3981 Cleveland Ave
Columbus, OH 43224
614-475-1800

Local Reviews
for galloway, oh

Rated 5.0 out of 5 stars based on 3 customer reviews

Great Service

Service was great as always.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Josh was great


Response from Sears Heating & Cooling:

Thank you for your review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for galloway, oh

Josh S.

Josh S. Job Checkin

Lennox ac check 2016 r410 40/5 cap below spec

Lennox ac check 2016 r410 40/5 cap below spec

Josh S.

Josh S. Job Checkin

Ac check on Goodman 2016 HP. 2-1/2 ton 13 seer

Ac check on Goodman 2016 HP. 2-1/2 ton 13 seer

Josh S.

Josh S. Job Checkin

Ac check on 2015 Bryant with ICP coil. Filter 16-25-1. Lots of cottonwood

Ac check on 2015 Bryant with ICP coil.  Filter 16-25-1. Lots of cottonwood

Josh S.

Josh S. Job Checkin

Ac check in the country Bryant 2015

Ac check in the country Bryant 2015

Mike B.

Mike B. Job Checkin

Performing maintenance on a 2011 Bryant air conditioner.

Performing maintenance on a 2011 Bryant air conditioner.

Mike B.

Mike B. Job Checkin

Performing maintenance on a 1988 rheem air conditioner.

Performing maintenance on a 1988 rheem air conditioner.

Josh S.

Josh S. Job Checkin

Ac check on ac Trane 2003 r22 14-25-1 filter

Ac check on ac Trane 2003 r22 14-25-1 filter

Mike B.

Mike B. Job Checkin

Completed mechanical, safety, and performance test on air conditioner. Found concern with voltage enhancement system being out of Manufacturers specifications and weak. Also found voltage distribution center has pitted contacts and starting to causing burning and charring. Went over options on page hn13. Chose hn13 c to do both repairs. Replaced faulty voltage enhancing system and upgraded to turbo enhancing system. Replaced burnt distribution system. Cycled and tested. All okay at this time.

Completed mechanical, safety, and performance test on air conditioner. Found concern with voltage enhancement system being out of Manufacturers specifications and weak. Also found voltage distribution center has pitted contacts and starting to causing burning and charring.  Went over options on page hn13. Chose hn13 c to do both repairs. Replaced faulty voltage enhancing system and upgraded to turbo enhancing system. Replaced burnt distribution system. Cycled and tested. All okay at this time.

Josh S.

Josh S. Job Checkin

Furnace check on Armstrong the brave. System is single stage 2009 80%

Furnace check on Armstrong the brave.  System is single stage 2009 80%

Ramon R.

Ramon R. Job Checkin

Performed furnace maintenance and safety check on Bryant unit. Provided estimate for steam, fan powered and by-pass humidifiers.


Mike B.

Mike B. Job Checkin

Performing maintenance on a. 2003 trane gas furnace.

Performing maintenance on a. 2003 trane gas furnace.

Ramon R.

Ramon R. Job Checkin

Replaced failed contactor and cleaned up wiring terminal ends


Mike B.

Mike B. Job Checkin

Performing maintenance on a. 1993 Armstrong air conditioner.

Performing maintenance on a. 1993 Armstrong air conditioner.

Josh S.

Josh S. Job Checkin

Scac capacitor is 40/5 and I replaced due to being at 36/5

Scac capacitor is 40/5 and I replaced due to being at 36/5

Josh S.

Josh S. Job Checkin

Unit not cooling elk 80 degrees inside Lo on charge Added r410 Replaced voltage absorption system Cleaned outdoor unit and tightened wiring 140 low 330 high 15 superheat 20 split temp Pulling humidity out Moving soon

Unit not cooling elk 
80 degrees inside 
Lo on charge 
Added r410 
Replaced voltage absorption system 
Cleaned outdoor unit and tightened wiring 
140 low
330 high 
15 superheat 
20 split temp 
Pulling humidity out 
Moving soon