725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews

Rated 4.9 out of 5 stars based on 345 customer reviews

Excellent Service by Gregg and his colleague

Greg and his colleague did awesome job balancing and providing recommendations. He also uncovered an issue that was kind a hidden.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

We have used Weston air on several properties and the service is always professional and mechanically well done. The price is fair. What we like is that it’s very realizable,

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding Company!

We have been a customer of Westin Air for four years now and recently had our old HVAC system replaced by Westin Air. They are the most professional HVAC company we’ve ever had with outstanding service and technical excellent. When I had a question about a new sound from our new system when turning on the furnace, Wes the owner personally came to the house to check it out (the sound was normal to the new system). What service! If you have any HVAC needs, call Westin Air.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Chris was great

Showed up in a timely manner and explained everything very well

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Attention to detail

Chris has a great attention to detail and is always willing to help us with our Energy Star Program

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Quality personnel

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service Professional employees!

Very responsive and gets the job done!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Service man showed up on time. Found part to be replaced and explained the problem. Also, gave us an overall status of the unit.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great communication

Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick Response & Excellent Service!

Westin Air continues to exceed my expectations for responsiveness and quality of service! Everyone is extremely friendly, understand and accommodating to help make the situation right! I would highly recommend Westin Air to anyone who wants a reliable, friendly and HONEST HVAC company!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and quick response!

Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Experience!

Chris was Amazing!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

A professional in your own neighborhood

I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs

  • Overall Experience
  • Quality
  • Price
  • Convenience

Takes Pride

Chris takes pride in his works and cares about things getting done properly!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Brandon P.

Brandon P. Job Checkin

Perform Cooling preventative maintenence inspection on five Bryant rooftop package units. Four of the five units are operating properly within specifications. Tested refrigerant levels, outdoor fan capacitors, and blower fan capacitors. Water flushed condenser coils, evaporator coil condensation drain pans, and condensation drain traps. Test ran operational units from respective thermostats. Thermostats do not require batteries. Replaced two 16x25x2 in each unit.


seth p.

seth p. Job Checkin

To system gas furnace air conditioning cooling season preventive maintenance inspection, tune up, cleaning, safety inspection Replace both air filters included with gold plan. Basement system - RP2200 Honeywell pop up space guard replacement, adding system Honeywell 20x25x4 pleated disposable media, basement system plenum and drain are sealed and not serviceable. Shut down both humidifiers downstairs and perform minor maintenance cleaning on both systems. Inspect and clean attic system evap drain pan and drain line Test run both outdoor condensers in cooling mode. Second floor replacement system is running in excellent condition with all electronics and refrigerant pressures within specs. Basement system is 25 years old this season with a 2000 serial number and r22 refrigerant. Ac equipment is running in fair to good condition although under today's conditions the refrigerant pressures are registering lower than normal but most likely due to no heat load indoors with 64 return air a


Jeramie T.

Jeramie T. Job Checkin

Install New Daikin FIT Dual Fuel HVAC System *Modulating - Variable Speed Furnace: Model #: DM97MC0804CNAB Serial #: 2411299346 80,000 BTU's - 97% AFUE *Variable Speed Heat Pump: Model #: DZ6VSA421EAB Serial #: 2309060937 3.5 Ton - 17 SEER2, 8.5 HSPF2 *Matching Indoor Coil: Model #: CAPEA6030D4AA Serial #: 2408202848 *Daikin One+ Thermostat: DTST-CWBSA-NI-A Serial #: AA2207002283 Installation: * Reconnect to existing gas line and electric * Transition to existing supply and return ductwork * Start up and commission new system * Aprilaire 1210 (20x25) Media Air Cleaner * Aprilaire 700m Fan Powered Humidifier * Replace Return Air Drop * New PVC Furnace Vents * Replace 2 Supply Runs with Hard Pipe Warranty: 12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed) Daikin manufacturers Lifetime Heat Exchanger Warranty (Annual maintenance must be performed)

Install New Daikin FIT Dual Fuel HVAC System
*Modulating - Variable Speed Furnace:
Model #: DM97MC0804CNAB
Serial #: 2411299346
80,000 BTU's - 97% AFUE
*Variable Speed Heat Pump:
Model #: DZ6VSA421EAB
Serial #: 2309060937
3.5 Ton - 17 SEER2, 8.5 HSPF2
*Matching Indoor Coil: 
Model #: CAPEA6030D4AA
Serial #: 2408202848
*Daikin One+ Thermostat: DTST-CWBSA-NI-A
Serial #: AA2207002283

Installation:
* Reconnect to existing gas line and electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* Aprilaire 1210 (20x25) Media Air Cleaner
* Aprilaire 700m Fan Powered Humidifier
* Replace Return Air Drop
* New PVC Furnace Vents
* Replace 2 Supply Runs with Hard Pipe

Warranty:
12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
Daikin manufacturers Lifetime Heat Exchanger Warranty (Annual maintenance must be performed)

Nate G.

