Water leak, Found system been leaking for a while emergency drain pan rotted through and evaporator coil coming apart from rust, Also very low refrigerant levels found leak in coil Client aware system leaking refrigerant wants temporary fix till new install on 9/1/16 **No warranty on refrigerant ** Recharge and balance refrigerant Low 71 Psig Super-heat 32 High 228 Psig Sub Cool 25 Ck/change filter Measure temperature difference 18'F Outdoor temp 94'F Client Aware system needs further attention for permanent fix/repair also made aware system can freeze and leak water causing property damage Suggested not to run equipment leaking and rotting of emergency pan Recommend upgrading equipment Temporary fix till installed $425 value with new install