725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for delaware, oh

Rated 4.9 out of 5 stars based on 27 customer reviews

Attention to detail

Chris has a great attention to detail and is always willing to help us with our Energy Star Program

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Quality personnel

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service Professional employees!

Very responsive and gets the job done!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great communication

Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and quick response!

Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.

  • Overall Experience
  • Quality
  • Price
  • Convenience

A professional in your own neighborhood

I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs

  • Overall Experience
  • Quality
  • Price
  • Convenience

Takes Pride

Chris takes pride in his works and cares about things getting done properly!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Always on top of his game and knows everything that’s is happening in all his communities.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, arrived on time and the price was great

Great service and great price!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, as always

Great company. Always feel like they are looking out for me, from the time I call and make my bi-yearly appointments to the time the maintenance is complete and they walk out the door....top performance, top customer service. Thank you.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Had service performed

Hi quality and knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Technician is competent and keeps to schedules.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Courteous and knowledgeable technician

Seth provided excellent service as well as a descriptive report of all work done. He also provided some good tips to keep that we could do to keep things in proper working order. Thanks.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always great, professional service

Very positive experience. Seth answered all questions and concerns we had.

  • Overall Experience
  • Quality
  • Price
  • Convenience

very happy with the service

THE MAN YOU SENT WAS VERY NICE AND DID A GREAT JOB. I FEEL VERY GOOD THAT I WILL NOT HAVEANY PROBLEMS THISWINTER.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for delaware, oh

Graham M.

Graham M. Job Checkin

Upon arrival inspected system and found inducer motor was seized and not operating. Quote replacement inducer motor and test run system, furnace blower not cycling after heat up cycle. Blower getting power but will not come on. Capacitor 10mfd @ 10mfd motor bad and needs replaced. Will have to return tomorrow to replace furnace blower motor. Remove and replace blower motor test run heat. Clean blower wheel and housing of dust buildup due to electronic air filter. No concerns post repair

Upon arrival inspected system and found inducer motor was seized and not operating. Quote replacement inducer motor and test run system, furnace blower not cycling after heat up cycle. Blower getting power but will not come on. Capacitor 10mfd @ 10mfd motor bad and needs replaced. Will have to return tomorrow to replace furnace blower motor. 


Remove and replace blower motor test run heat. Clean blower wheel and housing of dust buildup due to electronic air filter. No concerns post repair

Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 16x25x1 clean Clean flame sensor Inspect burners - no concerns Ohm test igniter: 54.6 Inspect wiring for loose connections and/or hot spots - no concerns Check humidifier pad: n/a Inspect exhaust flu - 80% no concerns Set thermostat for heat Check amp draw on blower motor: 3.2 Check amp draw on inducer motor:0.6 Check delta T - 49° Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Remove and replace Goodman single stage gas valve due to unit not staying on. With power continuing to valve


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Carrier high efficiency furnace. 20x25x4 air filter is new today. Clean flame sensor and check ignitor ohms. Flush condensation trap and drain lines. Run test unit in heating mode. Initial startup shows furnace operating with 3.8inwc of gas supply. This is at the top of the range and can cause short-cycling. Adjusted gas pressure to 3.0inwc at the low end of the range. This will prevent short cycling and allow the furnace to run longer and more evenly heat the house. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 16x25x1 clean Clean flame sensor Inspect burners - clean no concerns Ohm test igniter: 49.2 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: clean from spring Inspect exhaust flu - no concerns 2” pvc Set thermostat for heat Check amp draw on blower motor: 1.0 Check amp draw on inducer motor:2.34 Check delta T - 54° Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x1 new today Clean flame sensor Inspect burners - no concerns Ohm test igniter: 64.2 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.91 Check amp draw on inducer motor:0.62 Check delta T - 52° Heat pump operational and defrost functioning Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Remove faulty, pressure switch, and replaced with factory warranty part


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x1 Clean flame sensor Inspect burners - no concerns Ohm test igniter: 48.3 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - 2” pvc Set thermostat for heat Check amp draw on blower motor: 3.21 Check amp draw on inducer motor:0.38 Check delta T - 59° Furnace is in optimal running conditions


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Comfortmaker furnace. 16x25x4 air filter in decent condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Humidifier damper is open, pad in good condition. Test run system in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. 4" galvanized B-vent in good condition and no sign of leaks. 0PPM CO detected during testing. Humidifier tested during heating operation. System is operating properly, efficiently and ready for Winter.


