Greg and his colleague did awesome job balancing and providing recommendations. He also uncovered an issue that was kind a hidden.
We have used Weston air on several properties and the service is always professional and mechanically well done. The price is fair. What we like is that it’s very realizable,
We have been a customer of Westin Air for four years now and recently had our old HVAC system replaced by Westin Air. They are the most professional HVAC company we’ve ever had with outstanding service and technical excellent. When I had a question about a new sound from our new system when turning on the furnace, Wes the owner personally came to the house to check it out (the sound was normal to the new system). What service! If you have any HVAC needs, call Westin Air.
Showed up in a timely manner and explained everything very well
Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.
Chris has a great attention to detail and is always willing to help us with our Energy Star Program
Very responsive and gets the job done!
Service man showed up on time. Found part to be replaced and explained the problem. Also, gave us an overall status of the unit.
Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.
Westin Air continues to exceed my expectations for responsiveness and quality of service! Everyone is extremely friendly, understand and accommodating to help make the situation right! I would highly recommend Westin Air to anyone who wants a reliable, friendly and HONEST HVAC company!!
Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.
I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs
Chris takes pride in his works and cares about things getting done properly!
Upon arrival the system was running in cooling mode and set to 73 and shortly after arrival shut off due to a satisfied thermostat. Initial inspection of all the equipment discovers that all equipment in the basement is running in very good condition including a replacement 3\4hp blower by a third party. And with a clean 16x25X1 pleated air filter Blower dip switches are set to 4 ton with a matching 3 ton ac 15 seer ac system validating maximum blower speed for maximum air volume on the second floor. No additional blower volume or speed is available for this system. As is the equipment is producing 52° supply temperature in the basement. Outdoor equipment inspection discovers a heavily matted condenser coil but still nearly perfect running refrigerant pressures under today's conditions. Replacement turbo 200 capacitor is good Water flush condenser coil and return all equipment to normal service and settings. *** To even out temperatures throughout the house especially from Floor t
remove and replace bad ECM blower with factory replacement test run system verify cooling and refrigerant pressures are adequate
Install new Bryant air conditioner and evap coil Equipment: Air Conditioner-GA5SAN54200W 14.3 SEER2 Single-Stage Air Conditioner with Puron Advance Refrigerant, R-454B, 3.5 Ton Coil- Matching evap coil Installation: *Reuse existing thermostat *Reconnect to existing high voltage electric *Transition to existing supply and return ductwork *Install A2L integration board *Start up and commission new system Warranty: 10 Year Bryant manufacturers parts warranty (Annual maintenance must be performed) 2 Year Westin Air labor warranty (Annual maintenance must be performed)
Homeowners complaints of rhythmic vibration/harmonic noise coming from the outdoor unit and audible inside the house was heard upon arrival. During basement inspection the thermostat temperature was set lower and second stage engaged. Replaced air filter installed in April provided by homeowner Rent test cooling mode at 52° supply temperature Confirm humidifier damper closed Confirm multi-stage cooling operation Outdoor equipment was slightly low on refrigerant charge measuring 3.5 subcooling specked at 8.0. Turbo 200 capacitor is within specs Amp and vote readings within specs at 14.1\238 Balanced refrigerant charge with 7 oz R410A to increase sub cooling to 7.9 All equipment is running in very good condition considering 7 years old. Homeowner is interested in compressor warranty to resolve the issues Seth will consult with Justin and Trane and follow up with homeowners ASAP Homeowner will finalize the invoic thing via online payment link
Upon arrival discovered system not coming on inside. Outdoor unit cycling but no blower function at air handler. Quote replacement motor for system. Advise to shut down humidifier permanently to prevent future leaks and if humidity is needed than the humidifier should be reconfigured due to leaking. Remove and replace blower motor and test run cooling system cooling after repairs with 6° subcool. Advised of the leaning condenser and no screws securing unit to the brackets. Photos for reference.
Performed cooling maintenance on a Trane XL18 Two stage AC system Cleared alerts from the thermostat Cleaned electronic air cleaner pre-filter and collection cells Put Condensate treatment in the evaporator coil drain pan to mitigate drain clogging issues like we experienced last winter Water is flowing properly from the Condensate drain to the floor drain Blower is clean Washed outdoor unit with water Refrigerant charge is in spec Capacitor and Amp draws in spec Found refrigerant lines touching each out inside the unit behind the removable grille Adjusted tubing positioning to eliminate rubbing This prevented an immenent loss of refrigerant at that contact point and also quieted down the vibration noise from the unit. System is clean and operating within factory specifications at this time.
