725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for delaware, oh

Rated 4.9 out of 5 stars based on 27 customer reviews

Attention to detail

Chris has a great attention to detail and is always willing to help us with our Energy Star Program

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Quality personnel

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service Professional employees!

Very responsive and gets the job done!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great communication

Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and quick response!

Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.

  • Overall Experience
  • Quality
  • Price
  • Convenience

A professional in your own neighborhood

I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs

  • Overall Experience
  • Quality
  • Price
  • Convenience

Takes Pride

Chris takes pride in his works and cares about things getting done properly!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Always on top of his game and knows everything that’s is happening in all his communities.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, arrived on time and the price was great

Great service and great price!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, as always

Great company. Always feel like they are looking out for me, from the time I call and make my bi-yearly appointments to the time the maintenance is complete and they walk out the door....top performance, top customer service. Thank you.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Had service performed

Hi quality and knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Technician is competent and keeps to schedules.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Courteous and knowledgeable technician

Seth provided excellent service as well as a descriptive report of all work done. He also provided some good tips to keep that we could do to keep things in proper working order. Thanks.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always great, professional service

Very positive experience. Seth answered all questions and concerns we had.

  • Overall Experience
  • Quality
  • Price
  • Convenience

very happy with the service

THE MAN YOU SENT WAS VERY NICE AND DID A GREAT JOB. I FEEL VERY GOOD THAT I WILL NOT HAVEANY PROBLEMS THISWINTER.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for delaware, oh

Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x1 Clean flame sensor Inspect burners - no concerns Ohm test igniter: 48.3 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - 2” pvc Set thermostat for heat Check amp draw on blower motor: 3.21 Check amp draw on inducer motor:0.38 Check delta T - 59° Furnace is in optimal running conditions


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Comfortmaker furnace. 16x25x4 air filter in decent condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Humidifier damper is open, pad in good condition. Test run system in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. 4" galvanized B-vent in good condition and no sign of leaks. 0PPM CO detected during testing. Humidifier tested during heating operation. System is operating properly, efficiently and ready for Winter.


Jason D.

Jason D. Job Checkin

SOLD: 12/12/2025 1:44:19 PM - Option 3 Install New Daikin HVAC System Two Stage Variable Speed Furnace: Model #: DR80TC0603BN Serial #: 2509017663 60,000 BTU's - 80% AFUE High Efficiency, Side Discharge Air Conditioner: Model #: DC6VSS3010A Serial #: 2506183096 2.5 Ton - 17.2 SEER2 Indoor Coil: Model #: CAPEA3022B3 Serial #: 2502177225 Daikin One Touch Thermostat: Model# DTST-TOU-A Serial #: EA2503602130 Installation: * Reconnect to existing electric * Transition to existing supply and return ductwork * Start up and commission new system * Aprilaire 1210 (20x25) Media Air Cleaner Warranty: 12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed) 20 Year Daikin manufacturers Exchanger Warranty (Annual maintenance must be performed)


SOLD: 12/12/2025 1:44:19 PM - Option 3

Install New Daikin HVAC System
Two Stage Variable Speed Furnace:
Model #: DR80TC0603BN 
Serial #: 2509017663
60,000 BTU's - 80% AFUE
High Efficiency, Side Discharge Air Conditioner:
Model #: DC6VSS3010A
Serial #: 2506183096
2.5 Ton - 17.2 SEER2
Indoor Coil:
Model #: CAPEA3022B3
Serial #: 2502177225
Daikin One Touch Thermostat: 
Model# DTST-TOU-A
Serial #: EA2503602130
 
Installation:
* Reconnect to existing electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* Aprilaire 1210 (20x25) Media Air Cleaner
 
Warranty:
12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
20 Year Daikin manufacturers Exchanger Warranty (Annual maintenance must be performed)

