12-4-2025: measured sewer in preparation for lining from 6” pvc outside clean out(6’4”deep) to city main, also measured to line from 4” pvc stack clean out in basement starting in 4” pvc near 3” stack and ending in 6” pvc near outside clean out, reinstate outside clean out, will NOT reinstate 4” clean out in basement. Need to descale 4” cast and vac loose scale prior to lining. 12-9-2025: lined sewer from 6” pvc clean out in front yard 49’ downstream to city main starting liner in 6” pvc near clean out and ending liner just before city main, also lined from 4” pvc stack clean out in basement 28’ downstream to 6” pvc outside clean out starting liner 18’ downstream in 4” pvc near 3” stack tie in and ending in 6” pvc just downstream of clean out, reinstated 6” pvc outside clean out, did NOT reinstate old 4” floor clean out/ possible old stack in basement.