725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for delaware, oh

Rated 4.9 out of 5 stars based on 27 customer reviews

Attention to detail

Chris has a great attention to detail and is always willing to help us with our Energy Star Program

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Quality personnel

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service Professional employees!

Very responsive and gets the job done!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great communication

Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and quick response!

Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.

  • Overall Experience
  • Quality
  • Price
  • Convenience

A professional in your own neighborhood

I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs

  • Overall Experience
  • Quality
  • Price
  • Convenience

Takes Pride

Chris takes pride in his works and cares about things getting done properly!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Always on top of his game and knows everything that’s is happening in all his communities.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, arrived on time and the price was great

Great service and great price!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, as always

Great company. Always feel like they are looking out for me, from the time I call and make my bi-yearly appointments to the time the maintenance is complete and they walk out the door....top performance, top customer service. Thank you.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Had service performed

Hi quality and knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Technician is competent and keeps to schedules.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Courteous and knowledgeable technician

Seth provided excellent service as well as a descriptive report of all work done. He also provided some good tips to keep that we could do to keep things in proper working order. Thanks.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always great, professional service

Very positive experience. Seth answered all questions and concerns we had.

  • Overall Experience
  • Quality
  • Price
  • Convenience

very happy with the service

THE MAN YOU SENT WAS VERY NICE AND DID A GREAT JOB. I FEEL VERY GOOD THAT I WILL NOT HAVEANY PROBLEMS THISWINTER.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for delaware, oh

Graham M.

Graham M. Job Checkin

Replace Communicating thermostat TPCC32U Replace AXB control board Test run system verify proper operation after repairs. System is running in great conditions post repairs, had to flush air from the loop from when repairs were made but things quickly flushed through and went back to normal. Unit heating with 30° rise without emergency strips.


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 210 popup new today homeowner supply Clean flame sensor Inspect burners - clean Ohm test igniter: 54.6 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 5.2 Check amp draw on inducer motor:0.48 Check delta T - 58° Furnace is in optimal running conditions


Nate G.

Nate G. Job Checkin

Performed heating maintenance 2020 Lennox 2 stage 96% efficient furnace Repaired a water leak off the inducer outlet coupling bottom hose clamp Pulled and cleaned flame sensor Condensate trap clear Honeywell POPUP2200 in OK shape Discussed humidifier, wishes to leave it off Cannot reach the damper to it because of the finished wall behind the furnace Burners are in good shape Blew out condensate line from inducer outlet to collector box High fire gas pressure 3.5" temp rise 51⁰ Low fire 1.7" temp rise 45⁰ 2024 Bryant 2stage 96% Wired thermostat for two stage heating control Cleaned flame sensor Replaced 210 air filter Trap clear High fire 3.4" Temp rise 56⁰ Low fire 1.7" Temp rise 46⁰ No concerns found at this time


Nate G.

Nate G. Job Checkin

Replace OEM ABC control board for WaterFurnace 5 Series geo Verified correct operation


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x1 new today Clean flame sensor Inspect burners - clean no concerns Ohm test igniter: 62.1 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - 2” pvc no concerns Set thermostat for heat Check amp draw on blower motor: 4.2 Check amp draw on inducer motor:0.89 Check delta T - 53° Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 213 popup clean good for season Clean flame sensor Inspect burners - clean no concerns Ohm test igniter: 53.6 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - 2” PVC Set thermostat for heat Check amp draw on blower motor: 3.9 Check amp draw on inducer motor:0.45 5mfd @4.71 Check delta T - 53° rise Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Upon arrival inspected system and found multiple critical errors and multiple other errors. Upon further inspection found AXB board will not communicate. As well as thermostat. Homeowners informed me they removed stat from the wall and replaced it trying to restart system and after that stat got hot and went blank. Communication error present for AXB and thermostat. Install t4 stat and start system under emergency auxiliary heat. Allowing system to operate under emergency functions until system can be further inspected and repaired or replaced due to repair costs.


Nate G.

