725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews

Rated 4.9 out of 5 stars based on 345 customer reviews

Excellent Service by Gregg and his colleague

Greg and his colleague did awesome job balancing and providing recommendations. He also uncovered an issue that was kind a hidden.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

We have used Weston air on several properties and the service is always professional and mechanically well done. The price is fair. What we like is that it’s very realizable,

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding Company!

We have been a customer of Westin Air for four years now and recently had our old HVAC system replaced by Westin Air. They are the most professional HVAC company we’ve ever had with outstanding service and technical excellent. When I had a question about a new sound from our new system when turning on the furnace, Wes the owner personally came to the house to check it out (the sound was normal to the new system). What service! If you have any HVAC needs, call Westin Air.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Chris was great

Showed up in a timely manner and explained everything very well

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Attention to detail

Chris has a great attention to detail and is always willing to help us with our Energy Star Program

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Quality personnel

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service Professional employees!

Very responsive and gets the job done!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Service man showed up on time. Found part to be replaced and explained the problem. Also, gave us an overall status of the unit.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great communication

Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick Response & Excellent Service!

Westin Air continues to exceed my expectations for responsiveness and quality of service! Everyone is extremely friendly, understand and accommodating to help make the situation right! I would highly recommend Westin Air to anyone who wants a reliable, friendly and HONEST HVAC company!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and quick response!

Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Experience!

Chris was Amazing!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

A professional in your own neighborhood

I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs

  • Overall Experience
  • Quality
  • Price
  • Convenience

Takes Pride

Chris takes pride in his works and cares about things getting done properly!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Graham M.

Graham M. Job Checkin

Hookup aid tool and inspect system for faults, found 4 high pressure 999 hot water limit and 4 system resets. Reset faults and informed homeowner of high pressure likely being sourced from dirty filters from previous owners. Inspect refrigerant pressures and loop temps loop pressure low at 5psi pumped up to 40 psi with house water. No concerns at this time humidifier clean and on filter clean.


Nate G.

Nate G. Job Checkin

Performed heating maintenance on a 2015 Trane 2 stage 96% efficient furnace running on propane Replaced filters Checked humidifier... it is not installed properly and as a result has nearly zero airflow through it. Shut it down completely (at humidistat and water valve) Humidifier will waste water and produce negligible humidification performance Furnace blower is clean Wiring in good shape Removed burner box cover Inspected burners Removed flame sensor and clesned Reinstalled flame sensor and burner cover Run tested furnace in high and low fire Ignition is reliable across the burners Gas pressures are correct Temperature rise is within mmanufacturer's specification range Inspected exhaust piping, no signs of leaks Condensate lines show no signs of leaks No water leaks inside the furnace No concerns found on today's visit

Performed heating maintenance on a 2015 Trane 2 stage 96% efficient furnace running on propane
Replaced filters
Checked humidifier... it is not installed properly and as a result has nearly zero airflow through it.  Shut it down completely (at humidistat and water valve)
Humidifier will waste water and produce negligible humidification performance 
Furnace blower is clean
Wiring in good shape
Removed burner box cover
Inspected burners 
Removed flame sensor and clesned 
Reinstalled flame sensor and burner cover
Run tested furnace in high and low fire 
Ignition is reliable across the burners
Gas pressures are correct
Temperature rise is within mmanufacturer's specification range
Inspected exhaust piping, no signs of leaks
Condensate lines show no signs of leaks
No water leaks inside the furnace
No concerns found on today's visit

Nate G.

Nate G. Job Checkin

2013 climatemaster geo system maintenancs Very quickly found the system is low on refrigerant Wants quote to replace with gas furnace, already has natural gas service

2013 climatemaster geo system maintenancs
Very quickly found the system is low on refrigerant 
Wants quote to replace with gas furnace, already has natural gas service 2013 climatemaster geo system maintenancs
Very quickly found the system is low on refrigerant 
Wants quote to replace with gas furnace, already has natural gas service

Brandon P.

Brandon P. Job Checkin

Install new Geo-Link 2-Pump Non-pressurized flow center. Connect to existing lop lines and electric supply. Test run operation and fill to appropriate level. Check again weekly for the first month to top off if any air bubbles are pushed out of the system.


Install new Geo-Link 2-Pump Non-pressurized flow center. Connect to existing lop lines and electric supply. Test run operation and fill to appropriate level. Check again weekly for the first month to top off if any air bubbles are pushed out of the system. 
Install new Geo-Link 2-Pump Non-pressurized flow center. Connect to existing lop lines and electric supply. Test run operation and fill to appropriate level. Check again weekly for the first month to top off if any air bubbles are pushed out of the system.

Jason D.

