Rated 4.9 out of 5 stars based on 345 customer reviews

Excellent Service by Gregg and his colleague

Greg and his colleague did awesome job balancing and providing recommendations. He also uncovered an issue that was kind a hidden.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

We have used Weston air on several properties and the service is always professional and mechanically well done. The price is fair. What we like is that it’s very realizable,

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding Company!

We have been a customer of Westin Air for four years now and recently had our old HVAC system replaced by Westin Air. They are the most professional HVAC company we’ve ever had with outstanding service and technical excellent. When I had a question about a new sound from our new system when turning on the furnace, Wes the owner personally came to the house to check it out (the sound was normal to the new system). What service! If you have any HVAC needs, call Westin Air.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Chris was great

Showed up in a timely manner and explained everything very well

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Attention to detail

Chris has a great attention to detail and is always willing to help us with our Energy Star Program

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Quality personnel

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service Professional employees!

Very responsive and gets the job done!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Service man showed up on time. Found part to be replaced and explained the problem. Also, gave us an overall status of the unit.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great communication

Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick Response & Excellent Service!

Westin Air continues to exceed my expectations for responsiveness and quality of service! Everyone is extremely friendly, understand and accommodating to help make the situation right! I would highly recommend Westin Air to anyone who wants a reliable, friendly and HONEST HVAC company!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and quick response!

Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Experience!

Chris was Amazing!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

A professional in your own neighborhood

I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs

  • Overall Experience
  • Quality
  • Price
  • Convenience

Takes Pride

Chris takes pride in his works and cares about things getting done properly!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Carrier high efficiency furnace running in great condition. 20x25x4 air filter is new today. #35 humidifier pad in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Humidifier tested during heating mode. Dehumidifier is disabled for Winter time. Furnace and humidifier are operating properly, efficiently and ready for Winter.


Nate G.

Nate G. Job Checkin

Geothermal had 155 occurrences of FP1 fault Last lockout was FP1 With aurora aid tool, monitored fp1 During start up, it went down to -11 and came back up in a short enough period of time to not trigger the fault Checked wiring of fp1, no issues found Used temperature clamp on TXV outlet to compare to fp1 numbers, fp1 was fluctuating a lot while the actual temperature of the line remained steady. Also found high pressure switch Bypassed Verified it is stuck open We will send a quote to replace fp1 sensor and install a service port tee with a high pressure switch

Geothermal had 155 occurrences of FP1 fault
Last lockout was FP1
With aurora aid tool, monitored fp1 
During start up, it went down to -11 and came back up in a short enough period of time to not trigger the fault
Checked wiring of fp1, no issues found
Used temperature clamp on TXV outlet to compare to fp1 numbers, fp1 was fluctuating a lot while the actual temperature of the line remained steady.
Also found high pressure switch Bypassed 
Verified it is stuck open

We will send a quote to replace fp1 sensor and install a service port tee with a high pressure switch

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Bryant high efficiency furnace running in great condition. 16x25x1 air filter in new condition. #35 humidifier pad in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Humidifier tested during heating mode test. System is operating properly, efficiently and ready for Winter.


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x4 new today truck stock 1 on site Clean flame sensor - minor oxidation Inspect burners - clean no concerns Ohm test igniter: 53.1 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.25 Check amp draw on inducer motor:0.42 Check delta T - 55° Furnace is in optimal running conditions

Gas heating preventative maintenance performed
Check filter - 20x25x4 new today truck stock 1 on site 
Clean flame sensor - minor oxidation 
Inspect burners - clean no concerns
Ohm test igniter: 53.1
Inspect wiring for loose connections and/or hot spots - none found
Check humidifier pad: n/a
Inspect exhaust flu - no concerns
Set thermostat for heat
Check amp draw on blower motor: 3.25
Check amp draw on inducer motor:0.42
Check delta T -  55°
Furnace is in optimal running conditions

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Trane S9V2 high efficiency furnace running in great condition. 20x25x4 air filter in new condition. #35 humidifier pad in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Humidifier tested during heating mode test. Furnace is operating properly, efficiently and ready for Winter.


Graham M.

Graham M. Job Checkin

Heat pump preventative maintenance performed Turn heat on at thermostat Check filter: 16x20x1 new today Inspect heating elements and wiring: no concerns Blower motor cap: n/a ECM Temp rise at — 56° Force defrost on outdoor unit reversing valve is operational Air handler and heat pump in optimal running conditions


Nate G.

