155 E Broadway Rd.
Mesa, AZ 85210
480-832-9659

Local Reviews
for scottsdale, az

Rated 5.0 out of 5 stars based on 6 customer reviews

Efficient, informative, great price, very pleased.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and knowledgeable service technician

Very comprehensive testing of furnaces

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always great!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

very efficient and friendly

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Chris is excellent. Very good company

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for scottsdale, az

Jason G.

Jason G. Job Checkin

AC unit is not working at all.


Chris R.

Chris R. Job Checkin

REPLACE INDOOR BLOWER MOTOR WITH AFTER MARKET /THEY DONT MAKE THE OEM MOTOR ANYMORE PULL AND CLEAN RUSTED BLOWER WHEEL DURING MOTOR REPLACEMENT /THEY DONT MAKE THIS WHEEL ANYMORE CHEMICALLY CLEAN EVAPORATOR COIL IN PLACE WEATHER MASTERS CAN NOT WARRANTY THE OVERALL OPERATION AND EFFICIENCY OF THE UNIT DUE TO THE AGE AND CONDITION 5/15/19 WO#17120 REPLACED 1/5 HP BLOWER MOTOR WITH AFTER MARKET MOTOR/THEY DO NOT MAKE THE MOTOR ANYMORE CLEANED DAMAGED RUSTED BLOWER WHEEL /THEY DONT MAKE WHEEL ANYMORE HAD TO FABRICATE A NEW BRACKET BECAUSE THE OLD BRACKET IS PART OF THE MOTOR WEATHER MASTERS CAN NOT BE RESPONSIBLE FOR THE OPERATION OR LIFE OF THE REPAIR CHEMICALLY CLEANED EVAPORATOR COIL UNIT IS COOLING AT THIS TIME


Robert T.

Robert T. Job Checkin

REMOVE AND HAUL AWAY EXISTING 4 TON GAS PACK INSTALL NEW 14 SEER DAY AND NIGHT 4 TON GAS PACK 5000 T-STAT SHEET METAL TRANSITION RED WOOD SLEEPERS 1 YR LABOR 10 YR PARTS AND COMPRESSOR WEATHER MASTERS IS NOT RESPONSIBLE FOR DRYWALL /PAINT REPAIRS


Chris R.

Chris R. Job Checkin

PROBLEM NO COOL CARRIER SERIAL N508848 #17149 DIAGNOSIS 5 MFD RUN CAPACITOR HAS FAILED /MOTOR HAS TAKEN PERMANENT INTERNAL DAMAGE /MAY FAIL SOON BURNED DAMAGED WIRES UNIT OVERALL IS SHOWING HEAVY HEAVY WEAR DUE TO AGE AND USAGE /RECOMMEND REPLACING SOON /WE WILL QUOTE UPON REQUEST REPLACED 5MFD RUN CAPACITOR REPAIRED BURNED DAMAGE


Chris R.

Chris R. Job Checkin

PROBLEM PMP VISIT@3 LENNOX OFFICE 12HPB24-10P 5805B48448 MASTER 13ACC-060-230-01 5805C27151 KITCHEN 13ACC-060-230-01 5805C27152 DIAGNOSIS ALL 3 UNIT ARE SHOWING HEAVY WEAR DUE TO AGE AND USAGE RUN CAPACITORS FOR THE INDOOR BLOWER MOTOR ON THE OFFICE A/H IS WEAK /RECOMMEND REPLACING THE CAP TO HELP EXTEND THE LIFE OF THE MOTOR {7.5} ALL OTHER RUN CAPACITORS ARE SHOWING WEAR BUT STILL WITHIN MANUFACTURE SPECIFICATIONS AT THIS /THEY MAY NEED TO BE REPLACED AT NEXT VISIT MOTOR AMPS FOR ALL 3 UNITS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME ALL THREE UNITS ARE COOLING WITHPROPER TEMPERATURE SPLITS ACROSS EVAPORATOR COILS REPAIRS REPLACED 7.5 RUN CAPACITOR FOR THE INDOOR BLOWER MOTOR ON THE OFFICE UNIT TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COILS FLUSHED DRAINS


Stuart M.