Jason D. Job Checkin

SOLD: 01/05/2026 12:31:50 PM - Option 2 Install New Bryant HVAC System Bryant Preferred 2-Stage Gas Furnace Model #: 927TA48080V17 Serial #:502558575 80,000 BTU's - 97% AFUE Bryant Single-Stage Air Conditioner Model #: GA5SAN53000W Serial #: 4825X88284 2.5 Ton - 14.3 SEER2 Puron Advance Refrigerant, R-454B Matching Cased Coil: CVAVA3017XMA Serial #: 2525J82728 Installation: * Reconnect to existing gas line and high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system *Air Filtration - AprilAire 1210 (20X25) Media Air Cleaner Warranty: 20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts & Compressor Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)


SOLD: 01/05/2026 12:31:50 PM - Option 2

Install New Bryant HVAC System 
Bryant Preferred 2-Stage Gas Furnace
Model #: 927TA48080V17
Serial #:502558575
80,000 BTU's - 97% AFUE
Bryant Single-Stage Air Conditioner
Model #: GA5SAN53000W
Serial #: 4825X88284
2.5 Ton - 14.3 SEER2
Puron Advance Refrigerant, R-454B
Matching Cased Coil: CVAVA3017XMA
Serial #: 2525J82728
 
Installation:
* Reconnect to existing gas line and high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system
*Air Filtration - AprilAire 1210 (20X25) Media Air Cleaner
 
Warranty:
20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts & Compressor Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

SOLD: 01/05/2026 12:31:50 PM - Option 2

Install New Bryant HVAC System 
Bryant Preferred 2-Stage Gas Furnace
Model #: 927TA48080V17
Serial #:502558575
80,000 BTU's - 97% AFUE
Bryant Single-Stage Air Conditioner
Model #: GA5SAN53000W
Serial #: 4825X88284
2.5 Ton - 14.3 SEER2
Puron Advance Refrigerant, R-454B
Matching Cased Coil: CVAVA3017XMA
Serial #: 2525J82728
 
Installation:
* Reconnect to existing gas line and high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system
*Air Filtration - AprilAire 1210 (20X25) Media Air Cleaner
 
Warranty:
20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts & Compressor Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

Graham M.

Graham M. Job Checkin

Reroute intake to basement and cap off 2” basement supply Need 2” pvc cap. Rotate intake so the air pulls from down low and things can’t be dropped inside pipe. System operational at this time. Intake on side of the house not currently accessible due to thorn bush and uneven ground where intake is located ladder cannot safely reach intake outside.


Graham M.

Graham M. Job Checkin

Upon arrival inspected system and found unit was heating at 27° rise on electric heat. Inspected heat strips and each pulling 16-18 amps and no errors with limits or anything. Air conditioner only outside so unit runs off electric heat only. Unit not satisfying demand Tenant stated unit has always ran constantly for heat and not quite satisfied. Quote replacement unit inside and outside, Pat requested we quote a heat pump and evap coil only for the basement to fit it in the newer air handler case. If coil cannot be sourced to fit in case then quote full air handler heat pump replacement.

Upon arrival inspected system and found unit was heating at 27° rise on electric heat. Inspected heat strips and each pulling 16-18 amps and no errors with limits or anything. Air conditioner only outside so unit runs off electric heat only. Unit not satisfying demand Tenant stated unit has always ran constantly for heat and not quite satisfied. Quote replacement unit inside and outside, Pat requested we quote a heat pump and evap coil only for the basement to fit it in the newer air handler case. If coil cannot be sourced to fit in case then quote full air handler heat pump replacement. Upon arrival inspected system and found unit was heating at 27° rise on electric heat. Inspected heat strips and each pulling 16-18 amps and no errors with limits or anything. Air conditioner only outside so unit runs off electric heat only. Unit not satisfying demand Tenant stated unit has always ran constantly for heat and not quite satisfied. Quote replacement unit inside and outside, Pat requested we quote a heat pump and evap coil only for the basement to fit it in the newer air handler case. If coil cannot be sourced to fit in case then quote full air handler heat pump replacement.

Nate G.

Nate G. Job Checkin

Dip switch setting for freeze protection was incorrect Wiring for humidifier incorrect Verified correct humidifier operation with the thermostat settings Signed up for maintenance plan


Nate G.

Nate G. Job Checkin

Performed heating maintenance on first floor furnace Pulled burgers, they're in good shape Pulled condensate trap and flushed with hot water Pulled flame sensor and cleaned Filter OK Replaced humidifier pad Run tested furnace and performed combustion analysis Combustion numbers are very healthy Low fire 2.2" 38⁰ temp rise Med fire 5.8" 42⁰ temp rise High fire 11" 39⁰ temp rise Furnace is operating within factory specs at this time Heat pump operation is also perfectly within healthy operating numbers at this time: 31,000btu output 150⁰ Vapor line tempature 30⁰ temperature rise 46⁰ outdoor temperature Invoice payable online Also sent maintenance plan as a separate email

