Chris has a great attention to detail and is always willing to help us with our Energy Star Program
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Very responsive and gets the job done!
Overall Experience
Quality
Price
Convenience
Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.
Overall Experience
Quality
Price
Convenience
Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.
Overall Experience
Quality
Price
Convenience
I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs
Overall Experience
Quality
Price
Convenience
Chris takes pride in his works and cares about things getting done properly!
Overall Experience
Quality
Price
Convenience
Always on top of his game and knows everything that’s is happening in all his communities.
Overall Experience
Quality
Price
Convenience
Great service and great price!
Overall Experience
Quality
Price
Convenience
Great company. Always feel like they are looking out for me, from the time I call and make my bi-yearly appointments to the time the maintenance is complete and they walk out the door....top performance, top customer service. Thank you.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Seth provided excellent service as well as a descriptive report of all work done. He also provided some good tips to keep that we could do to keep things in proper working order. Thanks.
Overall Experience
Quality
Price
Convenience
Very positive experience. Seth answered all questions and concerns we had.
Overall Experience
Quality
Price
Convenience
THE MAN YOU SENT WAS VERY NICE AND DID A GREAT JOB. I FEEL VERY GOOD THAT I WILL NOT HAVEANY PROBLEMS THISWINTER.
Overall Experience
Quality
Price
Convenience
Gas heating preventative maintenance performed Check filter - 20x25x4 new today truck stock 1 on site Clean flame sensor - minor oxidation Inspect burners - clean no concerns Ohm test igniter: 53.1 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.25 Check amp draw on inducer motor:0.42 Check delta T - 55° Furnace is in optimal running conditions
Heat pump preventative maintenance performed Turn heat on at thermostat Check filter: 16x20x1 new today Inspect heating elements and wiring: no concerns Blower motor cap: n/a ECM Temp rise at — 56° Force defrost on outdoor unit reversing valve is operational Air handler and heat pump in optimal running conditions
Upon arrival inspected system and found no major concerns. Listened for noise once in attic and couldn’t recreate noise they were getting. It is only when the furnace is running it was rattling was the information I was given, couldn’t get any noises from unit. Moved a large rodent trap to get to furnace, suspect the rodent trap was rattling because it engaged as soon as I bumped it. Informed homeowner to call us back if noise continues but cannot recreate noise at this time.
Upon arrival inspected system and found inducer motor was seized and not operating. Quote replacement inducer motor and test run system, furnace blower not cycling after heat up cycle. Blower getting power but will not come on. Capacitor 10mfd @ 10mfd motor bad and needs replaced. Will have to return tomorrow to replace furnace blower motor. Remove and replace blower motor test run heat. Clean blower wheel and housing of dust buildup due to electronic air filter. No concerns post repair
Gas heating preventative maintenance performed Check filter - 16x25x1 clean Clean flame sensor Inspect burners - no concerns Ohm test igniter: 54.6 Inspect wiring for loose connections and/or hot spots - no concerns Check humidifier pad: n/a Inspect exhaust flu - 80% no concerns Set thermostat for heat Check amp draw on blower motor: 3.2 Check amp draw on inducer motor:0.6 Check delta T - 49° Furnace is in optimal running conditions
Remove and replace Goodman single stage gas valve due to unit not staying on. With power continuing to valve
Preventative maintenence inspection on Carrier high efficiency furnace. 20x25x4 air filter is new today. Clean flame sensor and check ignitor ohms. Flush condensation trap and drain lines. Run test unit in heating mode. Initial startup shows furnace operating with 3.8inwc of gas supply. This is at the top of the range and can cause short-cycling. Adjusted gas pressure to 3.0inwc at the low end of the range. This will prevent short cycling and allow the furnace to run longer and more evenly heat the house. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.
Gas heating preventative maintenance performed Check filter - 16x25x1 clean Clean flame sensor Inspect burners - clean no concerns Ohm test igniter: 49.2 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: clean from spring Inspect exhaust flu - no concerns 2” pvc Set thermostat for heat Check amp draw on blower motor: 1.0 Check amp draw on inducer motor:2.34 Check delta T - 54° Furnace is in optimal running conditions
Gas heating preventative maintenance performed Check filter - 20x25x1 new today Clean flame sensor Inspect burners - no concerns Ohm test igniter: 64.2 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.91 Check amp draw on inducer motor:0.62 Check delta T - 52° Heat pump operational and defrost functioning Furnace is in optimal running conditions
Remove faulty, pressure switch, and replaced with factory warranty part
Gas heating preventative maintenance performed Check filter - 20x25x1 Clean flame sensor Inspect burners - no concerns Ohm test igniter: 48.3 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - 2” pvc Set thermostat for heat Check amp draw on blower motor: 3.21 Check amp draw on inducer motor:0.38 Check delta T - 59° Furnace is in optimal running conditions
Preventative maintenence inspection on Comfortmaker furnace. 16x25x4 air filter in decent condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Humidifier damper is open, pad in good condition. Test run system in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. 4" galvanized B-vent in good condition and no sign of leaks. 0PPM CO detected during testing. Humidifier tested during heating operation. System is operating properly, efficiently and ready for Winter.
SOLD: 12/12/2025 1:44:19 PM - Option 3 Install New Daikin HVAC System Two Stage Variable Speed Furnace: Model #: DR80TC0603BN Serial #: 2509017663 60,000 BTU's - 80% AFUE High Efficiency, Side Discharge Air Conditioner: Model #: DC6VSS3010A Serial #: 2506183096 2.5 Ton - 17.2 SEER2 Indoor Coil: Model #: CAPEA3022B3 Serial #: 2502177225 Daikin One Touch Thermostat: Model# DTST-TOU-A Serial #: EA2503602130 Installation: * Reconnect to existing electric * Transition to existing supply and return ductwork * Start up and commission new system * Aprilaire 1210 (20x25) Media Air Cleaner Warranty: 12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed) 20 Year Daikin manufacturers Exchanger Warranty (Annual maintenance must be performed)
System was satisfying, desired temperature upon arrival. Inspected system and found no errors present. Homeowner informed me that furnace was back in a code one when he had to reset it. Informed homeowner that we will have to order the P1 pressure switch. To resolve issue due to a failed switch. Inspected drain and everything was clear and inducer motor was not pulling high amps. It was staying at 2.4 operational. Rated 2.7 Fla. unable to quote tonight due to being passed Goodman hours.
Basement East system is frozen solid. Turn fan on and will return for diagnosis once unit has thawed out.