725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews

Rated 4.9 out of 5 stars based on 345 customer reviews

Excellent Service by Gregg and his colleague

Greg and his colleague did awesome job balancing and providing recommendations. He also uncovered an issue that was kind a hidden.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

We have used Weston air on several properties and the service is always professional and mechanically well done. The price is fair. What we like is that it’s very realizable,

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding Company!

We have been a customer of Westin Air for four years now and recently had our old HVAC system replaced by Westin Air. They are the most professional HVAC company we’ve ever had with outstanding service and technical excellent. When I had a question about a new sound from our new system when turning on the furnace, Wes the owner personally came to the house to check it out (the sound was normal to the new system). What service! If you have any HVAC needs, call Westin Air.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Chris was great

Showed up in a timely manner and explained everything very well

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Attention to detail

Chris has a great attention to detail and is always willing to help us with our Energy Star Program

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Quality personnel

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service Professional employees!

Very responsive and gets the job done!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Service man showed up on time. Found part to be replaced and explained the problem. Also, gave us an overall status of the unit.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great communication

Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick Response & Excellent Service!

Westin Air continues to exceed my expectations for responsiveness and quality of service! Everyone is extremely friendly, understand and accommodating to help make the situation right! I would highly recommend Westin Air to anyone who wants a reliable, friendly and HONEST HVAC company!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and quick response!

Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Experience!

Chris was Amazing!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

A professional in your own neighborhood

I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs

  • Overall Experience
  • Quality
  • Price
  • Convenience

Takes Pride

Chris takes pride in his works and cares about things getting done properly!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Graham M.

Graham M. Job Checkin

Unit had a dirty flame sensor. Clean sensor and verify proper operation. Intake pipe needs a condensation trap to prevent future issues. Pipe is allowing in lots of moisture


Graham M.

Graham M. Job Checkin

Upon arrival inspected unit and found igniter non operational. Ohmed out at OL broken circuit. Replace igniter with glow fly and test run system, system started up and began heating no problem.


Nate G.

Nate G. Job Checkin

Performed heating maintenance on a 2022 Lennox 96% efficient single stage natural gas furnace Replaced aprilaire 35 water panel for the humidifier Tightened water line on the outlet of the solenoid to stop a small leak Pulled condensate lines and cleared debris that was causing a water backup into the inducer housing Tightened clamp on inducer outlet coupling to stop a water leak Pulled burner door off and inspected burners Removed flame sensor and cleaned 20x25x4 filter is good Blower wheel is dirty with drywall dust from new construction Recommend cleaning the blower wheel Run tested furnace Adjusted gas pressure to 3.0"wc. and increased blower speed to high Temperature rise 67⁰ (spec is 45-75⁰) Humidifier working properly, no water leaks at this time Other than the dirty blower wheel, furnace is in good shape and operating properly at this time. Signed up for gold maintenance plan


Brandon P.

Brandon P. Job Checkin

Install replacement OEM Trane variable speed blower motor. Test run operation in fan only and geothermal heating stage 2 for multiple speed test.


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20xx25x1 washable filter new today Clean flame sensor Ohm test igniter: 65.3 Burners rusty and needed cleaned. New today with stainless steel Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: new today #35 owner supply Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 4.38 Check amp draw on inducer motor:0.91 Check delta T - 62° Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

After thermostat was replaced unit was stuck with only cooling from heat pump. Reversing valve got constant power while heating or cooling. After diagnosing thermostat and controls, found wiring from thermostat to furnace was shorted. Switched orange for stat to pink and problem was resolved.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Trane S9V2 furnace running in great condition. 20x25x4 air filter is new today. Tested operation of I-Wave air cleaner. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Humidifier pad is new today. Humidistat set to 35%. Test run furnace in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. 3" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. Tested operation of humidifier during heating test. All systems are operating properly, efficiently and ready for Winter.


Nate G.

Nate G. Job Checkin

Discussed issue over the phone. Everything he's describing is a setting issue with the thermostat. He will play with the settings and call us back Monday if needed.


Nate G.

