725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews

Rated 4.9 out of 5 stars based on 345 customer reviews

Excellent Service by Gregg and his colleague

Greg and his colleague did awesome job balancing and providing recommendations. He also uncovered an issue that was kind a hidden.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

We have used Weston air on several properties and the service is always professional and mechanically well done. The price is fair. What we like is that it’s very realizable,

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding Company!

We have been a customer of Westin Air for four years now and recently had our old HVAC system replaced by Westin Air. They are the most professional HVAC company we’ve ever had with outstanding service and technical excellent. When I had a question about a new sound from our new system when turning on the furnace, Wes the owner personally came to the house to check it out (the sound was normal to the new system). What service! If you have any HVAC needs, call Westin Air.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Chris was great

Showed up in a timely manner and explained everything very well

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Attention to detail

Chris has a great attention to detail and is always willing to help us with our Energy Star Program

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Quality personnel

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service Professional employees!

Very responsive and gets the job done!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Service man showed up on time. Found part to be replaced and explained the problem. Also, gave us an overall status of the unit.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great communication

Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick Response & Excellent Service!

Westin Air continues to exceed my expectations for responsiveness and quality of service! Everyone is extremely friendly, understand and accommodating to help make the situation right! I would highly recommend Westin Air to anyone who wants a reliable, friendly and HONEST HVAC company!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and quick response!

Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Experience!

Chris was Amazing!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

A professional in your own neighborhood

I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs

  • Overall Experience
  • Quality
  • Price
  • Convenience

Takes Pride

Chris takes pride in his works and cares about things getting done properly!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Nate G.

Nate G. Job Checkin

Performed heating maintenance on a 2022 Bryant 95% efficient single stage natural gas furnace Replaced replaced the electronic air cleaner filter cartridge with the one we provide with the gold maintenance plan PGAPXCAR 20X20 Aprilaire 500 humidifier #10 water panel in good shape Bypass damper moved to open (winter) positiom Run tested humidifier to verify correct operation and no water leaks at this time Humidity set to 45% ***Decrease humidity setting if condensation forms on any windows, especially with cold outdoor temperatures** Pulled flame sensor and cleaned Condensate trap is clear Blower wheel in OK condition Burner Manifold gas pressure set to 3.0"wc Temperature rise stabilized @ 53⁰F (spec 40-70⁰) Furnace is operating within factory specifications at this time No concerns found on today's visit

Performed heating maintenance on a 2022 Bryant 95% efficient single stage natural gas furnace
Replaced replaced the electronic air cleaner filter cartridge with the one we provide with the gold maintenance plan 
PGAPXCAR 20X20
Aprilaire 500 humidifier #10 water panel in good shape
Bypass damper moved to open (winter) positiom
Run tested humidifier to verify correct operation and no water leaks at this time 
Humidity set to 45%
***Decrease humidity setting if condensation forms on any windows, especially with cold outdoor temperatures**
Pulled flame sensor and cleaned 
Condensate trap is clear
Blower wheel in OK condition 
Burner Manifold gas pressure set to 3.0"wc
Temperature rise stabilized @ 53⁰F (spec 40-70⁰)
Furnace is operating within factory specifications at this time 
No concerns found on today's visit Performed heating maintenance on a 2022 Bryant 95% efficient single stage natural gas furnace
Replaced replaced the electronic air cleaner filter cartridge with the one we provide with the gold maintenance plan 
PGAPXCAR 20X20
Aprilaire 500 humidifier #10 water panel in good shape
Bypass damper moved to open (winter) positiom
Run tested humidifier to verify correct operation and no water leaks at this time 
Humidity set to 45%
***Decrease humidity setting if condensation forms on any windows, especially with cold outdoor temperatures**
Pulled flame sensor and cleaned 
Condensate trap is clear
Blower wheel in OK condition 
Burner Manifold gas pressure set to 3.0"wc
Temperature rise stabilized @ 53⁰F (spec 40-70⁰)
Furnace is operating within factory specifications at this time 
No concerns found on today's visit

Nate G.