Jason D.

Jason D. Job Checkin

SOLD: 12/12/2025 1:44:19 PM - Option 3 Install New Daikin HVAC System Two Stage Variable Speed Furnace: Model #: DR80TC0603BN Serial #: 2509017663 60,000 BTU's - 80% AFUE High Efficiency, Side Discharge Air Conditioner: Model #: DC6VSS3010A Serial #: 2506183096 2.5 Ton - 17.2 SEER2 Indoor Coil: Model #: CAPEA3022B3 Serial #: 2502177225 Daikin One Touch Thermostat: Model# DTST-TOU-A Serial #: EA2503602130 Installation: * Reconnect to existing electric * Transition to existing supply and return ductwork * Start up and commission new system * Aprilaire 1210 (20x25) Media Air Cleaner Warranty: 12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed) 20 Year Daikin manufacturers Exchanger Warranty (Annual maintenance must be performed)


SOLD: 12/12/2025 1:44:19 PM - Option 3

Install New Daikin HVAC System
Two Stage Variable Speed Furnace:
Model #: DR80TC0603BN 
Serial #: 2509017663
60,000 BTU's - 80% AFUE
High Efficiency, Side Discharge Air Conditioner:
Model #: DC6VSS3010A
Serial #: 2506183096
2.5 Ton - 17.2 SEER2
Indoor Coil:
Model #: CAPEA3022B3
Serial #: 2502177225
Daikin One Touch Thermostat: 
Model# DTST-TOU-A
Serial #: EA2503602130
 
Installation:
* Reconnect to existing electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* Aprilaire 1210 (20x25) Media Air Cleaner
 
Warranty:
12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
20 Year Daikin manufacturers Exchanger Warranty (Annual maintenance must be performed)

SOLD: 12/12/2025 1:44:19 PM - Option 3

Install New Daikin HVAC System
Two Stage Variable Speed Furnace:
Model #: DR80TC0603BN 
Serial #: 2509017663
60,000 BTU's - 80% AFUE
High Efficiency, Side Discharge Air Conditioner:
Model #: DC6VSS3010A
Serial #: 2506183096
2.5 Ton - 17.2 SEER2
Indoor Coil:
Model #: CAPEA3022B3
Serial #: 2502177225
Daikin One Touch Thermostat: 
Model# DTST-TOU-A
Serial #: EA2503602130
 
Installation:
* Reconnect to existing electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* Aprilaire 1210 (20x25) Media Air Cleaner
 
Warranty:
12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
20 Year Daikin manufacturers Exchanger Warranty (Annual maintenance must be performed)

Graham M.

Graham M. Job Checkin

System was satisfying, desired temperature upon arrival. Inspected system and found no errors present. Homeowner informed me that furnace was back in a code one when he had to reset it. Informed homeowner that we will have to order the P1 pressure switch. To resolve issue due to a failed switch. Inspected drain and everything was clear and inducer motor was not pulling high amps. It was staying at 2.4 operational. Rated 2.7 Fla. unable to quote tonight due to being passed Goodman hours.

System was satisfying, desired temperature upon arrival. Inspected system and found no errors present. Homeowner informed me that furnace was back in a code one when he had to reset it. Informed homeowner that we will have to order the P1 pressure switch. To resolve issue due to a failed switch. Inspected drain and everything was clear and inducer motor was not pulling high amps. It was staying at 2.4 operational. Rated 2.7 Fla. unable to quote tonight due to being passed Goodman hours.

Brandon P.

Brandon P. Job Checkin

Basement East system is frozen solid. Turn fan on and will return for diagnosis once unit has thawed out.


Brandon P.

Brandon P. Job Checkin

Replacement warranty. Upon arrival, thermostat was in off mode. Inspected furnace for any obvious issues and found d that the furnace control board was not being powered. Removed door and pushed in door switch to check for power. With door switch pushed in by hand, the system came on. Put bottom door back on and noticed that the door was not pushing the door switch in all of the way as the door switch was hanging lower than it should be. Adjusted door switch for proper height and put door back on. With door on, system now has power. Turned thermostat to heating to check for any other issues. None found or suspected. Bob mentioned he would like a quote to install a ductless mini split in the garage. Photos on file of furnace for humidifier install, aswell as interior and exterior photos for mini split install.

