Job Checkin

PERFORM INSPECTION ON 1 ROOFTOP PACKAGE HEAT PUMP SYSTEM. DIAGNOSIS: SYSTEM RUNNING FINE IN HEATING AND COOLING. VERIFIED SEQUENCE OF OPPERATION. TIGHTEN ELECTRICAL CONNECTIONS. TESTED FREON LEVELS. AMP DRAWS AND RUN CAPACITOR. UNIT IS SHOWING NORMAL WEAR DUE TO AGE. NOTE: INDOOR FILTER WAS RECENTLY CHANGED. NOTE: THE ELECTRICAL SEAL TIGHT WHIP HAS SEPERATED CAUSING EXPOSED ELECTRICAL WIRES. WEATHER MASTERS RECOMMENDS REPLACING THE ELECTRICAL WHIP. THE OUTDOOR CONDENSER COIL HAS HAIL DAMAGE AND MAY CAUSE ISSUES WITH THE SYSTEM. WEATHER MASTERS RECOMMENDS HAVING THE COIL REPLACED TO PPREVENT ISSUES WITH THE SYSTEM OVER HEATING IN THE SUMMER OR ICING UP IN THE WINTER. WEATHER MASTERS WILL QUOTE THESE REPAIRS.