Nate G. Job Checkin

Diagnostic on 4 RTU systems Rtu11 smoke detector going into alarm Removed detector and blew out, system still green now That enunciator for 11 needs new wire pulled to it Electrician said they'd get it Rtu12 smoke detector no power Needs wired into the unit on the roof Jim approved repairs Pull wire inside the unit and connect. Rtu13&14 both have failed transformers Jim approved replacing the failed transformers.


Graham M.

Graham M. Job Checkin

Perform heating maintenance on 3 geothermal systems. Force each unit into stage 12 high heat and verify proper operation parameters. Humidifier water panels not due yet left 5 behind for whole house 2 for mother suite and 3 main house. Humidifiers don’t get much use because of geothermal heat not being super dry to begin with. All three geothermal units operating within manufacture parameters. Aid tool breakdown submitted to file

Perform heating maintenance on 3 geothermal systems. Force each unit into stage 12 high heat and verify proper operation parameters. Humidifier water panels not due yet left 5 behind for whole house 2 for mother suite and 3 main house. Humidifiers don’t get much use because of geothermal heat not being super dry to begin with. All three geothermal units operating within manufacture parameters. Aid tool breakdown submitted to file Perform heating maintenance on 3 geothermal systems. Force each unit into stage 12 high heat and verify proper operation parameters. Humidifier water panels not due yet left 5 behind for whole house 2 for mother suite and 3 main house. Humidifiers don’t get much use because of geothermal heat not being super dry to begin with. All three geothermal units operating within manufacture parameters. Aid tool breakdown submitted to file

Graham M.

Graham M. Job Checkin

Inspect each Waterfurnace system, start each system up with aid tool and test on max speed 12 verifying proper operation at full capacity. All filters replaced 11/6/25 3 “#35 water panels” sold on visit third humidifier hiding on back side of unit. Geo 2 & 3 showing no signs of concern with proper operation parameters and good heat of extraction. Geo 1 in center of house has multiple error codes for e72 suction temp sensor error. Inspected sensors and no concerns with sensors. When flipping sensors had issue post with -112 on suction with both sensors. EEV control has internal failure causing it to not work properly at all times e72 posted 570 times during operation. Desert air system is becoming filthy from fresh air allowing in dirt and bugs that have built up over the years of runtime. Suggest installing custom filtration for fresh air and performing deep cleaning on air coil to remove the bug/dust/dirt debris. Box measures 6”x22” for fresh air with a 6” round supplying it.

Inspect each Waterfurnace system, start each system up with aid tool and test on max speed 12 verifying proper operation at full capacity. 

All filters replaced 11/6/25
3 “#35 water panels” sold on visit third humidifier hiding on back side of unit. 

Geo 2 & 3 showing no signs of concern with proper operation parameters and good heat of extraction. 

Geo 1 in center of house has multiple error codes for e72 suction temp sensor error. Inspected sensors and no concerns with sensors. When flipping sensors had issue post with -112 on suction with both sensors. EEV control has internal failure causing it to not work properly at all times e72 posted 570 times during operation. 

Desert air system is becoming filthy from fresh air allowing in dirt and bugs that have built up over the years of runtime. Suggest installing custom filtration for fresh air and performing deep cleaning on air coil to remove the bug/dust/dirt debris. Box measures 6”x22” for fresh air with a 6” round supplying it. Inspect each Waterfurnace system, start each system up with aid tool and test on max speed 12 verifying proper operation at full capacity. 

All filters replaced 11/6/25
3 “#35 water panels” sold on visit third humidifier hiding on back side of unit. 

Geo 2 & 3 showing no signs of concern with proper operation parameters and good heat of extraction. 

Geo 1 in center of house has multiple error codes for e72 suction temp sensor error. Inspected sensors and no concerns with sensors. When flipping sensors had issue post with -112 on suction with both sensors. EEV control has internal failure causing it to not work properly at all times e72 posted 570 times during operation. 