Water furnace 5 series water to air package no electric auxiliary Water furnace NSW 018 water to water hydronic heater April there 600 Carrier high efficiency gas furnace Upon arrival homeowners immediate concerns were the water to water geothermal had no lights on the display. After initial inspection and attempted diagnostics with a power reset the display illuminated and the system is running normal. System was in standby mode and homeowner wanted to turn on for the season. Water furnace tech services recommends monitoring the system and replacing the control board if similar symptoms occur Rheem communicating high efficiency gas furnace manufactured 2016 is running in fair to good condition. This system gets very little use but fired up and ran in multi-stage gas heating mode on the first attempt Diagnostics on the aprilaire 600 concluded that the automatic controls were disabled and removed from the old geothermal and never installed anywhere else. This humidifier has never
Install Aprilaire E100 Dehumidifier. Dehumidifier set in front of furnace and waterheater. Outlet side of dehumidifier piped into return duct on furnace. Drain line ran on its own to floor drain. Controlled from built in controller on dehumidifier. 120v electric hooked up to power cord for current stand alone dehumidifier. Test ran operation and set to 55%. Serial# 312025A74506 5 Year Parts Warranty 1 Year Labor Warranty Due to ongoing renovations, it is recommended to have a full duct cleaning after renovations are complete. Westin Air recommends Fresh Air Corps, and tell them Brandon sent you! Thank You!
Remove and replace 45+5 run capacitor and test run system. Running at 11° subcool 15° superheat. Wash coil. Quoted new 600m humidifier including new pipe and drain. Replaced air filter with on site 20x25x4
SOLD: 08/28/2025 2:49:33 PM - Option 2 Install new Bryant HVAC system Equipment: Furnace- 987MC42080C17 Bryant, Evolution, 97% AFUE, Modulating, 4-Way Multipoise, VCA ECM, Gas Furnace, 80,000 BTU, 1400 CFM, 17.5" width Serial# 2525A59719 AC- 191VAN03600W 21 SEER2 Evolution Extreme Variable Speed Air Conditioner with Puron Advance Refrigerant, R-454B, 3 Ton, 208/230 Volt, 1 Phase, SW AC Serial# 2825E05390 Coil- CVAVA3617XMAEAAA Serial# 1325J57110 *Bryant Evolution Thermostat SYSTXBBECC01-B Serial# 4324W22318 *Air Filtration - AprilAire 1210 (20X25) Media Air Cleaner *Humidifier - AprilAire 600M *Dehumidifier - AprilAire E100 Installation: *Reconnect to existing gas line and high voltage electric *Transition to existing supply and return ductwork *Start up and commission the new system *Ductwork - Add Return Air * Remove insulation and properly support main supply duct Warranty: 10 Year Bryant manufacturers parts warranty (Annual maintenance must be performed) 5 Year Westin Air labo
Two system water furnace geothermal heating season maintenance tune-up cleaning inspection safety inspection and heating fire off Primary house basement system carrier gas furnace dual fuel with water furnace 5 series split Geothermal system is running in very good condition with full non-pressurized reservoir and no active or historical service codes on the computer Aurora AXB computer scan Gas heating maintenance tune up on the carrier is also in very good condition, aprilaire 210 filter is acceptable and was returned to service with no replacement required. Partial disassembly of condensation drain pump for sludge clean out. Remove and resurface flame sensor. Run test equipment in multi-stage gas heating mode April there 600A humidifier The humidifier has a very finicky solenoid water valve that opens every time but closes very slowly and intermittently continues to dribble. After disassembly three different times to ensure proper sealing during shut off the system is workin
Two system geothermal split equipment heating season preventive maintenance, tune-up, cleaning, safety inspection, and minor repairs All carrier equipment is original to the house in 2006. The zoned first floor system consists of a 120K BTU propane gas furnace combined with a carrier 4 ton r22 split geothermal single stage. The second floor system consists of a 15KW electric air handler in the second floor unfinished area supplying only the second floor. This system is combined with a 3.5 ton carrier single stage r22 system geothermal Both systems are running in fair to good condition considering the age. Both geothermals are functioning in heating and cooling modes. The geothermal non-pressurized flow centers both tests between 0.982 and 0.985 equivalent to roughly +18-+20°f freeze protection for the winter. Both non-pressurized QT flow centers required about 2 gallons top off of fresh house water The aprilaire 600 humidifier required a solenoid valve replacement to stop the con
Gas heating preventative maintenance performed Check filter - 16x25x1 new today Clean flame sensor Ohm test igniter: spark n/a no concerns Inspect wiring for loose connections and/or hot spots - none found Inspect exhaust flu - no concerns 4” round Set thermostat for heat Check amp draw on inducer motor: 1.0 Check delta T - 50° running hot building at 78° upon arrival Furnace is in optimal running conditions
Replacement warranty Inspector did not get the furnace blower door on properly and the door switch was not depressed fully Put a zip tie in the door switch to prevent nuisance issues System operating properly at this time.
Upon arrival inspected unit and found bad 45+5 run capacitor. Replace with van stock 45+5 and test run system. Unit came back on cooling no issues. Homeowner stated filter was replaced today. Outdoor coil completely clogged and needs washed. Washed outdoor unit to prevent future breakdowns and allow unit to breathe properly. System is cooling at 11° superheat