725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews

Rated 4.9 out of 5 stars based on 345 customer reviews

Excellent Service by Gregg and his colleague

Greg and his colleague did awesome job balancing and providing recommendations. He also uncovered an issue that was kind a hidden.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

We have used Weston air on several properties and the service is always professional and mechanically well done. The price is fair. What we like is that it’s very realizable,

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding Company!

We have been a customer of Westin Air for four years now and recently had our old HVAC system replaced by Westin Air. They are the most professional HVAC company we’ve ever had with outstanding service and technical excellent. When I had a question about a new sound from our new system when turning on the furnace, Wes the owner personally came to the house to check it out (the sound was normal to the new system). What service! If you have any HVAC needs, call Westin Air.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Chris was great

Showed up in a timely manner and explained everything very well

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Attention to detail

Chris has a great attention to detail and is always willing to help us with our Energy Star Program

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Quality personnel

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service Professional employees!

Very responsive and gets the job done!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Service man showed up on time. Found part to be replaced and explained the problem. Also, gave us an overall status of the unit.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great communication

Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick Response & Excellent Service!

Westin Air continues to exceed my expectations for responsiveness and quality of service! Everyone is extremely friendly, understand and accommodating to help make the situation right! I would highly recommend Westin Air to anyone who wants a reliable, friendly and HONEST HVAC company!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and quick response!

Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Experience!

Chris was Amazing!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

A professional in your own neighborhood

I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs

  • Overall Experience
  • Quality
  • Price
  • Convenience

Takes Pride

Chris takes pride in his works and cares about things getting done properly!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Brandon P.

Brandon P. Job Checkin

Upon arrival, there is a wet spot below the humidifier. Inspect internal cabinet of the geothermal unit and see no water. Remove humidifier door and there is water that has been sucked off the humidifier pad. Humidifier fan speed is set to high. Change fan speed to low and perform test run to check for a continued leak. With low fan setting, water is still being sucked off of the humidifier pad due to a dirty/clogged humidifier pad. Although only approximately 5 months of humidifier operation, excessive build up is most likely due to the humidifier being set to 60% humidity, aswell as the longer and colder winter we have had this year. Other contributions could be water quality aswell as air quality. A dirty humidifier pad is not the responsibility of Westin Air as it is a regular maintenance item. Although April air recommends changing it every 12 months, the above mentioned operating condition can necessitate changing the humidifier pad earlier than the 12 months.


Graham M.

Graham M. Job Checkin

Upon arrival inspected system and found no concerns with heating function. Inspected electric heating element wiring and camera over the elements and saw no concerns with elements units heating properly and no weird smells coming from unit while running. Start up heat pump and verify heating from heat pump, unit started heating at 24° delta T and was not making any burning smell. Advised homeowner hvac running properly and not showing concerns at this time.


Brandon P.

Brandon P. Job Checkin

Cancelled while en route


Graham M.

Graham M. Job Checkin

Replace 20x20x2 filters x4 Replace AX52 belt. Converted from Ax54 previously installed by Seth. Test run heat verify proper operation Clean flame sensor Inspect heat exchanger verify safe for operation.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on two high efficiency gas furnaces running in good condition. Replace both air filters. Humidifier pads are in decent condition. Recommend replacing before next heating season. Clean flame sensors and checked ignitors. Visual inspection of burners. Flush condensation traps and drain lines. Run test systems in heating mode. Both systems are operating properly and within specs for temperature rise, and blower and inducer motor amp draw. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Tested humidifier operation on both. Furnaces and humidifiers are operating properly, efficiently and ready for Winter.


Graham M.

Graham M. Job Checkin

Heat pump preventative maintenance performed Turn heat on at thermostat Check filter: 16x25x1 clean Inspect heating elements and wiring: no concerns Blower motor cap: 10mfd @ 8.3 new today Temp rise at — 38° heat pump Force defrost on outdoor unit reversing valve is operational Outdoor cap 45+5 @ 44.31+4.82 Air handler and heat pump in optimal running conditions


Nate G.

Nate G. Job Checkin

Blower motor blew the power resistor again Also found control board no longer outputting blower control from the 16-pin Installed evergreen VS 1HP motor and set it up for 24V input operation.


Brandon P.

Brandon P. Job Checkin

Performed an operation test on the Waterfurnace Legend unit to check for any out of specification measurements. Performed a heat of extraction worksheet to measure heating BTU output and efficiency. Heat of extraction shows that the system is outputting 31,525BTU/Hr. Waterfurnace specifications list the BTU/Hr output at 30F ground water temperature to be between 27,000 and 35,000 BTU/Hr. Compressor is running at 15A and is within specifications. Blower motor is running at 3A and is within specifications. Performed an operation test on emergency/auxiliary heating strips. Both heating strips are running at the proper 20A. Shut down heat stips to verify that the heat stips are not stuck on or shorted out. 0A reading when off. During operation test of geothermal, the only abnormal reading was the ground loop pressure. Ground loop pressure is currently at 20psi dormant. Ground loop pressure should be within 60-80PSI per Waterfurnace manufacturers recommended pressures. Low ground loop press

