Pennie S.

Pennie S. Job Checkin

Installed new blower motor and squirrel cage, control board and capacitor to the furnace. All working at this time. Freon check indicated a pound and a half short of refrigerant 410A. Split the difference of 16° all good at this time watching and advise.


Pennie S.

Pennie S. Job Checkin

Test of system finds diagnosis as airflow not getting downstairs. Further testing finds zone damper motor inoperable causing downstairs not to cool correctly. New damper motor 16" will be needed to permanently fix problem. Cost provided to homeowner.


Pennie S.

Pennie S. Job Checkin

Recovered freon from old 4-ton Ac unit & Removed. Installed new 16 Seer 4-ton R410a Rheem AC Turned unit on and added 1/2 lb R410a and checked. System running a perfect at this time.


Pennie S.

Pennie S. Job Checkin

Test of system finds diagnosis as airflow not getting downstairs. Further testing finds zone damper motor inoperable causing downstairs not to cool correctly. New damper motor 16" will be needed to permanently fix problem, provided costs.


Pennie S.

Pennie S. Job Checkin

5/2-Recovered freon from old AC system. Disassembled coil, duct transition, electrical, and AC unit. Installed new Rheem 14 Seer 5 Ton 3-phase system. Added new Wifi Honeywell Programmable thermostat. Installed new ClearVue self cleaning condensate pump. 5/12 Once electrician finished returned to home. Started 3-phase unit up.


Pennie S.

Pennie S. Job Checkin

Uninstalled old unit and Installed new Rheem 14 Seer 5 Ton 3-phase 230 volt AC, Evaporator Coil, Rheem 1 phase 230 volt air handler (14 Seer up to 16 Seer). Added new Wifi Honeywell Programmable thermostat. Electrician to wire 3-phase AC 240 volt. Electrician to wire 1-phase air handler 240 volt. Returned to property after electrician completed wiring and turned unit on. all ok at this time.


Pennie S.

Pennie S. Job Checkin

system checked contacting Goodman


Pennie S.

Pennie S. Job Checkin

Cleared drain line. Added algae tabs to drain pan. Added 2.5 R22 freon. Unit now running a 12° superheat. All okay at this time. Sulik


Pennie S.

Pennie S. Job Checkin

Gas off at home.


Pennie S.

Pennie S. Job Checkin

Installed new compressor, drier, and capacitor provided by warranty company. Added 18 lbs R22 freon. Watch and advise.


Pennie S.

Pennie S. Job Checkin

Warranty requested search completed. System is not low on freon, requires compressor replacement only.


Pennie S.

Pennie S. Job Checkin

Installed new compressor and capacitor. Added 11 lbs R22 freon.


Pennie S.

Pennie S. Job Checkin

System low on feron. pricing provided. Financing.


Pennie S.

Pennie S. Job Checkin

Test of system finds unit low on freon. Coil needs replaced advising cchs.


Pennie S.

Pennie S. Job Checkin

Replaced malfunctioning thermostat. Melted ice from indoor coil and added 2 lbs R22 freon.