Removed 2.5 ton r-22 condenser replaced with proper size 4 Ton condenser to match proper indoor evaporator coil , increased indoor return to 20x30 ,flushed line set ,restarted and set charge per. Manufacturers specifications. Thank you for choosing Ray and Son to provide and enhance your indoor climate comfort !