Greg and his colleague did awesome job balancing and providing recommendations. He also uncovered an issue that was kind a hidden.
Overall Experience
Quality
Price
Convenience
We have used Weston air on several properties and the service is always professional and mechanically well done. The price is fair. What we like is that it’s very realizable,
Overall Experience
Quality
Price
Convenience
We have been a customer of Westin Air for four years now and recently had our old HVAC system replaced by Westin Air. They are the most professional HVAC company we’ve ever had with outstanding service and technical excellent. When I had a question about a new sound from our new system when turning on the furnace, Wes the owner personally came to the house to check it out (the sound was normal to the new system). What service! If you have any HVAC needs, call Westin Air.
Overall Experience
Quality
Price
Convenience
Showed up in a timely manner and explained everything very well
Overall Experience
Quality
Price
Convenience
Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.
Overall Experience
Quality
Price
Convenience
Chris has a great attention to detail and is always willing to help us with our Energy Star Program
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Very responsive and gets the job done!
Overall Experience
Quality
Price
Convenience
Service man showed up on time. Found part to be replaced and explained the problem. Also, gave us an overall status of the unit.
Overall Experience
Quality
Price
Convenience
Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.
Overall Experience
Quality
Price
Convenience
Westin Air continues to exceed my expectations for responsiveness and quality of service! Everyone is extremely friendly, understand and accommodating to help make the situation right! I would highly recommend Westin Air to anyone who wants a reliable, friendly and HONEST HVAC company!!
Overall Experience
Quality
Price
Convenience
Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs
Overall Experience
Quality
Price
Convenience
Chris takes pride in his works and cares about things getting done properly!
Overall Experience
Quality
Price
Convenience
Gas heating preventative maintenance performed low-fire Check filter - 20x25x4 new today Clean flame sensor Inspect burners - clean no concerns Ohm test igniter: 56.4 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: new today #35 truck stock Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 4.20 Check amp draw on inducer motor:0.24 Check delta T - 58° Furnace is in optimal running conditions
Performed heating maintenance on 7 Daikin gas furnaces, one Bryant electric air handler, two Reznor hanging unit heaters, and one Daikin mini split heat pump Replaced all 7 aprilaire 210 filters, replaced HEPA filters and UV bulb for the master bedroom attic system Ordering additional HEPA system maintenance kits and will return to replace all of those In-law suite furnace shows signs of condensation forming in the furnace intake pipe... discussed with Joe about installing a drain fitting to prevent water damage We will install this when we return for the HEPA maintenance Cleaned flame sensors on all furnaces Tested humidifiers and verified no water leaks Verified proper condensate drainage for all 96% efficient furnaces All blower wheels are clean Run tested all heating systems Checked fault code histories Garage heaters: inspected heat exchangers for cracks Cleaned flame sensors Tested operation
Gas heating preventative maintenance performed primary Check filter - 16x25x1 clean Clean flame sensor Inspect burners - no concerns Ohm test igniter: 52.0 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: clean Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 2.64 Check amp draw on inducer motor:0.36 Check delta T - 46° Furnace is in optimal running conditions Primary system Reme-halo 24v air cleaner has gone bad. Still getting 24v but will not operate as intended status light won’t stay on it fades shortly after hooking power up Gas heating preventative maintenance performed secondary Check filter - 20x25x1 clean Clean flame sensor Inspect burners - clean no concerns Ohm test igniter: no concerns Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 1.80 Check amp draw on in
Platinum heating preventative maintenance performed Check filter - 16x25x4 new today Clean flame sensor Inspect burners - clean no concerns Ohm test igniter: 50.8 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a attic system Inspect exhaust flu - 80% no concerns Set thermostat for heat Check amp draw on blower motor: 3.2 Check amp draw on inducer motor:0.9 Check delta T - 56° Furnace is in optimal running conditions
SOLD: 11/18/2025 6:26:26 PM - Option 2 Install New Bryant HVAC System Bryant Preferred 96 Two Stage Gas Furnace Model #: 820TB36045V14A-A Serial #: 4325A17135 45,000 BTU's - 80% AFUE Bryant Single-Stage Air Conditioner Model #: 146SAN01800WAAAB Serial #: 2025E00893 1.5 Ton - 16 SEER2 Puron Advance Refrigerant, R-454B Matching Cased Coil: CVAVA2414XMAEAAA Serial #: 2625J21344 Installation: * Air Filtration - Aprilaire 1410 (16X25) Media Air Cleaner * Reconnect to existing gas line and high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system * Electrical Services - Run New Thermostat Wire * Install Customer Provided Ecobee Thermostat Warranty: 20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts & Compressor Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