Performed an operation test on the Waterfurnace Legend unit to check for any out of specification measurements. Performed a heat of extraction worksheet to measure heating BTU output and efficiency. Heat of extraction shows that the system is outputting 31,525BTU/Hr. Waterfurnace specifications list the BTU/Hr output at 30F ground water temperature to be between 27,000 and 35,000 BTU/Hr. Compressor is running at 15A and is within specifications. Blower motor is running at 3A and is within specifications. Performed an operation test on emergency/auxiliary heating strips. Both heating strips are running at the proper 20A. Shut down heat stips to verify that the heat stips are not stuck on or shorted out. 0A reading when off. During operation test of geothermal, the only abnormal reading was the ground loop pressure. Ground loop pressure is currently at 20psi dormant. Ground loop pressure should be within 60-80PSI per Waterfurnace manufacturers recommended pressures. Low ground loop press Performed an operation test on the Waterfurnace Legend unit to check for any out of specification measurements. Performed a heat of extraction worksheet to measure heating BTU output and efficiency. Heat of extraction shows that the system is outputting 31,525BTU/Hr. Waterfurnace specifications list the BTU/Hr output at 30F ground water temperature to be between 27,000 and 35,000 BTU/Hr. Compressor is running at 15A and is within specifications. Blower motor is running at 3A and is within specifications. Performed an operation test on emergency/auxiliary heating strips. Both heating strips are running at the proper 20A. Shut down heat stips to verify that the heat stips are not stuck on or shorted out. 0A reading when off. During operation test of geothermal, the only abnormal reading was the ground loop pressure. Ground loop pressure is currently at 20psi dormant. Ground loop pressure should be within 60-80PSI per Waterfurnace manufacturers recommended pressures. Low ground loop press

Jason D.

Jason D. Job Checkin

SOLD: 02/24/2026 12:34:58 PM - Option 2 Install New Bryant Single Stage Gas Furnace Model #: 800SB36070M17A-B Serial #: 4525A16166 70,000 BTU’s - 80% AFUE Install Bradford White 50 Gal Water Heater Heater Model #: RG250T6N Serial# BD55088098 Installation: * Reconnect to existing gas line and high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system * Chimney Liner * Duct Work - Replace Return Air Drop * Honeywell P200 Thermostat * Air Filtration - AprilAire 1210 (20X25) Media Air Cleaner Warranty: 20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)


SOLD: 02/24/2026 12:34:58 PM - Option 2

Install New Bryant Single Stage Gas Furnace
Model #:  800SB36070M17A-B
Serial #: 4525A16166
70,000 BTU’s - 80% AFUE

Install Bradford White 50 Gal Water Heater
Heater Model #: RG250T6N Serial# BD55088098

 Installation:
* Reconnect to existing gas line and high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* Chimney Liner
* Duct Work - Replace Return Air Drop
* Honeywell P200 Thermostat
* Air Filtration - AprilAire 1210 (20X25) Media Air Cleaner
 
Warranty:
20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

SOLD: 02/24/2026 12:34:58 PM - Option 2

Install New Bryant Single Stage Gas Furnace
Model #:  800SB36070M17A-B
Serial #: 4525A16166
70,000 BTU’s - 80% AFUE

Install Bradford White 50 Gal Water Heater
Heater Model #: RG250T6N Serial# BD55088098

 Installation:
* Reconnect to existing gas line and high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* Chimney Liner
* Duct Work - Replace Return Air Drop
* Honeywell P200 Thermostat
* Air Filtration - AprilAire 1210 (20X25) Media Air Cleaner
 
Warranty:
20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x1 new today Clean flame sensor Inspect burners - no concerns Ohm test igniter: 47.3 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - 3”/5”/7” Y for flue forming holes as well as 5” 90° and 3” straight pipe section. Set thermostat for heat Check amp draw on blower motor: 3.45 Check amp draw on inducer motor:0.36 Check delta T - 56° Furnace is in optimal running conditions Built estimate for flue repairs if interested.

Gas heating preventative maintenance performed
Check filter - 20x25x1 new today 
Clean flame sensor
Inspect burners - no concerns
Ohm test igniter: 47.3
Inspect wiring for loose connections and/or hot spots - none found
Check humidifier pad: n/a
Inspect exhaust flu - 3”/5”/7” Y for flue forming holes as well as 5” 90° and 3” straight pipe section.  
Set thermostat for heat
Check amp draw on blower motor: 3.45
Check amp draw on inducer motor:0.36
Check delta T -  56°
Furnace is in optimal running conditions
 
Built estimate for flue repairs if interested. Gas heating preventative maintenance performed
Check filter - 20x25x1 new today 
Clean flame sensor
Inspect burners - no concerns
Ohm test igniter: 47.3
Inspect wiring for loose connections and/or hot spots - none found
Check humidifier pad: n/a
Inspect exhaust flu - 3”/5”/7” Y for flue forming holes as well as 5” 90° and 3” straight pipe section.  
Set thermostat for heat
Check amp draw on blower motor: 3.45
Check amp draw on inducer motor:0.36
Check delta T -  56°
Furnace is in optimal running conditions
 
Built estimate for flue repairs if interested.

Nate G.

Nate G. Job Checkin

Replace heat exchanger under factory parts warranty


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - December Clean flame sensor Inspect burners - clean Ohm test igniter: 63.2 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 5.30 Check amp draw on inducer motor:0.82 Check delta T - 57° Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Install humidifier, run drain for humidifier and water supply. Wire into furnace control so unit runs with furnace while humidity demand is present from humidistat. Ecobee could not run the humidifier

Install humidifier, run drain for humidifier and water supply. Wire into furnace control so unit runs with furnace while humidity demand is present from humidistat. Ecobee could not run the humidifier Install humidifier, run drain for humidifier and water supply. Wire into furnace control so unit runs with furnace while humidity demand is present from humidistat. Ecobee could not run the humidifier

Brandon P.

Brandon P. Job Checkin

Replace failing inducer motor. Reuse original mounting brackets. Replace all gaskets and dampeners. Test run operation of heating mode.


Nate G.

Nate G. Job Checkin

Moved generator powered circuit to the first bank of auxiliary heat 20kw about stalled the generator Cannot separate the heater circuits to prevent that from happening He understands needing to run the heat with next to nothing else running while on generator.