Nate G. Job Checkin

Performed spring hvac maintenance Bosch dual fuel system Natural gas two stage furnace Variable speed heat pump Zone panel with 4 zones Humidifier Closed humidifier bypass damper, will need opened in fall Verified correct operation of the system Furnace blower was caked full of drywall dust from construction (Blower cleaning is a $300 service, included with platinum plan if needed, no cost today) Pulled blower out of the furnace Removed the motor Took the housing and wheel outside Washed with water and brush Blower is now clean like new Brush cleaned and vacuumed secondary heat exchanger on the furnace Reassembled blower housing and motor Reinstalled blower in the furnace Tested operation Filter is still good. Left a new 20x25x4 Honeywell filter since provided filters are included with each maintenance visit. Outdoor unit is clean and operating within factory specifications

Performed spring hvac maintenance 
Bosch dual fuel system
Natural gas two stage furnace
Variable speed heat pump
Zone panel with 4 zones 
Humidifier

Closed humidifier bypass damper, will need opened in fall
Verified correct operation of the system
Furnace blower was caked full of drywall dust from construction 
(Blower cleaning is a $300 service, included with platinum plan if needed, no cost today)
Pulled blower out of the furnace
Removed the motor
Took the housing and wheel outside
Washed with water and brush
Blower is now clean like new
Brush cleaned and vacuumed secondary heat exchanger on the furnace
Reassembled blower housing and motor 
Reinstalled blower in the furnace
Tested operation 

Filter is still good.  Left a new 20x25x4 Honeywell filter since provided filters are included with each maintenance visit.

Outdoor unit is clean and operating within factory specifications

Nate G.

Nate G. Job Checkin

Performed cooling maintenance on Water Furnace Series 5 geothermal heat pump Inspected wiring: all connections tight and secure. No signs of overheated wiring, including the auxiliary heat strip wiring Capacitor measured 39mfd, rating is 40 Used a no-rinse foaming evaporator coil cleaner on the air coil. Condensation produced during cooling mode will wash away any soil buildup. Coil was not dirty except on the edges Put Condensate drain treatment tablets in the Condensate pan Replaced filter Run tested system with Aurora Aid Tool Refrigerant numbers are nominal Water source closed loop numbers also are nominal System performance is on par with factory specifications at this timqe


seth p.

seth p. Job Checkin

Three system Waterfurnace geothermal 5 series package systems 2 alcohol ground loops pressurized with three flow centers, repressurized both to 65 PSI Inspected and reinstalled all existing air filters dated in January Clean and flush all drain systems and minor maintenance cleaning of all systems System B had 25 FP1 service codes But is running in excellent condition today. Suspect lower than desirable ground loop antifreeze pressure All equipment is running in very good condition and ready for summer


Nate G.

Nate G. Job Checkin

Performed cooling maintenance Blower is clean Indoor coil clean Adjusted positioning of TXV tubing to prevent rubbing from mechanical vibration Changed filter Closed humidifier bypass damper Outdoor coil is clean Capacitor 36.5/7.5 rated 40/7.5 +/-10% Replaced spade terminal for the start wire on the Compressor to the capacitor terminal Installed turbo 200 capacitor


Graham M.

Graham M. Job Checkin

Upon arrival inspected thermostat and found it in “waiting for update” could not connect to the WiFi and after I removed the saved WiFi memory it wouldn’t let me reconnect at all continued to throw error. Test replaced the thermostat to verify not an internal issue and still won’t connect. Homeowner couldn’t connect her laptop from that room either. Believed issue was in the router for that portion of the house recommended she reset that router or have the company come out so she called them.


seth p.

seth p. Job Checkin

2014 Trane EnviroWise geothermal split system with TAM5 air handler Air filter replaced by homeowners on schedule, inspect indoor air coil and flush drain system, inspect all electronics and perform minor maintenance cleaning. Test run Honeywell vision pro 8000 thermostat in multi-stage cooling geothermal heat pump mode Test run outdoor unit and cooling mode, repressurize alcohol ground loops from 20 to 45 PSI for summer time Clean and inspector outdoor electronics compartment and flow center motor Relevel outdoor unit permapad and wash down outdoor system


Jason D.