Performed heating maintenance on first floor furnace
Pulled burgers,  they're in good shape 
Pulled condensate trap and flushed with hot water 
Pulled flame sensor and cleaned 
Filter OK
Replaced humidifier pad
Run tested furnace and performed combustion analysis
Combustion numbers are very healthy
Low fire 2.2" 38⁰ temp rise 
Med fire 5.8" 42⁰ temp rise
High fire 11" 39⁰ temp rise
Furnace is operating within factory specs at this time

Heat pump operation is also perfectly within healthy operating numbers at this time:
31,000btu output
150⁰ Vapor line tempature
30⁰ temperature rise 
46⁰ outdoor temperature 

Invoice payable online
Also sent maintenance plan as a separate email Performed heating maintenance on first floor furnace
Pulled burgers,  they're in good shape 
Pulled condensate trap and flushed with hot water 
Pulled flame sensor and cleaned 
Filter OK
Replaced humidifier pad
Run tested furnace and performed combustion analysis
Combustion numbers are very healthy
Low fire 2.2" 38⁰ temp rise 
Med fire 5.8" 42⁰ temp rise
High fire 11" 39⁰ temp rise
Furnace is operating within factory specs at this time

Heat pump operation is also perfectly within healthy operating numbers at this time:
31,000btu output
150⁰ Vapor line tempature
30⁰ temperature rise 
46⁰ outdoor temperature 

Invoice payable online
Also sent maintenance plan as a separate email

Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x4 clean Clean flame sensor Inspect burners - clean Ohm test igniter: 59 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.42 Check amp draw on inducer motor:0.49 Check delta T - 53 Furnace is in optimal running conditions


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Tempstar furnace. Replaced 16x25x1 air filter. Clean flame sensor and check ignitor. Visual inspection of burners. Test ran in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. 4" galvanized B-vent in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x4 clean Clean flame sensor Inspect burners - no concerns Ohm test igniter: 64.3 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 4.5 Check amp draw on inducer motor:0.6 Check delta T - 58° Furnace is in optimal running conditions


Nate G.

Nate G. Job Checkin

Performed heating maintenance on a Lennox 93% efficient single stage natural gas furnace Cleared condensate lines of PVC shavings Condensate trap for the furnace is clear Removed burner box cover to gain access to the flame sensor and inspect burners Burners are in good shape Removed flame sensor and cleaned Reinstalled sensor and cover Blower wheel in OK condition Replaced 16x25x1 filter with customer-supplied one No visible signs of water leaks inside or around the furnace Run tested furnace Adjusted gas pressure to 3.5"wc with reference to the sealed burner box No adjustment required to blower speed Temperature rise leveled off at 53⁰, spec is 40-70⁰ Furnace is in good shape, operating within factory specifications at this time No concerns found on today's visit


Graham M.

Graham M. Job Checkin

Upon arrival inspected Ssysyem and found broken inducer cooling wheel. Inform homeowner of noise source and recommend repair with spare wheel from office. Repair was approved obtained wheel and repaired inducer then test ran furnace and performed heating PMI. Gas heating preventative maintenance performed Check filter - clean Clean flame sensor Inspect burners : no concerns Ohm test igniter: 64.3 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 4.21 Check amp draw on inducer motor:0.92 Check delta T - 54° Furnace is in optimal running conditions

Upon arrival inspected Ssysyem and found broken inducer cooling wheel. Inform homeowner of noise source and recommend repair with spare wheel from office. Repair was approved obtained wheel and repaired inducer then test ran furnace and performed heating PMI. 
Gas heating preventative maintenance performed
Check filter - clean
Clean flame sensor
Inspect burners : no concerns 
Ohm test igniter: 64.3
Inspect wiring for loose connections and/or hot spots - none found
Check humidifier pad: n/a
Inspect exhaust flu - no concerns
Set thermostat for heat
Check amp draw on blower motor: 4.21
Check amp draw on inducer motor:0.92
Check delta T -  54°
Furnace is in optimal running conditions Upon arrival inspected Ssysyem and found broken inducer cooling wheel. Inform homeowner of noise source and recommend repair with spare wheel from office. Repair was approved obtained wheel and repaired inducer then test ran furnace and performed heating PMI. 
Gas heating preventative maintenance performed
Check filter - clean
Clean flame sensor
Inspect burners : no concerns 
Ohm test igniter: 64.3
Inspect wiring for loose connections and/or hot spots - none found
Check humidifier pad: n/a
Inspect exhaust flu - no concerns
Set thermostat for heat
Check amp draw on blower motor: 4.21
Check amp draw on inducer motor:0.92
Check delta T -  54°
Furnace is in optimal running conditions

Brandon P.

Brandon P. Job Checkin

Pictures of equipment uploaded to file. Two RTU Systems

Pictures of equipment uploaded to file. Two RTU Systems Pictures of equipment uploaded to file. Two RTU Systems