Gas heating preventative maintenance performed Check filter - 20x25x1 clean Clean flame sensor Inspect burners - no concerns Ohm test igniter: 57.6 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: #10 clean no need for new today Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 2.31 Check amp draw on inducer motor:0.87 Check delta T - 56° Furnace is in optimal running conditions
Gas heating preventative maintenance performed Check filter - 20x25x4 due soon 12/24 Clean flame sensor Inspect burners - dirty pull and brush Ohm test igniter: 48.6 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: new today truck stock Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.0 Check amp draw on inducer motor:1.8 Check delta T - 57° Furnace is in optimal running conditions Burners cleaned today inspect next year to determine stainless options. Recommend blue monster blue pvc cement for sealing leaking radon pipe. Purchase more #35 panels to keep stock for replacement and purchase more 20x25x4 filters
Pool hall heat pump extremely low on refrigerant Auxiliary heaters are also non-functional Compressor sounds like a bucket of bolts and the oil smells like there is definitely a mechanical issue System also has no provisions for air filters anywhere Need to discuss with Dan the situation before moving forward. Left the power off to prevent further damage
Propane heating preventative maintenance performed Check filter - 20x25x4 ok Clean flame sensor Inspect burners - clean no concerns Ohm test igniter: 56.3 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: ok Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 4.2 Check amp draw on inducer motor:1.2 Check delta T - 56° propane / 31° heat pump Furnace is in optimal running conditions Inspect heat pump and verify unit is clean and running properly. No concerns with heat pump unit heating well
Install New Daikin FIT HVAC System Two Stage - Variable Speed Furnace: Model #: DR80TC0803BN Serial #: 2502235709 80,000 BTU's - 80% AFUE Variable Speed Air Conditioner: Model #: DC6VSS3610 Serial #: Y008405 3 Ton - 17.2 SEER2 *Matching Indoor Coil: Model #: CAPEA3626B3 Serial #: 2511024794 *Daikin One+ Thermostat: DTST-CWBSA-NI-A Serial #: AA2211003169 Installation: * Reconnect to existing gas line and electric * Transition to existing supply and return ductwork * Start up and commission new system * Aprilaire 1210 (20x25) Media Air Cleaner Warranty: 12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed) Daikin manufacturers Lifetime Heat Exchanger Warranty (Annual maintenance must be performed)
Gas heating preventative maintenance performed Check filter - 210 new clean Clean flame sensor Inspect burners - clean no concerns Ohm test igniter: 56.2 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: new today truck stock Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 2.59 Check amp draw on inducer motor:0.41 Check delta T - 55 low 65 high Furnace is in optimal running conditions Replace drain trap gasket for ICP furnace due to leaky trap
Diagnosed weak pressure switch It is rated 0.65"wc, actual pressure across it was 1.1" Tapping on it would get it to close Got a universal pressure switch from truck stock Set it up for 0.65"wc closing pressure, it opens at 0.61"wc Verified numerous times the new pressure switch closes exactly at 0.65", won't close at 0.64" Moved factory port restrictors to the new switch Installed new pressure switch into the furnace Cycled furnace numerous times Furnace is operating normally at this time. Pan under the furnace is holding water, but everything inside and around the furnace is dry Filter shows no signs of water damage Saddle valve for the humidifier was leaking. Shut the water off to it Leak appears to have stopped
Replaced failed transformers in units 13 and 14 Connected smoke detector to unit 12 Had to do additional troubleshooting for unit 14: Thermostat wire needs repaired between thermostat and the unit. Jim said other company was responsible for that Found heat exchanger also has two holes Created proposal for heat exchanger replacement $6100 with roughly a 2 week lead time to receive the parts.
Gas heating preventative maintenance performed Check filter - 20x25x4 Clean flame sensor set gas to 3.2 from 3.6 Set ac speeds for 1275cfm 3.5 ton Inspect burners - no concerns Ohm test igniter: 56.7 Inspect wiring for loose connections and/or hot spots - no concerns Check humidifier pad: new today Inspect exhaust flu - no concerns all connections tight Set thermostat for heat Check amp draw on blower motor: 4.92 Check amp draw on inducer motor:0.83 Check delta T - 63° Furnace is in optimal running conditions
Performed heating maintenance on a 2025 Bryant Evolution 97% efficient modulating natural gas furnace Replaced aprilaire 210 filter with the one provided with platinum maintenance Disassembled aprilaire 600 humidifier #35 water panel in good shape Reassembled, opened humidifier bypass damper to winter position Verified correcr operation and no water leaks at this time Pulled flame sensor and cleaned Condensate trap clear No signs of gasket leaks internal to the furnace cabinet Burners are spotless No signs of any corrosion to heat exchanger front cell panel and inlet to primary cells Run tested furnace Low fire for 15 minutes: Gas pressure set to 0.5"wc Temperature rise 39⁰ (spec 35-65⁰) High fire for 15 minutes: Gas pressure set to 3.2"wc Temperature rise 50⁰ (spec 40-70⁰) Everything is in perfect shape and operating within factory specs at this time