725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for delaware, oh

Rated 4.9 out of 5 stars based on 27 customer reviews

Attention to detail

Chris has a great attention to detail and is always willing to help us with our Energy Star Program

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Quality personnel

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service Professional employees!

Very responsive and gets the job done!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great communication

Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and quick response!

Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.

  • Overall Experience
  • Quality
  • Price
  • Convenience

A professional in your own neighborhood

I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs

  • Overall Experience
  • Quality
  • Price
  • Convenience

Takes Pride

Chris takes pride in his works and cares about things getting done properly!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Always on top of his game and knows everything that’s is happening in all his communities.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, arrived on time and the price was great

Great service and great price!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, as always

Great company. Always feel like they are looking out for me, from the time I call and make my bi-yearly appointments to the time the maintenance is complete and they walk out the door....top performance, top customer service. Thank you.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Had service performed

Hi quality and knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Technician is competent and keeps to schedules.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Courteous and knowledgeable technician

Seth provided excellent service as well as a descriptive report of all work done. He also provided some good tips to keep that we could do to keep things in proper working order. Thanks.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always great, professional service

Very positive experience. Seth answered all questions and concerns we had.

  • Overall Experience
  • Quality
  • Price
  • Convenience

very happy with the service

THE MAN YOU SENT WAS VERY NICE AND DID A GREAT JOB. I FEEL VERY GOOD THAT I WILL NOT HAVEANY PROBLEMS THISWINTER.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for delaware, oh

Brandon P.

Brandon P. Job Checkin

2019 Comfortmaker AC operating in great condition. Aprilaire 210 air filter in good condition. Visual inspection of indoor coil. Flush drain pan and drain lines. Run test unit in cooling mode from thermostat. Delta t of 21F with supply temp of 50F. Initial operating showed that Refrigerant pressures were under spec with a subcool of 0.7F when data plate calls for 11F subcool. Charge in 180z of r410a to bring refrigerant pressures within spec. Current refrigerant pressures are as follows, high 315psi with 12F SC, low 110psi with 12F SH. System is operating properly, efficiently and ready for Summer.

2019 Comfortmaker AC operating in great condition. Aprilaire 210 air filter in good condition. Visual inspection of indoor coil. Flush drain pan and drain lines. Run test unit in cooling mode from thermostat. Delta t of 21F with supply temp of 50F. Initial operating showed that Refrigerant pressures were under spec with a subcool of 0.7F when data plate calls for 11F subcool. Charge in 180z of r410a to bring refrigerant pressures within spec. Current refrigerant pressures are as follows, high 315psi with 12F SC, low 110psi with 12F SH. System is operating properly, efficiently and ready for Summer.

Brandon P.

Brandon P. Job Checkin

2023 Daikin Heat Pump running in new condition. Aprilaire #413 filter is new today. Visual inspection of indoor coil. Flush drain pan and drain trap. Run test unit in charge mode from thermostat. Delta t of 18F with supply temp of 54F. Refrigerant pressures are within spec. Pressures and temperatures read using Daikin D-Checker. High 270psi with 9F SC, low 125psi with 12F SH. Outdoor coils are in clean condition and unjtnis level. System is operating properly, efficiently and ready for Summer.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection performed on two Trane XR AC units. Both 20x25x1 air filters are new today. Visual inspection of indoor coils. Flush condensation drain pans and drain lines. Run test units in cooling mode from respective thermostats. Both systems are operating properly within specifications for air delta t and refrigeration pressures and temperatures. Dual run capacitors are within spec. Outdoor fan motors and compressors are all operating within spec. Outdoor condensing coils are clean. System are operating properly, efficiently and ready for Summer.


Graham M.

Graham M. Job Checkin

Perform cooling PMI check refrigerant pressures Check blower speeds Delta T at 24° Ac running with 9° subcool Capacitor in spec 40+5 full Ecm blower Filter due soon Ac ready for the season


Brandon P.

Brandon P. Job Checkin

2019 Goodman AC running in new condition. 20x25x1 air filter in good condition and on schedule with homeowner. Visual inspection of indoor. Flush condensation drain pan and drain lines. Inspect blower system. Run test unit in cooling mode from thermostat. Delta t of 20F with supply temp of 46F. Outdoor unit coils are clean. Unit is level on brackets. 50/5 capacitor is within spec. Refrigerant pressures are within spec. High 265psi with 8F SC, low 105psi with 14F SH. System is operating properly, efficiently and ready for Summer.

