Pete L.

Pete L. Job Checkin

Check system out check Freon levels took temperature differential checked all ductwork checked all electrical connections


Matt P.

Matt P. Job Checkin

Compressor is over amping at 22amps, it is determined that the compressor has failed.


Pete L.

Pete L. Job Checkin

Found compressor not running check capacitor capacitor weak replace capacitor found system low on freon homeowner had another technician in here taken out Freon and putting freon in and replace TXV valve I recharge system and Freon leaks out quickly we need to do leaks search


Pete L.

Pete L. Job Checkin

Found fuse blown replace fuse and checked operations


Joseph S.

Joseph S. Job Checkin

System had a bad capacitor on outdoor unit that needed to be replaced, System had fluctuating cooling performances and after a deeper review might have a possible restriction in the line set which would require a a major repair. Informed Marie and asked her to review throughout summer for performance and if it is not cooling well the repair will be necessary to correct issue.


Alex T.

Alex T. Job Checkin

Home warranty: wire disconnected at heater, and tstat not set up for 2 stage heat.


Joseph S.

Joseph S. Job Checkin

Maintenance: performed heating maintenance. Heater is operating normally at this time. Achieving a 36 degree temperature rise at this time.


Alex T.

Alex T. Job Checkin

Home Warranty: thermostat is made for a heat pump system, system recently installed is straight AC only. Set thermostat to emergency heat and system is achieving 16 degree temperature rise.


Alex T.

Alex T. Job Checkin

AC repair: thermostat batteries were dead, no indication on the thermostat. Thermostat was frozen. Replace thermostat batteries system operated normally.


Matthew J.

Matthew J. Job Checkin

Ac repair: there was a break in the low voltage wire at the condenser. Replaced small section of wire that had the break in it. Unit is up and running with a 15 split. Also preformed tune up for the heating side of the system. Unit had a 34 degree rise in temperature. Heating elements and limit switches are functioning properly as well. Blower motor amp draws and capacitor were in range. Filters were recently changed and in good condition. Custom would like invoice emailed


Matthew J.

Matthew J. Job Checkin

Diagnostic: downstairs unit drain line was clogged and dripping some water into the emergency drain pan. Primary line ran under the sink. Recommended removing trap from under sink cleaning it out a blowing out the lines. Also notice that units do not have a condensate switch. Recommended installing those as well.


Matthew J.

Matthew J. Job Checkin

Tune up: customer just wanted to have condenser coils cleaned. Explained to him what was all included in a tune up but still just want the condensers cleaned. Removed the top of the condenser and deep cleaned coils with water hose. Took a look up in the attic and noticed there were no float switches. Recommend installing float switches to drain pans. Did not open up furnace or check over systems components or pressures.


Matthew J.

Matthew J. Job Checkin

Maintenance: both outdoor units line set needs to be insulated. The upstairs unit show no sign of issue capacitor and amp draws were in range. Down stairs unit fan motor and assembly seems to be off balance and wobbling. Motor potentially has loose barrings which will cause a wobble and the fan blade to bend overtime. Capacitor is out of range as well on the down stairs unit. There was no data plate info available for the downstairs unit. Indoor units are functioning properly at this time. Both units amp draws were in range and drain lines were cleared. Noticed there was no condensate switches on either of the units Recommendations: replacing the downstairs fan motor and blade along with the capacitor. Re insulating lines suction lines for both units condensers as well as install float switches for both units in the attic. Customer is interested in a quote for replacement. Duct fogging was also completed


Alex T.

Alex T. Job Checkin

Maintenance: system is operating normally at this time achieving a 16 degree temperature split. Will install float switch on next visit.


Matthew J.

Matthew J. Job Checkin

Ax repair: customer had a power surge and the ac unit did not come on after. Noticed that the fuse was blown and this was not the first time the incident has happened. Replaced fuse as well as installed a surge protector on the air handler to prevent any future surges causing damage to components in the air handler. Customer is on a payment to cover the expense of the service provided.