Nate G. Job Checkin

Waterfurnace 5 series Closed pressurized loop Communicating thermostat throwing a communication fault Plugged Aid tool into diag port Aid tool throwing comm fault Reset power to geo System operating normally Most likely cause is a failing control board Ordered board Will return asap when we receive the board

Waterfurnace 5 series
Closed pressurized loop
Communicating thermostat throwing a communication fault 
Plugged Aid tool into diag port
Aid tool throwing comm fault
Reset power to geo
System operating normally
Most likely cause is a failing control board
Ordered board
Will return asap when we receive the board Waterfurnace 5 series
Closed pressurized loop
Communicating thermostat throwing a communication fault 
Plugged Aid tool into diag port
Aid tool throwing comm fault
Reset power to geo
System operating normally
Most likely cause is a failing control board
Ordered board
Will return asap when we receive the board

Nate G.

Nate G. Job Checkin

Diagnosed no water flow from well pump Well pump pulls 20A for a few seconds and drops to 0 Appears to be a locked up pump

Diagnosed no water flow from well pump
Well pump pulls 20A for a few seconds and drops to 0
Appears to be a locked up pump Diagnosed no water flow from well pump
Well pump pulls 20A for a few seconds and drops to 0
Appears to be a locked up pump

Graham M.

Graham M. Job Checkin

Upon arrival, inspected system and tested performance and found the system was only heating house with heat pumped by approximately 15° after inspecting airflow, found it on medium heat speed adjusted speed on high allowing approximately 1200 CFM for system. After adjustments, Delta T had rise by approximately 6°. Checked refrigerant pressures and found no major concerns having 388 on liquid and 128 on suction. Will need a return visit to compare numbers.


Nate G.

Nate G. Job Checkin

Performed heating maintenance on 7 Daikin gas furnaces, one Bryant electric air handler, two Reznor hanging unit heaters, and one Daikin mini split heat pump Replaced all 7 aprilaire 210 filters, replaced HEPA filters and UV bulb for the master bedroom attic system Ordering additional HEPA system maintenance kits and will return to replace all of those In-law suite furnace shows signs of condensation forming in the furnace intake pipe... discussed with Joe about installing a drain fitting to prevent water damage We will install this when we return for the HEPA maintenance Cleaned flame sensors on all furnaces Tested humidifiers and verified no water leaks Verified proper condensate drainage for all 96% efficient furnaces All blower wheels are clean Run tested all heating systems Checked fault code histories Garage heaters: inspected heat exchangers for cracks Cleaned flame sensors Tested operation

Performed heating maintenance on 7 Daikin gas furnaces, one Bryant electric air handler, two Reznor hanging unit heaters, and one Daikin mini split heat pump

Replaced all 7 aprilaire 210 filters, replaced HEPA filters and UV bulb for the master bedroom attic system
Ordering additional HEPA system maintenance kits and will return to replace all of those
In-law suite furnace shows signs of condensation forming in the furnace intake pipe... discussed with Joe about installing a drain fitting to prevent water damage
We will install this when we return for the HEPA maintenance 
Cleaned flame sensors on all furnaces
Tested humidifiers and verified no water leaks
Verified proper condensate drainage for all 96% efficient furnaces
All blower wheels are clean
Run tested all heating systems
Checked fault code histories
Garage heaters: inspected heat exchangers for cracks
Cleaned flame sensors
Tested operation Performed heating maintenance on 7 Daikin gas furnaces, one Bryant electric air handler, two Reznor hanging unit heaters, and one Daikin mini split heat pump

Replaced all 7 aprilaire 210 filters, replaced HEPA filters and UV bulb for the master bedroom attic system
Ordering additional HEPA system maintenance kits and will return to replace all of those
In-law suite furnace shows signs of condensation forming in the furnace intake pipe... discussed with Joe about installing a drain fitting to prevent water damage
We will install this when we return for the HEPA maintenance 
Cleaned flame sensors on all furnaces
Tested humidifiers and verified no water leaks
Verified proper condensate drainage for all 96% efficient furnaces
All blower wheels are clean
Run tested all heating systems
Checked fault code histories
Garage heaters: inspected heat exchangers for cracks
Cleaned flame sensors
Tested operation

Graham M.

