Greg and his colleague did awesome job balancing and providing recommendations. He also uncovered an issue that was kind a hidden.
Overall Experience
Quality
Price
Convenience
We have used Weston air on several properties and the service is always professional and mechanically well done. The price is fair. What we like is that it’s very realizable,
Overall Experience
Quality
Price
Convenience
We have been a customer of Westin Air for four years now and recently had our old HVAC system replaced by Westin Air. They are the most professional HVAC company we’ve ever had with outstanding service and technical excellent. When I had a question about a new sound from our new system when turning on the furnace, Wes the owner personally came to the house to check it out (the sound was normal to the new system). What service! If you have any HVAC needs, call Westin Air.
Overall Experience
Quality
Price
Convenience
Showed up in a timely manner and explained everything very well
Overall Experience
Quality
Price
Convenience
Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.
Overall Experience
Quality
Price
Convenience
Chris has a great attention to detail and is always willing to help us with our Energy Star Program
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Very responsive and gets the job done!
Overall Experience
Quality
Price
Convenience
Service man showed up on time. Found part to be replaced and explained the problem. Also, gave us an overall status of the unit.
Overall Experience
Quality
Price
Convenience
Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.
Overall Experience
Quality
Price
Convenience
Westin Air continues to exceed my expectations for responsiveness and quality of service! Everyone is extremely friendly, understand and accommodating to help make the situation right! I would highly recommend Westin Air to anyone who wants a reliable, friendly and HONEST HVAC company!!
Overall Experience
Quality
Price
Convenience
Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs
Overall Experience
Quality
Price
Convenience
Chris takes pride in his works and cares about things getting done properly!
Overall Experience
Quality
Price
Convenience
Propane heating preventative maintenance performed Check filter - 20x/5x1 clean Clean flame sensor Inspect burners - no concerns Ohm test igniter: spark no concerns Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 4.22 Check amp draw on inducer motor:0.43 Check delta T - 62° Furnace is in optimal running conditions Heat pump working well keeping up with demand
RTU 2 Upon arrival, the internal breaker was off, and the disconnect for the RTU was off. With both breakers turned on, there is no power being supplied to the unit. Must call an electrician for electrical diagnosis. Once power is supplied to the unit, it is not guaranteed that the unit will operate due to no tests being able to be performed today.
Replace Waterfurnace FP1 sensor Install aftermarket High pressure switch and service tee Also fixed thermostat wire splice that wasn't allowing Y2 to energize at the geo
Gas heating preventative maintenance performed Check filter - 20x25x1 clean Clean flame sensor Inspect burners - no concerns Ohm test igniter: 62 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: #12 due soon advised homeowner to order Inspect exhaust flu - Set thermostat for heat Check amp draw on blower motor: 4.21 Check amp draw on inducer motor:0.82 Check delta T - 54° Furnace is in optimal running conditions
Preventative maintenence inspection on Trane high efficiency furnace running in good condition. 20x25x4 air filter is new as of 1/8. #35 humidifier pad in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Humidifier tested during heating mode test. System is operating properly, efficiently and ready for Winter.
Benchmarked geo heat of extraction to the factory performance chart Unit is dead on for current conditions Noise concerns from ductwork No mechanical noise heard. Sounds like harmonics through the ductwork Tried putting sound dampening on the noisiest return grille
Gas heating preventative maintenance performed Check filter - 20x25x4 new today gold Clean flame sensor Inspect burners - wire brush Ohm test igniter: 54.6 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: #10 sideways - reorient humidifier solenoid stuck open so unit is off. Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 5.23 Check amp draw on inducer motor:0.25 Check delta T - Furnace is in optimal running conditions
Preventative maintenence inspection on Bryant high efficiency furnace running in good condition. 20x25x3 air filter is new today. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.
Remove and replace two pole contactor with the allen lug style, Install additional five amp resettable breaker in place of three amp fuse. run test heat and verify operation Material needed- two pole contactor with lugs and five amp resettable fuse
Upon arrival, system is locked out on E71-Loss of Charge code. Used aid tool to check refrigerant pressures. System is stagnant with 180psi refrigerant system. Performed power reset to clear lockout. Performed operational test in both heating and cooling modes and cross referenced to installers manual to know whether pressure, and temperatures are within spec. Performed heating test first. After 15 minutes of run time, refrigerant pressures and temperatures are within specifications. Ground loop temperature drop is within spec. Air temperature rise is within spec. No issues with the operation of the unit were found. Found that hot water generator lines are swapped based on Waterfurnace installation manual. Disconnect and reconnect hot water generator lines to correct DHW IN and DHW OUT connections.
Dual fuel geo split 5 series 4 ton water furnace Lennox natural gas 2 stage 96% Installing contractor used Lennox evaporator coil as the air coil Geo is low on refrigerant and already has leak sealant in the system Gas furnace was throwing a slew of pressure switch codes Found furnace burner intake pipe full of foliage Cut pipe and cleared blockage. Put intake back together with an unglued coupling for future cleanout Gas furnace operating properly now Removed cover for Lennox coil. No obvious signs of a leak. From experience, the likelihood of the Lennox coil leaking refrigerant is very high. Recommend replacing coil with a water furnace coil 21" wide coil. If taller than 29", reme halo will need removed and humidifier bypass relocated to the side of the plenum.
Gas heating preventative maintenance performed Check filter - 20x25x5 new today gold Clean flame sensor Inspect burners - no concerns Ohm test igniter: 54.6 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: clean Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.92 Check amp draw on inducer motor:1.01 Check delta T - 58° Furnace is in optimal running conditions Gas heating preventative maintenance performed Check filter - 16x25x4 new today gold Clean flame sensor Inspect burners - no concerns Ohm test igniter: 63.2 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: clean Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 2.31 Check amp draw on inducer motor:0.92 Check delta T - 53° Furnace is in optimal running conditions Homeowner stated concerns with 2nd floor unit not seeming to satisfy demand. Did not find any errors with
Preventative maintenence inspection on Trane standard efficiency furnace running in good condition. 16x25x1 air filter is new today. Clean flame sensor and check ignitor. Visual inspection of burners. Test blower capacitor. Run test unit in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. 4" galvanized B-vent in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.
Performed diagnostics on a Daikin Fit heat pump Had multiple faults for a Temperature sensor Sensor is reading good data at this time Unit will not respond to any inputs Starting with replacing the outdoor control board and adding a surge protector to the unit to protect the new board