1762 S Dixie Hwy #2
Crete, IL 60417
708-758-5070

Our Top Cities


Local Reviews
for crown point, in

Rated 5.0 out of 5 stars based on 3 customer reviews

Great crew professional

Awesome experience


Response from Trenchless Innovations Inc.:

Thank you for sharing your experience with our team, Alan! We are happy that our sewer lining process could solve your sewer problems. We are grateful for your business and hope you enjoy the benefits of a free flowing sewer for years to come. Thank you again!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great experience

After my first plumber said I should remove my sewer pipes to the city sewer I turned to Trenchless Innovations who suggested lining my pipes to the city sewer instead of replacing them. Kevin Wall and Jim D showed up at the promised time, and quickly started the job. The 3rd technician was John R one of the companies owners I was impressed. They finished the job in a timely manner, and the before and after videos seem to indicate a job well done. Now the roots can’t get to the pipes, and I have a 50 year warranty on the lining. My thanks Kevin, John and Jim. Job well done.


Response from Trenchless Innovations Inc.:

Ed, thank you for taking the time to share your experience with us! We are very happy to hear you had a pleasant experience from start to finish and we are glad you would eliminate your tree root problem for you. We hope you enjoy the benefits of your sewer lining for many years. Thank you for choosing Trenchless Innovations for your sewer lining project. Give us a call anytime if you have any further questions whatsoever. Thank you again!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good Experience

Showing the video of the damage and after the repair was everything to me. Nothing boosts confidence of a decision more than knowledge.


Response from Trenchless Innovations Inc.:

Thank you so much for this great 5-star review.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for crown point, in

Kevin W.

Kevin W. Job Checkin

Sand is entering certain areas of the ducts due to water entering the ducts and washing sand in. Sprayed RS-100 over areas where sand is entering the air ducts.


Bob S.

Bob S. Job Checkin

Televised duct under slab floor. Ducts are concrete with metal joints that are rusted and allowing water to enter the system. There is a sump pit but it is not deep enough, there is no coring into the foundation and the discharge appears to be blocked. Suggest installing a deeper sump pit and coring ito foundation wall to alleviate pressure and lower false water table.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are plastic coated galvanized metal ducts that are very rusted. Suggest a sump pit and pump to control the water then spin cast and spray line ducts to rehab them.


Jim D.

Jim D. Job Checkin

Blocked off both registers with foam and hydraulic cement in master bedroom. Cemented over both registers. Blocked off the right side leading to master bedroom in the bathroom and blocked off left side of bedroom on front left side of basement. Resprayed both registers with duct armor.


Jim D.

Jim D. Job Checkin

I completed the lining of a 6-inch sewer line, starting from an exterior cleanout and extending approximately 60 feet downstream. This process involved the installation of a cured-in-place pipe (CIPP) liner, which was meticulously measured and inserted to end just before the connection to the city main. This technique ensures a seamless and durable reinforcement of the existing pipeline, enhancing its longevity and functionality.


Jim D.

Jim D. Job Checkin

Cleaned and applied first application of spray lining except for an area approximately 10' long that had water present. 2 patches will be installed next visit for an additional $500.


Jim D.

Jim D. Job Checkin

• Broke up the concrete floor and excavated the area in the garage near the furnace. •Dug under furnace to alleviate pressure under foundation and installed 4” perforated corrugated pipe. • Installed a 20” wide by 42” deep perforated sump pit in the excavated area and backfilled with ¾” stone with sealed cover. • Installed a sump pump in new pit and ran discharge line through garage and exited through the side wall of garage and out the front of house. • Backfilled excavated area with stone and re-cemented concrete floor. • Removd all debris from the worksite.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are Pvc ducts with metal fittings. There was standing water in the system in the larger ducts. Suggest possible installation of a pit and pump if downspouts and regrading does not solve water issue. After that the ducts should be spray lined with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

RTelevised ducts under slab floor. Ducts are PVC and had some slight water in ducts and also show signs of mold. There is work to be done for drainage on right side of house to control the water issue. After that the ducts should be spray lined with Duct Armor duct lining material.


 .

. Job Checkin

Under slab ductwork video inspection. After inspecting ducts saw that they are made of galvanized steel and starting to rust in several locations. Spin cast mortaring is recommended followed up by Duct Armor for trenchless duct lining repair.


Jim D.

Jim D. Job Checkin

Sewer line repair service call. Installed 5' spot repair from overhead clean covering over Cracked pipe ending in 6' pipe.


Bob S.

Bob S. Job Checkin

Slab leak detection service call. Televised ducts under slab floor on lower level of house. Ducts are galvanized and are extremely rusted. Suggest spin cast mortaring then spray lining with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Sewer video inspection service call. Televised sewer from overhead clean out. PVC pips is cracked just outside foundation wall. Will provide a proposal for installing a patch liner. Basement has 10ft ceilings


Bob S.

Bob S. Job Checkin

Under slab leak detection service call. Televised ducts under slab floor. Ducts are concrete ducts with metal fittings that are showing heavy signs of rust and deterioration. Provide quote for spin cast mortaring metal fittings the spray lining entire system.


Kevin W.

Kevin W. Job Checkin

2-17-2023: rodded sewer from outside clean out heavy roots at 4” clay cross connection for drain tile just upstream of 6” pvc clean out in front landscape bed, also rodded downstream to clear roots at 6” pvc-clay connection. Tvd to stack in basement also to city main line was clear, used P&T camera to verify cross connection for drain tile. DID NOT install patch at cast to clay connection where heavy roots were in line because it would cover over connection for drain tile. No sump pump or pit in basement has gravity sewer so drain tile leads to sewer at cross connection. Recommended preventative rodding to be done left Reid card and info with customer for future rodding.