725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for delaware, oh

Rated 4.9 out of 5 stars based on 27 customer reviews

Attention to detail

Chris has a great attention to detail and is always willing to help us with our Energy Star Program

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Quality personnel

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service Professional employees!

Very responsive and gets the job done!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great communication

Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and quick response!

Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.

  • Overall Experience
  • Quality
  • Price
  • Convenience

A professional in your own neighborhood

I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs

  • Overall Experience
  • Quality
  • Price
  • Convenience

Takes Pride

Chris takes pride in his works and cares about things getting done properly!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Always on top of his game and knows everything that’s is happening in all his communities.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, arrived on time and the price was great

Great service and great price!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, as always

Great company. Always feel like they are looking out for me, from the time I call and make my bi-yearly appointments to the time the maintenance is complete and they walk out the door....top performance, top customer service. Thank you.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Had service performed

Hi quality and knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Technician is competent and keeps to schedules.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Courteous and knowledgeable technician

Seth provided excellent service as well as a descriptive report of all work done. He also provided some good tips to keep that we could do to keep things in proper working order. Thanks.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always great, professional service

Very positive experience. Seth answered all questions and concerns we had.

  • Overall Experience
  • Quality
  • Price
  • Convenience

very happy with the service

THE MAN YOU SENT WAS VERY NICE AND DID A GREAT JOB. I FEEL VERY GOOD THAT I WILL NOT HAVEANY PROBLEMS THISWINTER.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for delaware, oh

Graham M.

Graham M. Job Checkin

11/5/25 7:00pm Emergency service – upon arrival inspected furnace and found leaking by gas valve. Homeowner was interested in instant replacement. Remove and replace valve with available parts on van adjusted price accordingly for a warranty valve under after hours labor. Homeowner informed me of a technician previously adjusting airflow on the furnace downstairs, giving him more problems than solution. He wanted me to convert it back. I believe I have converted it back to the original settings. It was on. I changed orange to gray. If things aren’t better next season, we will further address. Back in 2023 homeowner previously requested Brandon to quote ERV addition for attic, his original request was denied due to unavailability new request is being sent in to office and we will update with information when we have it. Gas heating preventative maintenance performed Check filter - 20x25x4 filter due by December. Clean flame sensor Ohm test igniter: 54.3 Inspect wiring for loose con


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Bryant air handler unit. Current 20x20x1 air filter is in good condition. Left new 20x20x1 air filter with other new air filters. Inspected air handler for any loose wiring internally. None found. Checked over system settings to verify proper setup. Test ran operation of electric heat strips. All strips are operating properly. Tested operation of heat pump heating. Did not check refrigerant as there is no issues suspected. System is operating properly, efficiently and ready for Winter.


Graham M.

Graham M. Job Checkin

Repair 163 B unit with 163 A inducer motor. 163 B heating after motor replacement, original motor in unit was seizing and extremely loud. Unit is severely rusty and in majorly poor shape. 163 unit is now missing 1/2 of its parts to keep upstairs unit alive. Both in need of replacement.

Repair 163 B unit with 163 A inducer motor. 163 B heating after motor replacement, original motor in unit was seizing and extremely loud. Unit is severely rusty and in majorly poor shape. 163 unit is now missing 1/2 of its parts to keep upstairs unit alive. Both in need of replacement.

Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x1 new today Clean flame sensor Ohm test igniter: 65.3ohms Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: #10 panel hiding on the back of unit due soon Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 5.2 Check amp draw on inducer motor:0.98 Check delta T - 45° Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - clean from October Clean flame sensor Flush drain trap Ohm test igniter: 68.2 ohms Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.24 Check amp draw on inducer motor:0.68 Check delta T - 45° Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - Trane clean effects vacuumed Clean flame sensor Ohm test igniter: 56.2 Inspect wiring for loose connections and/or hot spots - no concerns Check humidifier pad: new #35 and water filter today homeowner supply Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 0.62 Check amp draw on inducer motor:9.58 Check delta T - 46° Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Electric Heating preventative maintenance performed Turn heat on at thermostat New Aprilaire 410 today Check volt and amp draw on heating elements: 19amps Blower motor cap: n/a ECM DAIKIN Temp rise at — for emergency heat 55° Clean outdoor coil from dust and debris Furnace and heat pump in optimal running conditions


Nate G.

