725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for delaware, oh

Rated 4.9 out of 5 stars based on 27 customer reviews

Attention to detail

Chris has a great attention to detail and is always willing to help us with our Energy Star Program

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Quality personnel

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service Professional employees!

Very responsive and gets the job done!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great communication

Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and quick response!

Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.

  • Overall Experience
  • Quality
  • Price
  • Convenience

A professional in your own neighborhood

I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs

  • Overall Experience
  • Quality
  • Price
  • Convenience

Takes Pride

Chris takes pride in his works and cares about things getting done properly!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Always on top of his game and knows everything that’s is happening in all his communities.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, arrived on time and the price was great

Great service and great price!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, as always

Great company. Always feel like they are looking out for me, from the time I call and make my bi-yearly appointments to the time the maintenance is complete and they walk out the door....top performance, top customer service. Thank you.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Had service performed

Hi quality and knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Technician is competent and keeps to schedules.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Courteous and knowledgeable technician

Seth provided excellent service as well as a descriptive report of all work done. He also provided some good tips to keep that we could do to keep things in proper working order. Thanks.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always great, professional service

Very positive experience. Seth answered all questions and concerns we had.

  • Overall Experience
  • Quality
  • Price
  • Convenience

very happy with the service

THE MAN YOU SENT WAS VERY NICE AND DID A GREAT JOB. I FEEL VERY GOOD THAT I WILL NOT HAVEANY PROBLEMS THISWINTER.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for delaware, oh

Nate G.

Nate G. Job Checkin

Rollout safety tripped Reset Run tested furnace for a while to be sure its not a small heat exchanger crack opening up after extended run time Checked intake and exhaust venting: no ice or snow covering intake or exhaust pipes Blew out Condensate trap from both inlet lines Checked inducer outlet coupling elbow drain port for blockage Found the inducer was filling with water after a period of time Per Goodman tech support, added a trapped drain to the inducer Furnace operating normally at this time


Brandon P.

Brandon P. Job Checkin

10 E10 comp monitor codes present due to bad 40uf compressor capacitor. Waterfurnace confirmed parts and labor warranty good until 1-7-2030. Replaced 40uf capacitor with new capacitor and test ran operation. During test run, found that ground loop water pressure was low at 30psi. Pressurized system to 60psi with house water. System is currently running with no other issues found or suspected.


Jason D.

Jason D. Job Checkin

11/24/2025 6:02:56 PM - Option 2 Install New Daikin HVAC System Modulating Variable Speed Furnace: Model #: DR97MC0803BNA Serial #: 2502107727 80,000 BTU's - 97% AFUE Side Discharge Air Conditioner: Model #: DC6VSS3610 Serial #: Y008393 3 Ton - 17.2 SEER2 Indoor Coil: Model #: CAPEA3626C3 Serial #: 2411127426 *Daikin One+ Thermostat: DTST-TOU-A Serial #: EA2503602143 Installation: * Additional Services - New PVC Furnace Vents. Level 1 * Reconnect to existing electric * Transition to existing supply and return ductwork * Start up and commission new system * Aprilaire 1210 (20x25) Media Air Cleaner Warranty: 12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed) 20 Year Daikin manufacturers Exchanger Warranty (Annual maintenance must be performed)


11/24/2025 6:02:56 PM - Option 2

Install New Daikin HVAC System
Modulating Variable Speed Furnace:
Model #: DR97MC0803BNA 
Serial #: 2502107727
80,000 BTU's - 97% AFUE
Side Discharge Air Conditioner:
Model #: DC6VSS3610
Serial #: Y008393
3 Ton - 17.2 SEER2
Indoor Coil:
Model #: CAPEA3626C3
Serial #: 2411127426
*Daikin One+ Thermostat: DTST-TOU-A
Serial #: EA2503602143
 
Installation:
* Additional Services - New PVC Furnace Vents. Level 1
* Reconnect to existing electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* Aprilaire 1210 (20x25) Media Air Cleaner
 
Warranty:
12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
20 Year Daikin manufacturers Exchanger Warranty (Annual maintenance must be performed)


11/24/2025 6:02:56 PM - Option 2

Install New Daikin HVAC System
Modulating Variable Speed Furnace:
Model #: DR97MC0803BNA 
Serial #: 2502107727
80,000 BTU's - 97% AFUE
Side Discharge Air Conditioner:
Model #: DC6VSS3610
Serial #: Y008393
3 Ton - 17.2 SEER2
Indoor Coil:
Model #: CAPEA3626C3
Serial #: 2411127426
*Daikin One+ Thermostat: DTST-TOU-A
Serial #: EA2503602143
 
Installation:
* Additional Services - New PVC Furnace Vents. Level 1
* Reconnect to existing electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* Aprilaire 1210 (20x25) Media Air Cleaner
 
Warranty:
12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
20 Year Daikin manufacturers Exchanger Warranty (Annual maintenance must be performed)

Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed basement Check filter - Aprilaire 501 electronic core is due ASAP Clean flame sensor Inspect burners - No concerns Ohm test igniter: 59.8 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - 2”pvc no concerns Set thermostat for heat Check amp draw on blower motor: 3.42 Check amp draw on inducer motor:0.79 Check delta T - 59° Furnace is in optimal running conditions Gas heating preventative maintenance performed closet 2nd floor Check filter - 20x25x1 clean Clean flame sensor Inspect burners - clean Ohm test igniter: 54.2 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: Inspect exhaust flu - 2”PVC no concerns Set thermostat for heat Check amp draw on blower motor: 2.92 Check amp draw on inducer motor:0.42 Check delta T - 53° Furnace is in running conditions at this time. 2nd floor system was showing signs of gas valve failure. Un


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on two Carrier high efficiency furnaces. Replaced both 20x25x4 air filters. Humidifier pads in new condition. Cleaned flame sensors and checked ignitors. Visual inspection of burners. Flush condensation trap and drain lines. Run test each system in both stages of heating. Both are operating properly and within specs for temperature rise, and blower and inducer motor amp draw. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Run test humidifiers during heating operations. Sunny explained colder temperature in smaller kitchen area. Dampened down vents near thermostat and sensor to prevent short cycling, and to force more air into that area. Also adjusted continuous fan speed up to move more air during idle time, and turned Dan more to on to continuously circulate air to even out temperature between rooms.


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 16x25x4 due soon Clean flame sensor Inspect burners - mildly dusty brushed clean Ohm test igniter: 56.8 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns 2” pvc Set thermostat for heat Check amp draw on blower motor: 3.2 Check amp draw on inducer motor:0.48 Check delta T - 58° Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Humidifier was leaking after solenoid valve at gray supply line for humidifier. Tighten fitting in test system verify no more leaks. Informed homeowner of required maintenance for accessories.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on two Daikin high efficiency gas furnaces and a Daikin mini split. For gas furnaces, cleaned flame sensors and checked ignitors. Visual inspection of burners. Flush condensation trap and drain lines. Replaced air filters and checked humidifier pads. Humidifier dampers open. Run test units in heating mode from thermostats. Both systems are operating properly and within specs for temperature rise, blower and inducer motor amp draw. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Tested operation of humidifiers during heating tests. For mini split, cleaned filters and inspected outdoor coils. Test ran operation of heating. Did not check refrigerant as there is no issues suspected at this time. All systems are operational and ready for Winter.


Graham M.

Graham M. Job Checkin

Replace Communicating thermostat TPCC32U Replace AXB control board Test run system verify proper operation after repairs. System is running in great conditions post repairs, had to flush air from the loop from when repairs were made but things quickly flushed through and went back to normal. Unit heating with 30° rise without emergency strips.


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 210 popup new today homeowner supply Clean flame sensor Inspect burners - clean Ohm test igniter: 54.6 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 5.2 Check amp draw on inducer motor:0.48 Check delta T - 58° Furnace is in optimal running conditions


Nate G.

Nate G. Job Checkin

Performed heating maintenance 2020 Lennox 2 stage 96% efficient furnace Repaired a water leak off the inducer outlet coupling bottom hose clamp Pulled and cleaned flame sensor Condensate trap clear Honeywell POPUP2200 in OK shape Discussed humidifier, wishes to leave it off Cannot reach the damper to it because of the finished wall behind the furnace Burners are in good shape Blew out condensate line from inducer outlet to collector box High fire gas pressure 3.5" temp rise 51⁰ Low fire 1.7" temp rise 45⁰ 2024 Bryant 2stage 96% Wired thermostat for two stage heating control Cleaned flame sensor Replaced 210 air filter Trap clear High fire 3.4" Temp rise 56⁰ Low fire 1.7" Temp rise 46⁰ No concerns found at this time


Nate G.

Nate G. Job Checkin

Replace OEM ABC control board for WaterFurnace 5 Series geo Verified correct operation


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x1 new today Clean flame sensor Inspect burners - clean no concerns Ohm test igniter: 62.1 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - 2” pvc no concerns Set thermostat for heat Check amp draw on blower motor: 4.2 Check amp draw on inducer motor:0.89 Check delta T - 53° Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 213 popup clean good for season Clean flame sensor Inspect burners - clean no concerns Ohm test igniter: 53.6 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - 2” PVC Set thermostat for heat Check amp draw on blower motor: 3.9 Check amp draw on inducer motor:0.45 5mfd @4.71 Check delta T - 53° rise Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Upon arrival inspected system and found multiple critical errors and multiple other errors. Upon further inspection found AXB board will not communicate. As well as thermostat. Homeowners informed me they removed stat from the wall and replaced it trying to restart system and after that stat got hot and went blank. Communication error present for AXB and thermostat. Install t4 stat and start system under emergency auxiliary heat. Allowing system to operate under emergency functions until system can be further inspected and repaired or replaced due to repair costs.