Stuart M. Job Checkin

Weather Masters successfully completed a 37 point inspection on 2 units - weather Masters tightened all electrical fittings - checked all Freon levels and pressures - checked amperage of indoor and outdoor motor. Working at intended anprage -Ensured run capacitor is running with proper MFD's and is not leaking - subcool is 13 and 14 -examined indoor and outdoor coil. Outdoor coils werecleaned with water -temperature split is normal -thermostat is working as should -customer regularly changes filter so it is clean -customer says unit is working well At this time, the systems are running normally.


Chris R.

Chris R. Job Checkin

PROBLEM 37 PT INSPECTION GOETTL GP4854-075C 01232255 UNIT IS SHOWING HEAVY WEAR DUE TO AGE AND USAGE TEMPERATURE SPLIT ACROSS THE EVAPORATOR COIL IS LOW EVAPORATOR COIL IS ICING /PREFORMED LEAK SEARCH AND DETECTED A LEAK AT THE INDOOR AND OUTDOOR COILS CAN'T PIN POINT LEAK AT THIS TIME /WE WOULD NEED TO ADD DIE TO PIN POINT THE LEAK DUE TO THE AGE OF THIS UNIT WE RECOMMEND REPLACING IT UNIT MAY NOT COOL EFFICIENTLY THIS SUMMER CUSTOMER WANT TO HOLD OFF AT THIS TIME ON REPLACING THE UNIT TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL DRAIN PAN IS FULL OF DEBRIS /THIS MAY CAUSE DRAINING ISSUES WE WILL PROVIDE A QUOTE APPON REQUEST


Stuart M.

Stuart M. Job Checkin

PROBLEM: CONDENSATE LINE LEAKING INTO RESIDENCE DIAGNOSIS: CONDENSATE LINE CLOGGED WAS CLEARED OUT USING NITROGEN AND FLUSHED. CONDENSATE LINE DRAINING NORMALLY AFTER SERVICE


Stuart M.

Stuart M. Job Checkin

PERFORM FILTER CHANGE ON 7 SYSTEMS. PERFORM INSPECTIONS ON 7 UNITS. DIAGNOSIS: UNIT 20- REDLINE IS NOT USING THIS SYSTEM DUE TO NO THERMOSTAT CONNECTED. CONDENSER FAN MOTOR OVER AMPING , RECOMMEND REPLACMENT. MARS ECM UNIT 18- SYSTEM WAS NOT COOLING DUE TO BLOWN FUSES. SYSTEM IS TURNED OFF TO PREVENT COMPRESSOR FAILURE TILL SYSTEM CAN BE REPAIRED. CONDENSER FAN MOTOR OVER AMPING. SYSTEM HAD BLOWN 45 AMP FUSES. CONDENSATE DRAIN LINE CRACKED. NEEDS REPLACED. RECOMMEND REPLACING CONDENSER FAN MOTOR WITH MARS ECM. RECOMMEND NEW 60MFD COMPRESSOR CAPACITOR AND KS1 HARD START COMPRESSOR KIT. RECOMMEND NEW 15MFD CAPACITOR FOR INDOOR BLOWER MOTOR. UNIT 16- SYSTEM RUNNING FINE IN COOLING JUST RECOMMEND HAVING REPAIRS DONE CONDENSER FAN MOTOR OVER AMPING . RECOMMEND NEW CONDENSER FAN MOTOR. MARS ECM . RECOMMEND NEW 60MFD CAPACITOR FOR COMPRESSOR. RECOMMEND NEW 15MFD CAPACITOR FOR INDOOR BLOWER. UNIT 19- SPLIT SYSTEM - UNIT RUNNING AND COOLING FINE. RECOMMED 5MFD CAPACITOR FOR O


Stuart M.

