5712 Highland Rd
Santa Fe, TX 77517
346-326-2665

Local Reviews
for la porte, tx

Rated 5.0 out of 5 stars based on 4 customer reviews

great service

From estimate to completion we received great service. The team was courteous, very efficient and made repairs quickly without leaving any debris behind. Thank you for a great job.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Saved the day!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service tech

Alex was very thorough & very nice, he also explained everything which is really important. Great person!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good work

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for la porte, tx

Pete L.

Pete L. Job Checkin

Check blower motor amperage check capacitor capacitor rated at 15 microfarads capacitor showing at 13.2 homeowner said he changed it himself checked all electrical contacts check primary and secondary drain check all the ductwork check amperage on compressor and condenser fan motor check capacitor and contactor check Freon levels found free on low , no signs of leaks recharge system


Pete L.

Pete L. Job Checkin

Found bad control board needs to be replaced, replace control board unit in warranty no charge


Matt P.

Matt P. Job Checkin

Condenser capacitor is reading 37 should be at 45 plus or minus 6%


Joseph S.

Joseph S. Job Checkin

The customer was just price shopping and needed some ballparks to discuss with her husband. Will call back if seriously interested.


Pete L.

Pete L. Job Checkin

Checked outside unit found condenser fan motor running at 1.2 amps and it's rated at 1.3 blew out main drain line


Pete L.

Pete L. Job Checkin

Check blower and amperage check drains checked all ductwork checked all electrical connections check secondary drain check secondary pan check evaporator coil found bad thermostat replace thermostat with homeowners thermostat checked amperage on condenser fan motor and a compressor check capacitor and contactor check Freon levels found Freon level low homeowner knows there is a leak advised homeowner if Freon leaks out again that we need to do leak check on system and isolate leak


Joseph S.

Joseph S. Job Checkin

Customer will call back if interested in having me out to give a bid after talking with wife & mother.


Joe S.

Joe S. Job Checkin

Installed 4 Ton coil & charged system with R-22 Freon.


Alex T.

Alex T. Job Checkin

Pressures are low on the 15 Year old system and temperature splits are under performing. Recommended 3 options, replacement of Condenser/Coil, Replacement of Coil or charge with freon and see how long it will last.


Alex T.

Alex T. Job Checkin

ac repair: gas control valve is leaking by when off, leaking gas into attic space and furnace cabinet. Blower motor torque booster is out of range and causing stress on the blower. Gas valve and torque booster have been replaced, no leaks detected or smelled.


Matthew J.

Matthew J. Job Checkin

Maintenance: furnace is functioning properly at this time with a 40 degree heat rise at the unit witch is in range according to the data plate. Heat exchanger and blower assembly were in good condition. Custom had air scrubber and media cabinet for increased air quality. Cleared drain lines and assured float was functioning properly as well.


Joseph S.

Joseph S. Job Checkin

Called & left a vm.


Matthew J.

Matthew J. Job Checkin

Ac repair: water was occasionally dripping down return chase. System is a air handler which is negative pressure. Primary drain pan and p trap had some build up I in it which could be cause water to splash out of pan and down the chase at times due to the systems negative pressure. Blew out drain lines and poured drain solve to help break up any build up in the lines and primary drain pan. Also added another exhaust vent down the line from the p trap to help from sucking water back in due the negative pressure.


Matthew J.

Matthew J. Job Checkin

Installation: came out to install a surge protector on the out door unit. System is functioning properly at this time. Installing single component surge protectors on outdoor unit.


Matthew J.

Matthew J. Job Checkin

Ac repair: bad capacitor and tripped breaker. Looks as if surge blew the capacitor and tripped breaker due to the fact the capacitor was fine a month ago and is now mushroomed on top and had no microfarad readings . Customer wants to have a surge protector installed next week. Unit is currently up and running properly.