Heating maintenance completed on 1yr old furnace; replaced filter provided by homeowner; all components operating properly within manufacturer specifications; no recommendations at this time.


Christopher  M.

Christopher M. Job Checkin

No Heat diagnostic on 15yr old 70k York LoNos Furnace; cleaned flame sensor, gas valve pressure fully open; no pressure, system fail no flame sensed; recommend repair or replacement; call to schedule; will discount repair or replacement by $89 if done within 30 days.


Ramon E.

Ramon E. Job Checkin

Thompson plumbing walked property and counted all the kitchen and sewer line clean outs to provide a accurate estimate for maintenance on the sewer lines. Thompson plumbing must go over job with manager to provide a accurate estimate for drain cleaning. Thompson plumbing estimates the job will take 2 to 3 full days of drain cleaning. Cars in parking garage would have to be all gone while we service sections of parking garage. Thompson plumbing took pictures of sewer lines and noticed there is several pipes that are in very bad condition Thompson plumbing is not responsible for any damages due to drain cleaning.


Ramon E.

Ramon E. Job Checkin

Thompson plumbing ran half inch cable down 2 inch clean out directly below unit nine. Cleared common kitchen line stack for unit nine and 10. Thompson plumbing pulled out large amounts of black grease buildup. Put back together clean out underneath unit nine inside parking garage. Ran water to test for proper drainage. Everything drains fine for now. Cleaned up work area and took pictures. Call the property manager to update. No warranty on drain cleaning due to major grease buildup. Per HOA they will mail a check for today’s service Emailed homeowners association invoice with payment link attached Spoke directly with homeowners association Pictures attached No warranty


Ramon E.

Ramon E. Job Checkin

Thompson plumbing contacted customer to inform that she might have to contact HOA in order for them to call us and schedule appointment to service common line drains.


Ty J.

Ty J. Job Checkin

Customer installed a new thermostat but the card board that separates the thermostat contacts was not removed. Removed card board and tested system. Heating now functions. Cleaned millivolt generator.


Ty J.

Ty J. Job Checkin

Replaced the blower motor module and tested the heating functions.


Ty J.

Ty J. Job Checkin

Faulty blower motor module.


Bryan R.

Bryan R. Job Checkin

Gave estimate for drain reroute


Mark R.

Mark R. Job Checkin

Estimate to include removal of existing equipment, old equipment hauled away and recycled, new 24x14 bar type filter grill, new 3 ton X series inverter air conditioning condenser, new 3 ton 96% efficient 2 stage variable speed upflow furnace, new 3 ton cased coil with txv metering device, run new lineset under home to condenser location, relocate supply duct to ceiling to allow room for evaporator coil, condenser to side of home, new condenser pad with earthquake straps, new 240volt electrical disconnect and wire whip, fuses to match manufacturing specs, double walled exhaust venting to proper connections, new Honeywell t6 pro programmable thermostat, re seal and insulate exposed refrigerant piping, refrigerant locking service caps, new refrigerant filter dryer, re plumb primary condensation drain line to proper connections with trap and tee, secondary condensation safety switch, adapt to existing supply plenum, return plenum modifications, re sealed and insulated, nitrogen pressure t


Ramon E.

Ramon E. Job Checkin

Upstairs shower tub leaks when in use. Thompson found shower neck was loose. Thompson plumbing added Teflon tape put back original shower neck. Ran water to test. No leaks found. Cleaned up work area. Collected payment. Payment cash money No warranty Spoke directly with homeowner No recommendation No need for follow up Pictures attached


Ty J.

Ty J. Job Checkin

Replaced blower motor and module. Tested the system and it is functioning.


Dylan K.

Dylan K. Job Checkin

Arrived for no cool. Found system low on refrigerant. Due to type of refrigerant and condition of unit it is recommended for replacement. Ac 11 years old. Furnace 19 years old.


Ignacio V.

Ignacio V. Job Checkin

Preformed a pressure test at the homes hose bib and got a reading of 50 psi. We could not recreate the whistling sound that the customer had told us about. Pressure regulator looks to be semi new.


Ty J.

Ty J. Job Checkin

Inspection of the system upon arrival showed the condensing unit running but the indoor unit fan was not. When disconnecting the communication wires to the fan motor I noticed one of the wires was not fully seated in the connector. Reseated the connector and tested the system. System functioned in all modes (heating, cooling and fan)