I always feel Pete will follow through to get the job done. Still have a couple of things left to complete.
Joseph and Pete went above and beyond to get our AC issue taken care of. Wonderful company to work with. We highly recommend them.
Pete the technician was awesome! He was on time and able to diagnose the problem quickly. South Coast Heat and Air really go above and beyond.
Came out and found the issue in 2 minutes upon arrival. Pete was professional and courteous.
Pete, is down to earth, professional, and provides accurate assessments during troubleshooting. Pete never tried to upsale during any of the service visits to our home. He quickly and accurately identified the issue with our A/C unit. Prior to leaving our home Pete did a work around which allowed us to have cool air over the weekend while we waited for the ordered part to arrive to fix our A/C.
Pete was friendly and professional. Asked about my concerns and answered questions.
Joseph was very knowledgeable and provided great service. Fixed issue in timely manner. Pricing very economicial.
Claim # 44581 found primary drain plugged up blew out drain checked operations authorization number 2119502
Adjusted head on bracket reinsulated refrigerant lines cleaned up head and wall
Ruud 16 seer 3.5 Ton Electric System - 10 Year parts/10 Year labor
Did static pressure test static pressure as 10 coil was at 36° when I arrive I put blower into high speed my coil temp up to 40°
Check system out check Freon levels took temperature differential checked all ductwork checked all electrical connections
Work Order # AHW-95051 Sound system low on freon I did a leak search and found leak and evaporator coil
Check system check Freon levels freon levels perfect check incoming and outgoing air incoming Air at 66° out going air at 46° coil is clean amperage on blower good ductwork all sealed no float switches unit running perfectly at this moment
Pulled old coil out and start new coil did pressure test and pull vacuum and recharge system
Capacitor in condenser unit failed and is no longer in range which caused compressor not to run. Compressor is running at 21.3 amps which is close to its max operating range.
Preformed tune up maintenance on system. The system is working very well, all components are with in range and functioning properly. System has a 20 ° temperature split. Air handler compartment is very clean and maintained. Compressor, blower motor and fan motor all with in range of amp measurements, indoor and outdoor capacitors are also within range.
Screen on thermostat is dull and hard to read, thermostat button is also not responsive at all times.
I found system with no freon check for leaks found leak and evaporator coil major leak in evaporator coil
Performed diagnostic on system, it is determined that the blower motor has failed and is no longer pushing air. Won’t be able to give accurate estimate for repair till Monday when parts stores are open.
Removed old compressor and dryer install new compressor and dryer did nitrogen test pull the vacuum and recharge system