Desert air system is becoming filthy from fresh air allowing in dirt and bugs that have built up over the years of runtime. Suggest installing custom filtration for fresh air and performing deep cleaning on air coil to remove the bug/dust/dirt debris. Box measures 6”x22” for fresh air with a 6” round supplying it.

Nate G.

Nate G. Job Checkin

Performed heating maintenance on a 2022 Daikin Fit 17SEER heat pump system Replaced Honeywell 20x25x4 filter with one we provide with the gold maintenance plan Tested aprilaire 600 humidifier Water panel in good shape, operating normally, no water leaks at this time Tested NuCalgon iWave ionizer, self test was successful Blower is in OK condition Inspected auxiliary heat kit for overheated wiring All connections are in good shape Run tested heating Witnessed system perform defrost successfully After ten minutes of run time, temperature rise was 30⁰, vapor line 141⁰, BTU capacity calculat4d to 42000btu No concerns found

Performed heating maintenance on a 2022 Daikin Fit 17SEER heat pump system
Replaced Honeywell 20x25x4 filter with one we provide with the gold maintenance plan
Tested aprilaire 600 humidifier
Water panel in good shape, operating normally, no water leaks at this time
Tested NuCalgon iWave ionizer, self test was successful
Blower is in OK condition
Inspected auxiliary heat kit for overheated wiring 
All connections are in good shape
Run tested heating
Witnessed system perform defrost successfully 
After ten minutes of run time, temperature rise was 30⁰, vapor line 141⁰, BTU capacity calculat4d to 42000btu
No concerns found Performed heating maintenance on a 2022 Daikin Fit 17SEER heat pump system
Replaced Honeywell 20x25x4 filter with one we provide with the gold maintenance plan
Tested aprilaire 600 humidifier
Water panel in good shape, operating normally, no water leaks at this time
Tested NuCalgon iWave ionizer, self test was successful
Blower is in OK condition
Inspected auxiliary heat kit for overheated wiring 
All connections are in good shape
Run tested heating
Witnessed system perform defrost successfully 
After ten minutes of run time, temperature rise was 30⁰, vapor line 141⁰, BTU capacity calculat4d to 42000btu
No concerns found

Nate G.

Nate G. Job Checkin

Need 8' ladder Furnace #2 (first furnace inside the attic) Rollout switch tripped Reset, furnace ran for a few minutes then shot flames out the front Furnace has been running OK since All Furnaces are from 1995 Every single system is in various states of disarray and are 30 years old All but one furnace in the attic had tripped rollout switches. Rollout safeties tripped usually indicates bad heat exchangers All 4 attic furnaces are installed improperly: venting and drainage installed incorrectly The two basement systems have been scabbed for parts or are partially disassembled We do not recommend repairs due to age and condition.

Need 8' ladder 
Furnace #2 (first furnace inside the attic)
Rollout switch tripped
Reset, furnace ran for a few minutes then shot flames out the front
Furnace has been running OK since
All Furnaces are from 1995
Every single system is in various states of disarray and are 30 years old
All but one furnace in the attic had tripped rollout switches. 
Rollout safeties tripped usually indicates bad heat exchangers
All 4 attic furnaces are installed improperly: venting and drainage installed incorrectly 
The two basement systems have been scabbed for parts or are partially disassembled 
We do not recommend repairs due to age and condition. Need 8' ladder 
Furnace #2 (first furnace inside the attic)
Rollout switch tripped
Reset, furnace ran for a few minutes then shot flames out the front
Furnace has been running OK since
All Furnaces are from 1995
Every single system is in various states of disarray and are 30 years old
All but one furnace in the attic had tripped rollout switches. 
Rollout safeties tripped usually indicates bad heat exchangers
All 4 attic furnaces are installed improperly: venting and drainage installed incorrectly 
The two basement systems have been scabbed for parts or are partially disassembled 
We do not recommend repairs due to age and condition.