Jason D. Job Checkin

Install New Daikin FIT HVAC System *Two Stage - Variable Speed Furnace: Model #: DM80VC0604BNAD Serial #: 2406155414 60,000 BTU's - 80% AFUE *Variable Speed Air Conditioner: Model #: DX6VSS3010AB Serial #: 2406161849 2.5 Ton - SEER2 *Matching Indoor Coil: Model #: CAPEA3026B4BA Serial #: 2408174775 *Daikin One+ Thermostat: DTST-TOU-A Serial #: EA2405006300 Installation: * Reconnect to existing gas line and electric * Transition to existing supply and return ductwork * Start up and commission new system * Aprilaire 1210 (20x25) Media Air Cleaner * Remove old humidifier and patch drop Warranty: 12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed) Daikin manufacturers Lifetime Heat Exchanger Warranty (Annual maintenance must be performed)

Install New Daikin FIT HVAC System
*Two Stage - Variable Speed Furnace:
Model #: DM80VC0604BNAD
Serial #: 2406155414
60,000 BTU's - 80% AFUE
*Variable Speed Air Conditioner:
Model #: DX6VSS3010AB
Serial #: 2406161849
2.5 Ton -  SEER2
*Matching Indoor Coil:
Model #: CAPEA3026B4BA
Serial #: 2408174775
*Daikin One+ Thermostat: DTST-TOU-A
Serial #: EA2405006300

Installation:
* Reconnect to existing gas line and electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* Aprilaire 1210 (20x25) Media Air Cleaner
* Remove old humidifier and patch drop

Warranty:
12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
Daikin manufacturers Lifetime Heat Exchanger Warranty (Annual maintenance must be performed)

seth p.

seth p. Job Checkin

1997 water furnace Spectra r22 geothermal 4 ton system is locked out on low pressure switch due to a complete loss of all refrigerant. The high pressure discharge line has split open at the service port connection and is non-reparable The geothermal package equipment is currently set to emergency heat mode on the thermostat and no other repairs can be performed on the system. *All equipment needs replaced* The pressurized ground loop continued to hold 40 PSI after recharging to 65psi exactly one year ago on April 15th 2024 The antifreeze solution is confirmed alcohol measuring 0.978 The ground loop pressure is now at zero after extracting enough solution for the test The homeowners are currently out of the country until the first week of May in the house is being cared for by the parents Please contact Dana for any correspondences until David returns Cathy shankland will be in contact ASAP

1997 water furnace Spectra r22 geothermal 4 ton system is locked out on low pressure switch due to a complete loss of all refrigerant. The high pressure discharge line has split open at the service port connection and is non-reparable

The geothermal package equipment is currently set to emergency heat mode on the thermostat and no other repairs can be performed on the system. 
*All equipment needs replaced*

The pressurized ground loop continued to hold 40 PSI after recharging to 65psi exactly one year ago on April 15th 2024
The antifreeze solution is confirmed alcohol measuring 0.978 
The ground loop pressure is now at zero after extracting enough solution for the test

The homeowners are currently out of the country until the first week of May in the house is being cared for by the parents 
Please contact Dana for any correspondences until David returns

Cathy shankland will be in contact ASAP

Brandon P.

Brandon P. Job Checkin

See notes

See notes

Nate G.

Nate G. Job Checkin

Construction warranty. Humidifier was not wired to the furnace. Wired everything up Setup humidifier on the thermostats Adjusted humidity settings Verified correct operation No water leaks Gave a tutorial of the system Explained operation and expected behavior of the equipment Leveled aprilaire dehumidifier Adjusted dehumidifier set point to 55% It was set to 45% and never shut off, he said


Brandon P.

Brandon P. Job Checkin

2007 Rheem R-22 AC running in good condition despite age. 20x25x4 air filter is new on 4-1. Unable to inspect indoor coil due to door not being removable without cutting drain line and exhaust vent. Flushed coil drain pan through safety switch. Test ran in cooling mode from thermostat. Delta t of 18F with supply temp of 50F. R-22 refrigerant pressures are within spec for low outdoor temperature. High 110psi with 14F SC, low 50psi with 13F SH. Outdoor coils are in clean condition. Recommend checking again when Bradford Pear trees have dropped their flowers. Dual run capacitor, compressor, and fan motor are all operating within spec. No issues found on today's visit. System is operational and ready for Summer.

2007 Rheem R-22 AC running in good condition despite age. 20x25x4 air filter is new on 4-1. Unable to inspect indoor coil due to door not being removable without cutting drain line and exhaust vent. Flushed coil drain pan through safety switch. Test ran in cooling mode from thermostat. Delta t of 18F with supply temp of 50F. R-22 refrigerant pressures are within spec for low outdoor temperature. High 110psi with 14F SC, low 50psi with 13F SH. Outdoor coils are in clean condition. Recommend checking again when Bradford Pear trees have dropped their flowers. Dual run capacitor, compressor, and fan motor are all operating within spec. No issues found on today's visit. System is operational and ready for Summer.

Jeramie T.

Jeramie T. Job Checkin

See Notes

See Notes