3981 Cleveland Ave
Columbus, OH 43224
614-475-1800

Local Reviews

Rated 5.0 out of 5 stars based on 283 customer reviews

Very thorough and professional service

Josh was great. He answered all my questions and provided very good advice on a new system we plan to do next year.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Best service!

Josh has come to our home twice to service our Mitsubishi mini- split. He is very thorough, professional, personable and remembered our dogs name and gave her a treat! She loves when he visits and she is picky!! We will continue to request Josh and also plan to transfer our other service needs ( ac and furnace) to Sears because of Josh. He is the Best!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Well Done

Nice guy, gave me the details I needed to make an informed decision, did the work thoroughly and quickly, easy to work with. Good experience.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

Service call placed and someone was out within a few hours. Love Sears HC! They have great installers and awesome customer service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Josh arrived at the time he said he would. He was very nice and professional. He did a good job explaining what was wrong with my AC and fixed it in a very timely fashion. It was greatly appreciated since it was miserably hot outside! I also really appreciate him not trying to “upsell” -I would definitely have him come back if I needed assistance again

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great visit

Josh came out to diagnose my AC not kicking on. He quickly traced the issue, and cleaned the outside unit and did a little upgrade to help reduce west and voltage on startup. Very professional and friendly. Would highly recommend him and Sears H&C!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Josh was great. He was very quick and explained what he was doing thoroughly. I felt that he was honest and he was also great with our dog!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick service

Joshua was very knowledgeable and I felt confident with his services.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service and Pricing.

Josh fixed the issue in no time at all. He arrived on time and happily and candidly answered questions with patience.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

The service was quick and professional. I appreciated being given a menu of options to decide between when choosing the service that was best for us. Answered all my questions and was personable and thorough.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Joel  T.

Joel T. Job Checkin

Sold new furnace to replace failed 19 year old unit.

Sold new furnace to replace failed 19 year old unit.

Ramon R.

Ramon R. Job Checkin

Estimate for furn replacement


Ramon R.

Ramon R. Job Checkin

Diagnosed excess humidity in basement/crawl space area, duct work sweating recommended Aprilaire whole house humidifier. Estimate for installing ductless Mitsubishi minispilt system.


Mike B.

Mike B. Job Checkin

Performing maintenance on a. 2015 comfortmaker air conditioner.

Performing maintenance on a. 2015 comfortmaker air conditioner.

Mike B.

Mike B. Job Checkin

2020 comfortmaker air conditioner. Customer mentioned unit struggling to keep up on hot days. Current delta t is 18 degrees. Checked refrigerant charge. System currently operating with 8 degrees sub cooling, but evap coil is boiling off at 34 degrees. Filter is clean and registers are all open. Customer had ducts cleaned roughly 3 months ago and noticed this issue starting to occur. I set dip switches to maximize airflow and added an ounce of 410 to achieve 9.8 degrees of sub cooling. Coil is now boiling at 41 degrees and temp drop is 18 degrees. This should increase dehumidification to allow for more comfortable air with no issue reaching set point on the thermostat.

2020 comfortmaker air conditioner. Customer mentioned unit struggling to keep up on hot days. Current delta t is 18 degrees. Checked refrigerant charge. System currently operating with 8 degrees sub cooling, but evap coil is boiling off at 34 degrees. Filter is clean and registers are all open. Customer had ducts cleaned roughly 3 months ago and noticed this issue starting to occur. I set dip switches to maximize airflow and added an ounce of 410 to achieve 9.8 degrees of sub cooling. Coil is now boiling at 41 degrees and temp drop is 18 degrees. This should increase dehumidification to allow for more comfortable air with no issue reaching set point on the thermostat.

Joel  T.

Joel T. Job Checkin

Ac maintenance inspection including cleaning condenser coil, checking electrical connections and cycling equipment to ensure proper operation.

Ac maintenance inspection including cleaning condenser coil, checking electrical connections and cycling equipment to ensure proper operation.

Jamie S.

Jamie S. Job Checkin

Cost to replace air condition. Cost to install Bryant air condition

Cost to replace air condition. Cost to install Bryant air condition

Cody C.

Cody C. Job Checkin

AC check on a 2014 Rheem air conditioner. Completed performance check, safety check, mechanical check. Everything is working properly at this time.


Mike B.

Mike B. Job Checkin

Performing maintenance on a 2010 Lennox air conditioner.

Performing maintenance on a 2010 Lennox air conditioner.

Wally T.

Wally T. Job Checkin

Annual maintenance check on a Ruud heat pump


Ramon R.

Ramon R. Job Checkin

Diagnosed failed condenser fan motor


Joel  T.

Joel T. Job Checkin

Ac maintenance inspection

Ac maintenance inspection

Mike B.

Mike B. Job Checkin

Performing maintenance on a 2017 rheem air conditioner.

Performing maintenance on a 2017 rheem air conditioner.

Ramon R.

Ramon R. Job Checkin

Replaced failed capacitor on Bryant unit


Mike B.

Mike B. Job Checkin

2008 Bryant t air conditioner. Found voltage a enhancement system failed. It is a special sized component requiring xl cap. Went over options on page hn11. Customer chose hn11a. When testing system found no power. Pushomatic breaker tripped when voltage enhancement system failed. Reset breaker and tested system. 19 degree temp drop. All okay at this time.

2008 Bryant t air conditioner. Found voltage a enhancement system failed. It is a special sized component requiring xl cap. Went over options on page hn11. Customer chose hn11a. When testing system found no power. Pushomatic breaker tripped when voltage enhancement system failed. Reset breaker and tested system. 19 degree temp drop. All okay at this time.