Nate G.

Nate G. Job Checkin

Performed heating maintenance on a 2020 Goodman single stage 96% efficient natural gas furnace Addressed a service bulletin point on the inducer outlet clamp where the manufacturer wants the clamp removed and flipped 90⁰ to prevent potential water leakage No signs of water leaks previously or currently Pulled flame sensor and cleaned Condensate trap is clean and flowing properly 20x25x1 Filter is in good shape, no need to change for a few months Blower wheel in OK condition Exhaust pipe showing no signs of water leaks at fitting glue joints Run tested furnace Gas pressure set to 3.5"wc Temperature rise 62⁰ (spec 35-65) No concerns found on today's visit

Performed heating maintenance on a 2020 Goodman single stage 96% efficient natural gas furnace
Addressed a service bulletin point on the inducer outlet clamp where the manufacturer wants the clamp removed and flipped 90⁰ to prevent potential water leakage
No signs of water leaks previously or currently 
Pulled flame sensor and cleaned
Condensate trap is clean and flowing properly 
20x25x1 Filter is in good shape, no need to change for a few months
Blower wheel in OK condition
Exhaust pipe showing no signs of water leaks at fitting glue joints
Run tested furnace 
Gas pressure set to 3.5"wc
Temperature rise 62⁰ (spec 35-65)
No concerns found on today's visit

Nate G.

Nate G. Job Checkin

Furnace throwing a 31 fault intermittently I went down thinking that was high limit fault and began adjusting temperature rise. Admitted mistake to homeowner and verified the code is for the high pressure switch opening. Cannot verify if intake and exhaust are 100% free of obstructions because the flush mount termination kit is glued onto the exhaust pipe (cover should not be glued to anything, it is held on by 4 screws). Homeowner is going to reach out to the builder to see if they will replace the termination cover. Furnace ran for the entire time I was there without throwing a fault code. It cycled back on and off normally with calls for heat. If the intake and exhaust are clear, next step is a parts warranty pressure switch. Verified inducer is pulling 0.6"wc while heating, switch is rated for .35" Did not see any major variations in the pressure, either. Verified inducer capacitor is measuring the rated 5mfd Looked up a Carrier service bulletin TIC2017-0001 regarding nuisance


Nate G.

Nate G. Job Checkin

Performed heating maintenance on a Trane 2 stage 96% efficient propane-fired furnace Pulled and cleaned flame sensor Checked Condensate lines Adjusted burner Manifold pressure also had to increase house regulator pressure to get burner pressure correct 10"wc high fire 6"wc low fire Temperature rise 35⁰ for both fire rates 16x25x1 filter is in OK condition Signed up for silver maintenance plan


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x4 clean Clean flame sensor Inspect burners - clean no concerns Ohm test igniter: 50.6 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: ok - not in use. Inspect exhaust flu - 2” pvc to 3” pvc no concerns Set thermostat for heat Check amp draw on blower motor: 5.42 Check amp draw on inducer motor:0.38 Check delta T - 48° Furnace is in optimal running conditions


Jason D.

Jason D. Job Checkin

SOLD: 10/20/2025 11:31:40 AM - Option 1 Install New Bryant Single Two Stage Gas Furnace Model #: 927TA60080V21 Serial #: 4025A45376 80,000 BTU’s - 97% AFUE Installation: * Aprilaire 1210 (20X25) Media Air Cleaner * Additional Services - New PVC furnace vents. Level 1 * Reconnect to existing gas line and high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system Warranty: 20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)


SOLD: 10/20/2025 11:31:40 AM - Option 1

Install New Bryant Single Two Stage Gas Furnace
Model #: 927TA60080V21
Serial #: 4025A45376
80,000 BTU’s - 97% AFUE
 