SOLD: 12/12/2025 1:44:19 PM - Option 3

Install New Daikin HVAC System
Two Stage Variable Speed Furnace:
Model #: DR80TC0603BN 
Serial #: 2509017663
60,000 BTU's - 80% AFUE
High Efficiency, Side Discharge Air Conditioner:
Model #: DC6VSS3010A
Serial #: 2506183096
2.5 Ton - 17.2 SEER2
Indoor Coil:
Model #: CAPEA3022B3
Serial #: 2502177225
Daikin One Touch Thermostat: 
Model# DTST-TOU-A
Serial #: EA2503602130
 
Installation:
* Reconnect to existing electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* Aprilaire 1210 (20x25) Media Air Cleaner
 
Warranty:
12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
20 Year Daikin manufacturers Exchanger Warranty (Annual maintenance must be performed)

Graham M.

Graham M. Job Checkin

System was satisfying, desired temperature upon arrival. Inspected system and found no errors present. Homeowner informed me that furnace was back in a code one when he had to reset it. Informed homeowner that we will have to order the P1 pressure switch. To resolve issue due to a failed switch. Inspected drain and everything was clear and inducer motor was not pulling high amps. It was staying at 2.4 operational. Rated 2.7 Fla. unable to quote tonight due to being passed Goodman hours.

System was satisfying, desired temperature upon arrival. Inspected system and found no errors present. Homeowner informed me that furnace was back in a code one when he had to reset it. Informed homeowner that we will have to order the P1 pressure switch. To resolve issue due to a failed switch. Inspected drain and everything was clear and inducer motor was not pulling high amps. It was staying at 2.4 operational. Rated 2.7 Fla. unable to quote tonight due to being passed Goodman hours.

Brandon P.

Brandon P. Job Checkin

Basement East system is frozen solid. Turn fan on and will return for diagnosis once unit has thawed out.


Brandon P.

Brandon P. Job Checkin

Replacement warranty. Upon arrival, thermostat was in off mode. Inspected furnace for any obvious issues and found d that the furnace control board was not being powered. Removed door and pushed in door switch to check for power. With door switch pushed in by hand, the system came on. Put bottom door back on and noticed that the door was not pushing the door switch in all of the way as the door switch was hanging lower than it should be. Adjusted door switch for proper height and put door back on. With door on, system now has power. Turned thermostat to heating to check for any other issues. None found or suspected. Bob mentioned he would like a quote to install a ductless mini split in the garage. Photos on file of furnace for humidifier install, aswell as interior and exterior photos for mini split install.

Replacement warranty.
Upon arrival, thermostat was in off mode. Inspected furnace for any obvious issues and found d that the furnace control board was not being powered. Removed door and pushed in door switch to check for power. With door switch pushed in by hand, the system came on. Put bottom door back on and noticed that the door was not pushing the door switch in all of the way as the door switch was hanging lower than it should be. Adjusted door switch for proper height and put door back on. With door on, system now has power. Turned thermostat to heating to check for any other issues. None found or suspected.

Bob mentioned he would like a quote to install a ductless mini split in the garage. Photos on file of furnace for humidifier install, aswell as interior and exterior photos for mini split install. Replacement warranty.
Upon arrival, thermostat was in off mode. Inspected furnace for any obvious issues and found d that the furnace control board was not being powered. Removed door and pushed in door switch to check for power. With door switch pushed in by hand, the system came on. Put bottom door back on and noticed that the door was not pushing the door switch in all of the way as the door switch was hanging lower than it should be. Adjusted door switch for proper height and put door back on. With door on, system now has power. Turned thermostat to heating to check for any other issues. None found or suspected.

Bob mentioned he would like a quote to install a ductless mini split in the garage. Photos on file of furnace for humidifier install, aswell as interior and exterior photos for mini split install.

Graham M.

Graham M. Job Checkin

Cycle system and found intermittent blower speed operation. Repaired blower speed electrical connections and blower is operating correct at this time. Returned system to normal operation.


Brandon P.

