3204 Fred Nash Blvd
Myrtle Beach, SC 29577
8432369060

Local Reviews
for loris, sc

Rated 5.0 out of 5 stars based on 3 customer reviews

Great customer service.

fast service. very professional


Response from Swift Services Heating & Cooling:

Thank you, William and Nancy, we like to provide our customers with excellent service through hard work, explaining procedures, so the client understands the work being done and keeping a clean workspace!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great customer service.

Explained different options and emailed them quickly.


Response from Swift Services Heating & Cooling:

Thank you, Nancy, for sharing your recent 5-star HVAC experience with us!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Paul is very thorough and terrific in his job.


Response from Swift Services Heating & Cooling:

Hi Joe, we will be sure to share your kind words with Paul.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for loris, sc

Swift  S.

Swift S. Job Checkin

Install new 14 seer 2.5 ton Ruud split system


Clay B.

Clay B. Job Checkin

Completed paperwork


Paul H.

Paul H. Job Checkin

Replaced icomfort control board.


Robert P.

Robert P. Job Checkin

Control board failed will put a return for service to replace board.


Robert P.

Robert P. Job Checkin

Adjusted charge on system install callback.


Robert P.

Robert P. Job Checkin

Found thermostat has failed and adjusted his air flow to increase air movement. Covered by install wty


Swift  S.

Swift S. Job Checkin

14 seer 3 ton Ruud split system


Clay B.

Clay B. Job Checkin

Approved replacement for Friday


Clay B.

Clay B. Job Checkin

Email quote to replace three 3 ton split systems, three 7.5 ton split systems, all are 208/230 3ph.


Clay B.

Clay B. Job Checkin

Checked outdoor unit, severe hail damage to condenser coil. Tried to use fin comb on a couple areas, but coil is too flattened out to get into the fins. Also, condenser coil is coated with a weather guard coating, and untreated areas of the coil are now exposed. Condenser coil needs replaced, however, should consider replacing complete condenser due to not much difference in cost.


Paul H.

Paul H. Job Checkin

Dehumidifier was unplugged.


Robert P.

Robert P. Job Checkin

Recovered 4 lbs f r410a. Removed old evap coil. Brazed in new evap coil. Vacuumed below 500 microns charge system with six lbs of r410a. System up and running. Home owner replaced batteries in thermostat and replaced two filters. 1 yr labor and part on repair home owner wants tune up in October.


Robert P.

Robert P. Job Checkin

Found system low on charge found. Evap coil is leaking. Returning for repair.


Swift  S.

Swift S. Job Checkin

Checked system. Voltage/amps, airflow, pressures, all good. Cleared drain and cleaned coils. Installed pan float switch. Outdoor capacitor is weak at outdoor unit, 45/5 and reading 40/5. Customer declined capacitor at this time.


Paul H.

Paul H. Job Checkin

Completed tune up on 2 split systems and 1 mini split system. All working good. Verified drain line open and filters good.