Nate G. Job Checkin

Performed heating maintenance on a 2022 Lennox 2 stage 96% efficient propane furnace Replaced 20x25x1 Filter Pulled and cleaned the flame sensor Checked Condensate lines and ports for blockage Run tested furnace Low fire gas pressure set to 4.5"wc (spec 4.5) Temperature rise 38⁰ (spec 30-60) High fire gas pressure 10"wc (spec 10") Temperature rise 50⁰ (spec 40-70) No signs of water leaks inside the furnace No water leaks from the intake and exhaust vent piping Blower wheel is clean Inducer and blower motors amp draw in spec Furnace is in perfect running order and condition

Performed heating maintenance on a 2022 Lennox 2 stage 96% efficient propane furnace
Replaced 20x25x1 Filter
Pulled and cleaned the flame sensor
Checked Condensate lines and ports for blockage
Run tested furnace
Low fire gas pressure set to 4.5"wc (spec 4.5) 
Temperature rise 38⁰ (spec 30-60)
High fire gas pressure 10"wc (spec 10")
Temperature rise 50⁰ (spec 40-70)
No signs of water leaks inside the furnace
No water leaks from the intake and exhaust vent piping
Blower wheel is clean
Inducer and blower motors amp draw in spec
Furnace is in perfect running order and condition

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on 2021 Bryant high efficiency furnace running in great condition. 20x25x4 air filter in new condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Test run in heating mode from thermostat. Temperature rise is within specs. Manifold gas pressure is within spec. Blower motor and inducer motor running within spec. 2" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x4 new today Clean flame sensor Ohm test igniter: 54.6 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: new today #35 water open air open Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.2 Check amp draw on inducer motor:0.87 Check delta T - 42° Furnace is in optimal running conditions


Nate G.

Nate G. Job Checkin

Performed two system heating maintenance Second floor system: 2018 Goodman 2 stage 96% efficient natural gas furnace 16x25x4 filter is OK Installed intake drain to stop further water damage to the gas valve Corrected water leak issue at the inducer outlet hose clamp Pulled and cleaned flame sensor Condensate trap is clear Run tested furnace High fire was set to 4"wc, adjusted down to specification 3.5" Temperature rise 40⁰ Low fire gas pressure was 2.5"wc, adjusted down to specification 1.7" Temperature rise 35⁰ First floor system 2018 Goodman 2 stage 96% efficient natural gas furnace Installed intake drain coupling, condensation damage to gas valve Pulled and cleaned flame sensor Drain trap clear 16x25x4 filter OK Replaced humidifier water panel High fire set to 3.5" 50⁰ temp rise Low fire set to 1.9"

Performed two system heating maintenance

Second floor system:
2018 Goodman 2 stage 96% efficient natural gas furnace 
16x25x4 filter is OK
Installed intake drain to stop further water damage to the gas valve
Corrected water leak issue at the inducer outlet hose clamp
Pulled and cleaned flame sensor 
Condensate trap is clear
Run tested furnace
High fire was set to 4"wc, adjusted down to specification 3.5"
Temperature rise 40⁰
Low fire gas pressure was 2.5"wc, adjusted down to specification 1.7"
Temperature rise 35⁰

First floor system 
2018 Goodman 2 stage 96% efficient natural gas furnace
Installed intake drain coupling, condensation damage to gas valve
Pulled and cleaned flame sensor
Drain trap clear 
16x25x4 filter OK
Replaced humidifier water panel
High fire set to 3.5" 50⁰ temp rise
Low fire set to 1.9" 
Performed two system heating maintenance

Second floor system:
2018 Goodman 2 stage 96% efficient natural gas furnace 
16x25x4 filter is OK
Installed intake drain to stop further water damage to the gas valve
Corrected water leak issue at the inducer outlet hose clamp
Pulled and cleaned flame sensor 
Condensate trap is clear
Run tested furnace
High fire was set to 4"wc, adjusted down to specification 3.5"
Temperature rise 40⁰
Low fire gas pressure was 2.5"wc, adjusted down to specification 1.7"
Temperature rise 35⁰

First floor system 
2018 Goodman 2 stage 96% efficient natural gas furnace
Installed intake drain coupling, condensation damage to gas valve
Pulled and cleaned flame sensor
Drain trap clear 
16x25x4 filter OK
Replaced humidifier water panel
High fire set to 3.5" 50⁰ temp rise
Low fire set to 1.9"

Jason D.

Jason D. Job Checkin

Per Geno, PO-561JV-117 - VPO - Furnace Filters Chris Meyer dropped off 4 filters.


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 16x25x4 clean 10/25 Clean flame sensor Ohm test igniter: 56.8 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.21 Check amp draw on inducer motor:1.26 Check delta T - 56° Furnace is in optimal running conditions


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Trane XT80 furnace running in great condition. Trane Clean Effects filter cleaning. Clean flame sensor and check ignitor. Visual inspection of burners. Test ran in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. 4" galvanized B-vent in good condition and no sign of leaks. 0PPM CO detected during testing. Furnace is operating properly, efficiently and ready for Winter.