Brandon P. Job Checkin

Upon arrival, system was off. Test ran operation through jumper wire on control board. Tested gas pressure and temperature rise as the mentioned 4 flash code indicates an airflow issue and/or overheating. Gas pressure on initial startup and at 3.9inwc when the system specifications are 3.2-3.8inwc. Set gas pressure to 3.2inwc. System was still on the higher end of the temperature rise range of 40-70F at 65F. After some further testing, it was found that the bypass humidifier does not have an airflow damper installed, nor the inner bracket with a humidifier pad. This is allowing an excessive amount of hot supply air directly back into the system artificially raising supply temp and continues to cause it to trip on limit switch even when running within temperature rise specs. Used tape to seal off humidifier pipe to block airflow, and bumped blower speed to Med-Hi from Med to get the temperature rise more towards the middle of the temperature rise. With all current settings, system is

Upon arrival, system was off. Test ran operation through jumper wire on control board. Tested gas pressure and temperature rise as the mentioned 4 flash code indicates an airflow issue and/or overheating. Gas pressure on initial startup and at 3.9inwc when the system specifications are 3.2-3.8inwc. Set gas pressure to 3.2inwc. System was still on the  higher end of the temperature rise range of 40-70F at 65F. After some further testing, it was found that the bypass humidifier does not have an airflow damper installed, nor the inner bracket with a humidifier pad. This is allowing an excessive amount of hot supply air directly back into the system artificially raising supply temp and continues to cause it to trip on limit switch even when running within temperature rise specs.  Used tape to seal off humidifier pipe to block airflow, and bumped blower speed to Med-Hi from Med to get the temperature rise more towards the middle of the temperature rise. With all current settings, system is Upon arrival, system was off. Test ran operation through jumper wire on control board. Tested gas pressure and temperature rise as the mentioned 4 flash code indicates an airflow issue and/or overheating. Gas pressure on initial startup and at 3.9inwc when the system specifications are 3.2-3.8inwc. Set gas pressure to 3.2inwc. System was still on the  higher end of the temperature rise range of 40-70F at 65F. After some further testing, it was found that the bypass humidifier does not have an airflow damper installed, nor the inner bracket with a humidifier pad. This is allowing an excessive amount of hot supply air directly back into the system artificially raising supply temp and continues to cause it to trip on limit switch even when running within temperature rise specs.  Used tape to seal off humidifier pipe to block airflow, and bumped blower speed to Med-Hi from Med to get the temperature rise more towards the middle of the temperature rise. With all current settings, system is

Nate G.

Nate G. Job Checkin

Rollout safety tripped Reset Run tested furnace for a while to be sure its not a small heat exchanger crack opening up after extended run time Checked intake and exhaust venting: no ice or snow covering intake or exhaust pipes Blew out Condensate trap from both inlet lines Checked inducer outlet coupling elbow drain port for blockage Found the inducer was filling with water after a period of time Per Goodman tech support, added a trapped drain to the inducer Furnace operating normally at this time


Brandon P.

Brandon P. Job Checkin

10 E10 comp monitor codes present due to bad 40uf compressor capacitor. Waterfurnace confirmed parts and labor warranty good until 1-7-2030. Replaced 40uf capacitor with new capacitor and test ran operation. During test run, found that ground loop water pressure was low at 30psi. Pressurized system to 60psi with house water. System is currently running with no other issues found or suspected.


Jason D.