Nate G. Job Checkin

2013 ICP 80% single stage furnace 16x25x1 filter needs replaced Cleaned flame sensor Adjusted gas pressure to 3.2" WC Inducer motor bearings beginning to fail Recommend replacing inducer motor before it completely stops, leaving the furnace inoperable Vent piping in good shape Blower wheel is a little dirty, but not causing operational issues with heat Burners are in good shape No gas leaks detected Furnace is operating within factory specs at this time

2013 ICP 80% single stage furnace
16x25x1 filter needs replaced
Cleaned flame sensor
Adjusted gas pressure to 3.2" WC
Inducer motor bearings beginning to fail
Recommend replacing inducer motor before it completely stops, leaving the furnace inoperable 
Vent piping in good shape 
Blower wheel is a little dirty, but not causing operational issues with heat
Burners are in good shape 
No gas leaks detected
Furnace is operating within factory specs at this time

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Trane Tam9 air handler unit running in great condition. 20x22x1 air filter in new condition. Inspect blower and electric heat stip compartments for any loose or damaged wiring and components. None found. Test ran operation of electric heating strips and heat pump heating. Electric heat strips are operating properly and within Amp draw specifications. Heat pump heating tested by non-invasive refrigerant test by testing refrigerant line temperature. Temperatures are within spec based on outdoor temperature. No issues found or suspected at this time. System is operating properly, efficiently and ready for Winter.


Graham M.

Graham M. Job Checkin

Upon arrival inspected system and found no major concerns. Listened for noise once in attic and couldn’t recreate noise they were getting. It is only when the furnace is running it was rattling was the information I was given, couldn’t get any noises from unit. Moved a large rodent trap to get to furnace, suspect the rodent trap was rattling because it engaged as soon as I bumped it. Informed homeowner to call us back if noise continues but cannot recreate noise at this time.


Nate G.

Nate G. Job Checkin

Furnace locked out for 3 hours on high temperature limit Reset power, jumped out thermostat to run heat and bypass the time delay from power reset Furnace came on normally Set gas pressure to 3.0" Let Furnace run a while until confident the limit wasn't going to trip Pulled jumpers off (thermostat calling for heat at the same time), blower motor stopped while everything else continues to run This explains limit trips Found common wire for blower loose Tried to duplicate fault Furnace continued to run property after securing blower wire


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x1 Clean flame sensor Inspect burners - clean no concerns Ohm test igniter: 58.6 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 5.3 Check amp draw on inducer motor:1.58 Check delta T - 59° Furnace is in optimal running conditions


Nate G.

Nate G. Job Checkin

Performed heating maintenance Aprilaire 213 does not need replaced yet Aprilaire 35 water panel does not need replaced, either Humidifier working properly with no water leaks present at this time Bypass damper is open Pulled condensate trap and flushed with hot water... lots of debris came out Pulled flame sensor and cleaned Blower is clean Burners are clean Cleared debris from intake screen Set gas pressure with reference to the sealed burner box: 3.5/1.7 Furnace is in good shape Operating within factory specs at this time


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Tempstar high efficiency furnace running in great condition. 20x25x4 air filter in decent condition. Check again in 1-2 months. Humidifier pad in new condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Reprogrammed and confirmed proper wiring of thernostat and humidifier for increased operation allowance. Previously, humidifier would only run when heating is running. Programmed stat and confirmed proper wiring to allow humidifier to run whenever a call for humidity is present. Humidifier will now operate whenever it is needed. All systems for heating and humidification are operating properly. Claire also asked about owners manual literature for thermostat as there was none l


Nate G.

Nate G. Job Checkin

Performed heating maintenance 20x25x4 (use Honeywell brand) needs replaced Humidifier #35 water panel in good shape Bypass damper open Humidity set to 40% Tightened packing nut on water shutoff valve to stop a small drip Humidifier operating properly and no water leaks during operation Wired thermostat for 2 stage heat Adjusted furnace for no upstaging delay on a W2 call Pulled and cleaned burners **Gary wants to upgrade to stainless steel burners next heat maintenance** Cleaned flame sensor Trap is clear High fire gas pressure 3.5"wc, 52⁰ temperature rise Low fire gas pressure 1.7"WC 48⁰ Temperature rise Furnace is in good working order and operating within factory specs at this time.


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - Trane clean effects ok Clean flame sensor Inspect burners - pull and wire brush Ohm test igniter: 54.8 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 4.5 Check amp draw on inducer motor:0.24 Check delta T - 54° Furnace is in optimal running conditions