Scott S.

Scott S. Job Checkin

Installed inlet system. Collected check


Scott S.

Scott S. Job Checkin

Performed routine maintenance on two systems 2018 checked heat strips checked blower motor checked condenser motor checked capacitor checked contactor checked compressor cleaned both coil‘s checked temperature checked pressure units are working OK at this time


Scott S.

Scott S. Job Checkin


Scott S.

Scott S. Job Checkin

Run circuits for fans. Change devices


Scott S.

Scott S. Job Checkin

Performed routine maintenance on two Goodman systems checked heat strips checked blower motor checked condenser motor checked compressor checked contactor checked capacitor checked temperature checked pressure checked drains cleaned both coils One capacitor was bad and replaced units are working OK at this time


Scott S.

Scott S. Job Checkin

Customer having issues with dirty sock syndrome also has four UV bulbs that need to be replaced Robert is ordering UV bulbs and dirty sock spray customer asked for Friday morning to come back and do the work Both evaporator coil’s need to be treated forgot dirty sock and all four UV bulbs need to be replaced


Scott S.

Scott S. Job Checkin

Two service agreement clean and checks on a 9 year old split heat pump system and a 3 year old mini split heat pump system. Cleaned washable filters, installed new filters client provided. Washed and waxed outdoor units. Cleaned evaporator coils. Flushed out drain lines. Brushed out debris from electrical compartments. Tightened all electrical connections. Uv light is working well. Start booster is lowering cranking amps on the compressor. Amps on condenser fan motor are a little high.compressor at 200:megaohms. System refrigerant charges are good. Ductwork is clean. Systems are operating properly at this time, older system is starting to show signs of age and Ware.


Scott S.

Scott S. Job Checkin

Performed routine maintenance on 4yr old ruud system furnace straight ac Check burners checked flu checked safeties checked inducer draft check gas valve checked blower motor checked condenser motor checked compressor checked contactor checked capacitor unit is running good at this time also check the Mitsubishi mini split unit is running OK at this time


Scott S.

Scott S. Job Checkin

Check system found straight AC with nest thermostat wired as heat pump instructed customer to leave system in fan mode for several hours as system is iced up due to heat strips and compressor running at the same time wired nest up correctly unit is working at this time No charge for callback


Scott S.

Scott S. Job Checkin

Quoted job


Scott S.

Scott S. Job Checkin

Performed routine maintenance on two year old ruud wall hung system Check heat strips clean coil checked blower motor checked condenser motor checked compressor checked contactor checked capacitor checked pressure check temperature unit is working good at this time


Scott S.

Scott S. Job Checkin

Performed routine maintenance on two Lenox systems one is a two-year-old unit the other is one-year-old check heat strips clean coils checked blower motors checked condenser motors checked compressors checked contactor‘s checked capacitors checked temperature check pressure units are both running good at this time installed stay clean pan strip on downstairs unit


Scott S.

Scott S. Job Checkin

Preformed service call on 2005 Bryant system system has leak system is an r22 system client would like estement on replacing


Scott S.

Scott S. Job Checkin

2011 Goodman system- checked system amps checked blower motor and blower wheel checked evaporator coil and clean evaporator coil checked wiring checked fan motor checked compressor checked contactors and capacitors checked float switch checked heat strips checked condenser coil and clean condenser coil. Homeowner wanted to invest in new indoor and outdoor capacitors after being shown they were weak.


Scott S.

Scott S. Job Checkin

Checked system amps checked blower motor and blower wheel checked evaporator coil and clean evaporator coil checked wiring checked fan motor checked compressor checked contactors and capacitors checked float switch checked heat strips checked condenser coil and clean condenser coil. Homeowners wanted to invest in a stay clean strip. Also homeowners wanted to invest in a new capacitor after being shown the old one was weak. The capacitor was covered by 10/10/10 warranty.