Jason D. Job Checkin

11/24/2025 6:02:56 PM - Option 2 Install New Daikin HVAC System Modulating Variable Speed Furnace: Model #: DR97MC0803BNA Serial #: 2502107727 80,000 BTU's - 97% AFUE Side Discharge Air Conditioner: Model #: DC6VSS3610 Serial #: Y008393 3 Ton - 17.2 SEER2 Indoor Coil: Model #: CAPEA3626C3 Serial #: 2411127426 *Daikin One+ Thermostat: DTST-TOU-A Serial #: EA2503602143 Installation: * Additional Services - New PVC Furnace Vents. Level 1 * Reconnect to existing electric * Transition to existing supply and return ductwork * Start up and commission new system * Aprilaire 1210 (20x25) Media Air Cleaner Warranty: 12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed) 20 Year Daikin manufacturers Exchanger Warranty (Annual maintenance must be performed)


11/24/2025 6:02:56 PM - Option 2

Install New Daikin HVAC System
Modulating Variable Speed Furnace:
Model #: DR97MC0803BNA 
Serial #: 2502107727
80,000 BTU's - 97% AFUE
Side Discharge Air Conditioner:
Model #: DC6VSS3610
Serial #: Y008393
3 Ton - 17.2 SEER2
Indoor Coil:
Model #: CAPEA3626C3
Serial #: 2411127426
*Daikin One+ Thermostat: DTST-TOU-A
Serial #: EA2503602143
 
Installation:
* Additional Services - New PVC Furnace Vents. Level 1
* Reconnect to existing electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* Aprilaire 1210 (20x25) Media Air Cleaner
 
Warranty:
12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
20 Year Daikin manufacturers Exchanger Warranty (Annual maintenance must be performed)


11/24/2025 6:02:56 PM - Option 2

Install New Daikin HVAC System
Modulating Variable Speed Furnace:
Model #: DR97MC0803BNA 
Serial #: 2502107727
80,000 BTU's - 97% AFUE
Side Discharge Air Conditioner:
Model #: DC6VSS3610
Serial #: Y008393
3 Ton - 17.2 SEER2
Indoor Coil:
Model #: CAPEA3626C3
Serial #: 2411127426
*Daikin One+ Thermostat: DTST-TOU-A
Serial #: EA2503602143
 
Installation:
* Additional Services - New PVC Furnace Vents. Level 1
* Reconnect to existing electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* Aprilaire 1210 (20x25) Media Air Cleaner
 
Warranty:
12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
20 Year Daikin manufacturers Exchanger Warranty (Annual maintenance must be performed)

Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed basement Check filter - Aprilaire 501 electronic core is due ASAP Clean flame sensor Inspect burners - No concerns Ohm test igniter: 59.8 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - 2”pvc no concerns Set thermostat for heat Check amp draw on blower motor: 3.42 Check amp draw on inducer motor:0.79 Check delta T - 59° Furnace is in optimal running conditions Gas heating preventative maintenance performed closet 2nd floor Check filter - 20x25x1 clean Clean flame sensor Inspect burners - clean Ohm test igniter: 54.2 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: Inspect exhaust flu - 2”PVC no concerns Set thermostat for heat Check amp draw on blower motor: 2.92 Check amp draw on inducer motor:0.42 Check delta T - 53° Furnace is in running conditions at this time. 2nd floor system was showing signs of gas valve failure. Un


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on two Carrier high efficiency furnaces. Replaced both 20x25x4 air filters. Humidifier pads in new condition. Cleaned flame sensors and checked ignitors. Visual inspection of burners. Flush condensation trap and drain lines. Run test each system in both stages of heating. Both are operating properly and within specs for temperature rise, and blower and inducer motor amp draw. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Run test humidifiers during heating operations. Sunny explained colder temperature in smaller kitchen area. Dampened down vents near thermostat and sensor to prevent short cycling, and to force more air into that area. Also adjusted continuous fan speed up to move more air during idle time, and turned Dan more to on to continuously circulate air to even out temperature between rooms.


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 16x25x4 due soon Clean flame sensor Inspect burners - mildly dusty brushed clean Ohm test igniter: 56.8 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns 2” pvc Set thermostat for heat Check amp draw on blower motor: 3.2 Check amp draw on inducer motor:0.48 Check delta T - 58° Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Humidifier was leaking after solenoid valve at gray supply line for humidifier. Tighten fitting in test system verify no more leaks. Informed homeowner of required maintenance for accessories.