filter. Replace condensate pump.