Stuart M. Job Checkin

PERFORMED 37 POINT INSPECTION ON TWO SPLIT AC ELECTRIC HEAT UNITS CHECKED AMP DRAWS OF MOTORS TESTED RUN CAPACITORS TO BE WITHIN MANUFACTURERS RATING VERIFIED TEMP SPLIT ACROSS COILS TIGHTENED ELECTRICAL CONNECTIONS INSPECTED CONDITION OF UNIT DOWNSTAIRS UNIT HAS WEAK DUAL CAPACITOR TESTING FAR BELOW THE MANUFACTURER'S RANGE. WEATHER MASTERS RECOMMENDS REPLACEMENT OF THIS COMPONENT AS ITS CONTINUED USE WHILE BEING WEAK MAY CAUSE THE MOTORS IT IS ATTACHED TO SUFFER PERMANENT INTERNAL DAMAGE. BOTH UNITS RUNNING IN COOLING AT TIME OF INSPECTION


Chris R.

Chris R. Job Checkin

PROBLEM PMP VISIT 1 UNIT DAY AND NIGHT C4A48GKD200 E100802098 DIAGNOSIS 45/7.5 IS SHOWING WEAR BUT STILL WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME /MAY NEED TO BE REPLACED AT NEXT VISIT ALL MOTOR AMPS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME CHARGE IS RUNNING 10 DEGREES OF SUB COOLING /UNIT CALLS FOR 12 PLUS OR MINUS 3 DEGREES /MAY NEED TO ADD AT NEXT VISIT UNIT IS COOLING WITH NO ISSUES AT THIS TIME TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL FLUSHED DRAIN


Chris R.

Chris R. Job Checkin

PROBLEM NO HEAT DIAGNOSIS INDOOR BLOWER MOTOR MOTOR IS INTERNALLY DAMAGED CAUSING THE UNIT TO CYCLE OFF ON HIGH HEAD WHEN THE MOTOR STOPS WORKING DUE TO THE AGE AND CONDITION WEATHER MASTERS RECOMMENDS REPLACING THE SYSTEM


Stuart M.

Stuart M. Job Checkin

PERFORMED 37 POINT INSPECTION ON TWO PACKAGE HEAT PUMP UNITS CHECKED AMP DRAWS OF MOTORS TESTED RUN CAPACITORS TO BE WITHIN MANUFACTURERS RATING VERIFIED TEMP SPLITS ACROSS COILS TIGHTENED ELECTRICAL CONNECTIONS INSPECTED CONDITION OF UNITS BOTH UNITS RUNNING NORMALLY IN COOLING AT TIME OF INSPECTION. WEATHER MASTERS RECOMMENDS FOLLOW UP INSPECTION IN FALL FOR HEATING SIDE OF SYSTEM.


Chris R.

Chris R. Job Checkin

PROBLEM 37PT INSPECTION TRANE TTN048C100A3 P123RCJFF DIAGNOSIS 7.5 MFD RUN CAPACITOR FOR THE CONDENSER FAN MOTOR IS WEAK /THIS WILL ALLOW INTERNAL DAMAGE TO THE MOTOR /RECOMMEND REPLACING THE CAP THE UNIT IS SHOWING HEAVY WEAR DUE TO AGE AND USAGE /WE DON'T RECOMMEND ANY COSTLY REPAIRS CHARGE LOOKS OK AT THIS TIME BUT DUE TO THE LOW AMBIENT TEMPERATURES TODAY WE CAN NOT VERIFY POSSIBLE ISSUES THAT MAY SHOW WHEN TEMPERATURES RISE REPAIRS REPLACED 7.5 RUN CAPACITOR FOR THE CONDENSER FAN MOTOR TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL VERIFIED SEQUENCE OF OPERATION IN THE COOLING MODE AND THE UNIT IS COOLING AT THIS TIME


Keith H.

Keith H. Job Checkin

PROBLEM: UNIT HAS A FAILED COMPRESSOR. WANTS ESTIMATE ON NEW SYSTEM. COMPRESSOR HAS BLOWN PIN.