Replacement warranty.
Upon arrival, thermostat was in off mode. Inspected furnace for any obvious issues and found d that the furnace control board was not being powered. Removed door and pushed in door switch to check for power. With door switch pushed in by hand, the system came on. Put bottom door back on and noticed that the door was not pushing the door switch in all of the way as the door switch was hanging lower than it should be. Adjusted door switch for proper height and put door back on. With door on, system now has power. Turned thermostat to heating to check for any other issues. None found or suspected.

Bob mentioned he would like a quote to install a ductless mini split in the garage. Photos on file of furnace for humidifier install, aswell as interior and exterior photos for mini split install. Replacement warranty.
Upon arrival, thermostat was in off mode. Inspected furnace for any obvious issues and found d that the furnace control board was not being powered. Removed door and pushed in door switch to check for power. With door switch pushed in by hand, the system came on. Put bottom door back on and noticed that the door was not pushing the door switch in all of the way as the door switch was hanging lower than it should be. Adjusted door switch for proper height and put door back on. With door on, system now has power. Turned thermostat to heating to check for any other issues. None found or suspected.

Bob mentioned he would like a quote to install a ductless mini split in the garage. Photos on file of furnace for humidifier install, aswell as interior and exterior photos for mini split install.

Graham M.

Graham M. Job Checkin

Cycle system and found intermittent blower speed operation. Repaired blower speed electrical connections and blower is operating correct at this time. Returned system to normal operation.


Brandon P.

Brandon P. Job Checkin

Upon arrival, system was off. Test ran operation through jumper wire on control board. Tested gas pressure and temperature rise as the mentioned 4 flash code indicates an airflow issue and/or overheating. Gas pressure on initial startup and at 3.9inwc when the system specifications are 3.2-3.8inwc. Set gas pressure to 3.2inwc. System was still on the higher end of the temperature rise range of 40-70F at 65F. After some further testing, it was found that the bypass humidifier does not have an airflow damper installed, nor the inner bracket with a humidifier pad. This is allowing an excessive amount of hot supply air directly back into the system artificially raising supply temp and continues to cause it to trip on limit switch even when running within temperature rise specs. Used tape to seal off humidifier pipe to block airflow, and bumped blower speed to Med-Hi from Med to get the temperature rise more towards the middle of the temperature rise. With all current settings, system is

Upon arrival, system was off. Test ran operation through jumper wire on control board. Tested gas pressure and temperature rise as the mentioned 4 flash code indicates an airflow issue and/or overheating. Gas pressure on initial startup and at 3.9inwc when the system specifications are 3.2-3.8inwc. Set gas pressure to 3.2inwc. System was still on the  higher end of the temperature rise range of 40-70F at 65F. After some further testing, it was found that the bypass humidifier does not have an airflow damper installed, nor the inner bracket with a humidifier pad. This is allowing an excessive amount of hot supply air directly back into the system artificially raising supply temp and continues to cause it to trip on limit switch even when running within temperature rise specs.  Used tape to seal off humidifier pipe to block airflow, and bumped blower speed to Med-Hi from Med to get the temperature rise more towards the middle of the temperature rise. With all current settings, system is Upon arrival, system was off. Test ran operation through jumper wire on control board. Tested gas pressure and temperature rise as the mentioned 4 flash code indicates an airflow issue and/or overheating. Gas pressure on initial startup and at 3.9inwc when the system specifications are 3.2-3.8inwc. Set gas pressure to 3.2inwc. System was still on the  higher end of the temperature rise range of 40-70F at 65F. After some further testing, it was found that the bypass humidifier does not have an airflow damper installed, nor the inner bracket with a humidifier pad. This is allowing an excessive amount of hot supply air directly back into the system artificially raising supply temp and continues to cause it to trip on limit switch even when running within temperature rise specs.  Used tape to seal off humidifier pipe to block airflow, and bumped blower speed to Med-Hi from Med to get the temperature rise more towards the middle of the temperature rise. With all current settings, system is