3204 Fred Nash Blvd
Myrtle Beach, SC 29577
8432369060

Local Reviews
for longs, sc

Rated 4.9 out of 5 stars based on 42 customer reviews

Swift serviced provided


Response from Swift Services Heating & Cooling:

Thank You, please refer us to your Neighbors, friends, and family

  • Overall Experience
  • Quality
  • Price
  • Convenience

problem solved

it appears that there was an ongoing problem and it was corrected


Response from Swift Services Heating & Cooling:

Thank You, please refer us to your Neighbors, friends, and family

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great job


Response from Swift Services Heating & Cooling:

Thank you for sharing your recent HVAC service with us, we are glad to hear you received Excellent service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Robert was very professional and informative. Thank you for your help

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Very professional, very nice


Response from Swift Services Heating & Cooling:

Hi Steven, thank you for sharing your recent HVAC service with us, we are glad to hear you received excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and friendly


Response from Swift Services Heating & Cooling:

Thank You, please refer us to your Neighbors, friends, and family

  • Overall Experience
  • Quality
  • Price
  • Convenience

response

technician was great but the issues with just getting the scheduled appoitment from your company was bad .but all is forgiven since david was great technician and informed me of all services completed by him .so thanks for a pleasant experience


Response from Swift Services Heating & Cooling:

Hi Ken, would love an opportunity to discuss your recent experience and find out what we could do in the future to make your next visit a 5-star one!

  • Overall Experience
  • Quality
  • Price
  • Convenience

He knew his job. Kept me informed of everything he was doing.

Great service very clean


Response from Swift Services Heating & Cooling:

Hi Jo Ann, we know what a stressful time it is in the world right now, and we want to make sure our customer's HVAC unit is not adding to that stress. this is why we do our best to get to our customers as quickly as possible, so we can make your home comfortable again! Additionally, we are doing our part to prevent the spread by taking extra precautions to guarantee the safety of our customers and employees.

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

explained the system to better understand my situation


Response from Swift Services Heating & Cooling:

Thank You, please refer us to your Neighbors, friends, and family

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service


Response from Swift Services Heating & Cooling:

Thank You, please refer us to your Neighbors, friends, and family

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for longs, sc

David S.

David S. Job Checkin

Preformed prepaid maintenance on a Goodman split heat pump unit, model and serial number match in the system. Checked the filter and checked pressures and cleared drain line. Cleaned coils and added mildew destroyer to drain line for added drain line protection. Checked temperature split and checked air flow. Recommended and installed Blue Tube Kit for unit due to growth formation inside the air handler. This is for air quality. All systematic components are working properly at this time.


Corey W.

Corey W. Job Checkin

Performed clean & check. Delta T: -16°. Tested pan float switch, and made sure electrical connections were tight. No water or rust in secondary pan. Cleaned the evaporator and condenser coils. Cleared the primary condensate drain line. 45/5 dual run capacitor(44.3MFD-herm, 4.6MFD-fan). 121psig suction pressure(8°SH) which meets manufactures specifications. System is operating as it should.


Clay B.

Clay B. Job Checkin

Completed tune up. Found water puddling inside air handler and dripping into secondary pan. Wrong blower has been installed in a/h and airflow not correct. This has caused inaccurate refrigerant pressures and the TXV valve is not metering correctly. Only getting a 9 degree temperature split in home. Needs to have correct motor and TXV replaced.


Paul H.

Paul H. Job Checkin

Checked and cleaned coils, checked and cleaned drain line, added drain tablets for drain line clog prevention, checked filter, delta t was in line with factory recommendations. Pressures and capacitor were in line with factory recommendations. System is running as it should at this time.


Paul H.

Paul H. Job Checkin

Reattached the supply plenum to the air handler and coastal with mastic.


Donta S.

Donta S. Job Checkin

Screwed lense cover to studs in ceiling. Was not attached before.


Donta S.

Donta S. Job Checkin

Quote for whole house generator.


Robert P.

Robert P. Job Checkin

System never made noise that it was making that day but it’s cooler and the pressures are ok at this time.


Corey W.

Corey W. Job Checkin

Performed SSA t/u. Delta T: -13°. Tested pan float switch, and made sure electrical connections were tight. Cleaned the evaporator and condenser coils. Cleared the primary condensate drain line. Checked dual run capacitor(testing in range). Checked the refrigerant levels(meet manufactures specifications). System is operating as it should.


Corey W.

Corey W. Job Checkin

Performed 1st SSA t/u. Delta T: -15°. Tested pan float switch, and made sure electrical connections were tight. Replaced stay clean strip to treat drain line. Cleaned the Evaporator and Condenser coils. Cleared the primary condensate drain line. Tested dual run capacitor(testing within range). Checked the refrigerant levels(meet manufactures specifications). System is operating as it should.


Corey W.

Corey W. Job Checkin

Performed SSM t/u on a Bryant gas furnace/straight A/C. Delta T: -15°. Tested SS2, and made sure electrical connections were tight. Cleaned the Evaporator and Condenser coils. Cleared the primary condensate drain line. Checked the refrigerant levels(meet manufactures specifications) system is operating as it should.


Corey W.

Corey W. Job Checkin

Performed 1st SSA t/u. Delta T: -18°. Tested pan float switch, and made sure electrical connections were tight. Monitored bacterial growth. Cleaned the Evaporator and Condenser coils. Cleared the primary condensate drain line. Checked the refrigerant levels(meet manufactures specifications) checked the dual run capacitor(testing within range). System is operating as it should.


Chris B.

Chris B. Job Checkin

no answer called twice needs to reschedule


Ej F.

Ej F. Job Checkin

Service call-condenser not running. Found a failed capacitor. Replaced capacitor system came right on. Home is now cooling.


Robert P.

Robert P. Job Checkin

Found system not cooling good on the master bedroom zone found damper stuck on the guide rod from damper motor adjusted made corrections under install wty.