2019 Goodman AC running in new condition. 20x25x1 air filter in good condition and on schedule with homeowner. Visual inspection of indoor. Flush condensation drain pan and drain lines. Inspect blower system. Run test unit in cooling mode from thermostat. Delta t of 20F with supply temp of 46F. Outdoor unit coils are clean. Unit is level on brackets. 50/5 capacitor is within spec. Refrigerant pressures are within spec. High 265psi with 8F SC, low 105psi with 14F SH. System is operating properly, efficiently and ready for Summer.

seth p.

seth p. Job Checkin

Upon arrival the thermostat was turned off At initial test run everything ran normal with no complications or hesitations. Air filter was replaced one week ago and is still in like new condition, thermostat turned on and cycled both low and high stages with no overheating. Combustion air filter clean, inspect and resurface flame sensor. System is running on thermostat heat mode. Unsure of the daily schedule or home and away settings but the system is functioning correctly. Corinthian builder staff suspects homeowner turned thermostat off yesterday but forgot to turn back on


seth p.

seth p. Job Checkin

No heat service call, service code 3 no pressure switch activation with heat call. Confirmed bad bearings locked up on 80% combustion blower assembly. Shop vac equipment, resurface flame sensor, wire brush burner tips, install new OEM combustion blower assembly Cooling system PMI, test run equipment in single stage cooling mode and confirm 52° supply temperature. PSC blower speed set to high, evaporator A coil encased in the ductwork plenum and not accessible for inspection, 3/4 PVC pipe also sealed with no service ports. Outdoor unit 50 to 75% matted over and clogged with outdoor airborne debris and mulch bed dirt. Heavy duty water flush on condenser coils, electrical compartment cleaning and inspection, replace worn out 370 VAC power supply rated at 35 + 5 UF Return thermostat to heating mode Air filter is it acceptable and on schedule with homeowners HW-16x25x4 Emerson White-Rodgers WA digital thermostat set to two-stage heat


Brandon P.

Brandon P. Job Checkin

Thermostats were programmed incorrectly. Set auto changeover differential to 0F. This will make sure that the system. Will come in in either heating or cooling when either stet temperature is reached. It is very important to leave a 3 degree difference in heat a d cool setpoint to avoid the ac and furnace switching on and off constantly. Recommend a larger fin 14x6 grill for downstairs room to prevent harmonic vibration noises from airflow.


Brandon P.

Brandon P. Job Checkin

Drain and remove existing water heater Install new water heater and reconnect to geothermal HWG lines Stop leak at boiler drain valve on cold water supply


Drain and remove existing water heater 
Install new water heater and reconnect to geothermal HWG lines
Stop leak at boiler drain valve on cold water supply

Brandon P.

Brandon P. Job Checkin

Was able walk him through on phone. No issues are suspected as system came on and operated in heat, cool, and fan only while on the phone.


Graham M.

Graham M. Job Checkin

Upon arrival inspected furnace and discovered bad igniter unit would attempt to cycle but couldnt pass ignition. Igniter ohms open. Remove and replace igniter with hot rod igniter from van stock. Direct replacement to old hot rod igniter that went bad. Test ran furnace and unit cycles as should with new igniter


Nate G.

Nate G. Job Checkin

Service warranty: Check heat pump operation since the electrician has replaced the disconnect box. Heat pump is functioning normally at this time. It is too cold to do a cooling maintenance today.


Nate G.

Nate G. Job Checkin

Service disconnect for the heat pump is melted and no providing power to the unit. Disconnect needs replaced by the electrician.

Service disconnect for the heat pump is melted and no providing power to the unit.  Disconnect needs replaced by the electrician.

Nate G.

Nate G. Job Checkin

Black rubber plug above the Condensate trap was no inserted fully from the factory. Water was dripping from that plug. Pushed the plug in and dried everything off.

Black rubber plug above the Condensate trap was no inserted fully from the factory.   Water was dripping from that plug.  Pushed the plug in and dried everything off.

seth p.

seth p. Job Checkin

2011 water furnace and vision two stage 049. Are the homeowner the system has never been inspected since the install. Regular filter changes once a year. System locked out on condensate drain overflow switch roughly 5 years ago Primary concern at today's visit high electric bills over the past several months. Initial overall visual inspection found several points of concern. 1) comforter alert is alerting service code 6 indicating open start circuit. Compressor run capacitor is swollen and burned out 2) ground loops books back should be 50 to 75 PSI in winter and is reading 15 PSI in the off state 3) air coil has light but noticeable surface matting from normal house dust Shop vac all equipment top to bottom including filter rack compressor compartment blower compartment and cabinet exterior. Homeowner performed air coil cleaning with compressed air while on site today. Flush condensate drain trap, refresherized ground loops from 15 PSI to 70 PSI, test run 15KW auxiliary heat s