Nate G. Job Checkin

Performed heating maintenance on a 2019 Goodman 96% efficient single stage natural gas furnace 20x25x1 Filter is in good condition, do not need to change for a few months Blower wheel is clean Blower motor capacitor tested 12.8mfd, rating is 12.5 Pulled flame sensing rod and cleaned with steel wool Pulled condensate trap flushed with water in the sink Run tested furnace Adjusted burner Manifold gas pressure to 3.2"wc Blower speed is set to med-hi Temperature rise is a steady 47⁰ (specification is 35-65⁰) Furnace is in good shape and operating within manufacturer's specifications at this time


Nate G.

Nate G. Job Checkin

Performed heating maintenance on a 2021 Bryant 95% efficient single stage natural gas furnace 20x25x1 Filter is new Blower wheel is in OK condition Condensate lines are draining properly with no signs of water leakage Pulled flame sensing rod and cleaned with steel wool Run tested furnace Set burner Manifold gas pressure to 3.0"wc Temperature rise got up to 68⁰ Spec is 45-75⁰ temp rise Changed heating blower speed to the next higher setting Temperature rise came down to 62⁰ and leveled off Furnace is in good shape and operating within manufacturer's specifications at this time No concerns found with the system.


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 16x25x1 clean Clean flame sensor Ohm test igniter: 60.2 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: new today #35 Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 2.31 Check amp draw on inducer motor:0.97 Check delta T - 55° Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x4 Clean flame sensor Ohm test igniter: 58.4 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 4.9 Check amp draw on inducer motor:0.7 Check delta T - 50° Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x1 new today gold Clean flame sensor Ohm test igniter: 58.4 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - 2” pvc Set thermostat for heat Check amp draw on blower motor: 4.31 Check amp draw on inducer motor:0.98 Check delta T - 55° Furnace is in optimal running conditions


Brandon P.

Brandon P. Job Checkin

2002 Carrier durmace operating in good condition despite age. 16x25x1 air filter in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Test ran operation in heating mode. System operates within temperature rise specifications. Blower and inducer motors tested good. Humidifier is currently shut down due to broken drain hookup. Broken drain hookup will need replaced before humidifier can be operated to avoid leaking water onto the ground. Brian will the repair himself. Furnace is operating properly, efficiently and ready for Winter.

2002 Carrier durmace operating in good condition despite age. 16x25x1 air filter in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Test ran operation in heating mode. System operates within temperature rise specifications. Blower and inducer motors tested good. Humidifier is currently shut down due to broken drain hookup. Broken drain hookup will need replaced before humidifier can be operated to avoid leaking water onto the ground. Brian will the repair himself. Furnace is operating properly, efficiently and ready for Winter.

Brandon P.

Brandon P. Job Checkin

Testing operation of the unit showed that the water valve for first stage operation will not open and is causing the unit to trip on fp1 code. Wired in second stage valve to first stage to get a temporary fix to allow for unit operation. Test ran in first and second stage heating. Recommend replacement of the faulty valve for proper operation. Will prepare a quote for repairs.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on two Goodman high efficiency furnaces. Both 20x25x1 air filters are new today. Clean flame sensors and check ignitors. Visual inspection of burners. Flush condensation trap and drain lines. Basement system humidifier is operational. Pad in good condition and damper opened. Test run systems in heating mode. Both are within specifications for temperature rise. Blower and inducer motors are operating properly. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Systems are operating properly, efficiently and ready for Winter.