Graham M. Job Checkin

Electric Heating preventative maintenance performed Turn heat on at thermostat Check filter: 20x20x1 due asap Inspect heating elements: no concerns Blower motor cap: n/a board controlled variable speed Temp rise at — for emergency heat Force defrost on outdoor unit reversing valve is operational Furnace and heat pump in optimal running conditions


Graham M.

Graham M. Job Checkin

Upon arrival inspected furnace and was not finding major concerns. Heat exchanger showed no signs of cracks, but combustion numbers were dangerously high at 400ppm COAF heat exchanger has failed and needs replaced or system entirely needs replaced. Recommend replacement consultation. Ac unit is operational and advised homeowner of new refrigerant and risks of 410. Recommended to stay with old refrigerant for as long as it keeps up unless quote accommodates otherwise.

Upon arrival inspected furnace and was not finding major concerns. Heat exchanger showed no signs of cracks, but combustion numbers were dangerously high at 400ppm COAF heat exchanger has failed and needs replaced or system entirely needs replaced. Recommend replacement consultation. Ac unit is operational and advised homeowner of new refrigerant and risks of 410. Recommended to stay with old refrigerant for as long as it keeps up unless quote accommodates otherwise. Upon arrival inspected furnace and was not finding major concerns. Heat exchanger showed no signs of cracks, but combustion numbers were dangerously high at 400ppm COAF heat exchanger has failed and needs replaced or system entirely needs replaced. Recommend replacement consultation. Ac unit is operational and advised homeowner of new refrigerant and risks of 410. Recommended to stay with old refrigerant for as long as it keeps up unless quote accommodates otherwise.

Brandon P.

Brandon P. Job Checkin

Perform preventative maintenence inspection on 2022 Carrier high efficiency furnace paired with Waterfurnace 5 Series split system. 20x25x4 air filter in new condition and on schedule with Steve. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode first and second stage. Confirmed gas pressures are within specifications. Temperature rise is within specifications. Blower and inducer motors tested good. 2" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. Run test unit in geothermal heating aswell. Did not check refrigerant as there are no issues suspected. Only code history present in the waterfurnace were system resets for power going out. All systems test were measuring within specifications. Units are operating properly, efficiently and ready for Winter. Inspected water heater for leak. Leakage on external of the tank is easily visible, but unable to pinpoint a lea

Perform preventative maintenence inspection on 2022 Carrier high efficiency furnace paired with Waterfurnace 5 Series split system. 20x25x4 air filter in new condition and on schedule with Steve. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode first and second stage. Confirmed gas pressures are within specifications. Temperature rise is within specifications. Blower and inducer motors tested good. 2" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. Run test unit in geothermal heating aswell. Did not check refrigerant as there are no issues suspected. Only code history present in the waterfurnace were system resets for power going out. All systems test were measuring within specifications. Units are operating properly, efficiently and ready for Winter. 

Inspected water heater for leak. Leakage on external of the tank is easily visible, but unable to pinpoint a lea Perform preventative maintenence inspection on 2022 Carrier high efficiency furnace paired with Waterfurnace 5 Series split system. 20x25x4 air filter in new condition and on schedule with Steve. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode first and second stage. Confirmed gas pressures are within specifications. Temperature rise is within specifications. Blower and inducer motors tested good. 2" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. Run test unit in geothermal heating aswell. Did not check refrigerant as there are no issues suspected. Only code history present in the waterfurnace were system resets for power going out. All systems test were measuring within specifications. Units are operating properly, efficiently and ready for Winter. 

Inspected water heater for leak. Leakage on external of the tank is easily visible, but unable to pinpoint a lea

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Trane S9V2 high efficiency furnace. 16x25x4 air filter is in new condition and on schedule with Max. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode from thermostat. Temperature rise is within specs. Manifold pressure is within spec. Blower motor and inducer motor running within spec. 2" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. Furnace is operating properly, efficiently and ready for Winter.