Installation:
* Aprilaire 1210 (20X25) Media Air Cleaner
* Additional Services - New PVC furnace vents. Level 1
* Reconnect to existing gas line and high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system
 
Warranty:
20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
 

SOLD: 10/20/2025 11:31:40 AM - Option 1

Install New Bryant Single Two Stage Gas Furnace
Model #: 927TA60080V21
Serial #: 4025A45376
80,000 BTU’s - 97% AFUE
 
Installation:
* Aprilaire 1210 (20X25) Media Air Cleaner
* Additional Services - New PVC furnace vents. Level 1
* Reconnect to existing gas line and high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system
 
Warranty:
20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

Graham M.

Graham M. Job Checkin

Performed 4 system heating maintenance Replaced 16x25x4 filter for attic heat pump system Bonus room over garage uses a 12.5x20x4 Honeywell filter Cleaned electronic air cleaners for the two basement systems Cleaned flame sensors Cleaned condensate traps Run tested humidifiers Had to clear a blockage on the main floor humidifier water line Water panels are in good shape Bypass dampers are open Main floor furnace needs the 3" exhaust repaired Created estimate and got signature for approval for repair *will reschedule exhaust pipe pvc repairs* Run tested all 4 systems No concerns found for the operation of any system.

Performed 4 system heating maintenance
Replaced 16x25x4 filter for attic heat pump system
Bonus room over garage uses a 12.5x20x4 Honeywell filter
Cleaned electronic air cleaners for the two basement systems 
Cleaned flame sensors
Cleaned condensate traps 
Run tested humidifiers
Had to clear a blockage on the main floor humidifier water line 
Water panels are in good shape
Bypass dampers are open
Main floor furnace needs the 3" exhaust repaired 
Created estimate and got signature for approval for repair 
*will reschedule exhaust pipe pvc repairs*
Run tested all 4 systems
No concerns found for the operation of any system. Performed 4 system heating maintenance
Replaced 16x25x4 filter for attic heat pump system
Bonus room over garage uses a 12.5x20x4 Honeywell filter
Cleaned electronic air cleaners for the two basement systems 
Cleaned flame sensors
Cleaned condensate traps 
Run tested humidifiers
Had to clear a blockage on the main floor humidifier water line 
Water panels are in good shape
Bypass dampers are open
Main floor furnace needs the 3" exhaust repaired 
Created estimate and got signature for approval for repair 
*will reschedule exhaust pipe pvc repairs*
Run tested all 4 systems
No concerns found for the operation of any system.

Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 16x25x4 new today Clean flame sensor Inspect burners - clean no concerns Ohm test igniter: 51.2 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: due soon homeowner requested we return to replace it as soon as available he is aware of our current schedule being far out. Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 7.0 Check amp draw on inducer motor:0.6 Check delta T - 52.1 Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Thermostat reminders needed reset for air filter and humidifier pad. Informed homeowner of stat reminders being 6 month for filter and 12 month for humidifier, turned off reminder for air filter since we change it with maintenance and left humidifier reminder on 12 month. Reset timer and informed Richard of future technicians possibly missing reminder and not resetting it, if that happens it can be reset by a few clicks


Brandon P.

Brandon P. Job Checkin

Upon arrival, system is incoff mode on thermostat. Furnace controlcboard is not showing and current codes. Turned on heating at thermostat to test run operation. Inducer motor kicks on for approximately 3-5 seconds before shutting off and the blower motor kicks on while control board is showing code 6 for reverse polarity or 8mproper ground. Upon deeper inspection, found that the inducer motor is pulling approximately 2.5A on startup, and for the 2-3 seconds of full speed operation, it is operating at 1.7A while being rated for 1.35A. The loud screeching noises previously heard are suspected to be the initial signs of Inducer motor failure. Due to the high Amp draw of the motor, the internal control board relay is failing to keep up and the control board goes into a code 6. Replaced faulty inducer motor with new oem inducer motor. Test run operation in heating mode from control board. System is operating in heating at this time.