Rated 4.9 out of 5 stars based on 345 customer reviews

Excellent Service by Gregg and his colleague

Greg and his colleague did awesome job balancing and providing recommendations. He also uncovered an issue that was kind a hidden.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

We have used Weston air on several properties and the service is always professional and mechanically well done. The price is fair. What we like is that it’s very realizable,

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding Company!

We have been a customer of Westin Air for four years now and recently had our old HVAC system replaced by Westin Air. They are the most professional HVAC company we’ve ever had with outstanding service and technical excellent. When I had a question about a new sound from our new system when turning on the furnace, Wes the owner personally came to the house to check it out (the sound was normal to the new system). What service! If you have any HVAC needs, call Westin Air.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Chris was great

Showed up in a timely manner and explained everything very well

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Attention to detail

Chris has a great attention to detail and is always willing to help us with our Energy Star Program

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Quality personnel

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service Professional employees!

Very responsive and gets the job done!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Service man showed up on time. Found part to be replaced and explained the problem. Also, gave us an overall status of the unit.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great communication

Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick Response & Excellent Service!

Westin Air continues to exceed my expectations for responsiveness and quality of service! Everyone is extremely friendly, understand and accommodating to help make the situation right! I would highly recommend Westin Air to anyone who wants a reliable, friendly and HONEST HVAC company!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and quick response!

Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Experience!

Chris was Amazing!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

A professional in your own neighborhood

I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs

  • Overall Experience
  • Quality
  • Price
  • Convenience

Takes Pride

Chris takes pride in his works and cares about things getting done properly!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Trane standard efficiency XV80 furnace. 20x25x4 air filter in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Test run operation in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. 4" galvanized B-vent in good condition. 0PPM CO detected during testing. No issues found during inspection. System is operating properly, efficiently and ready for Winter.


Nate G.

Nate G. Job Checkin

Performed heating maintenance on two basement furnaces 2023 Payne single stage 95% efficient 120kbtu Replaced 20x25x4 filter Cleaned flame sensor Found condensate trap gasket leaking inside the furnace Replaced trap gasket and flushed trap with water Furnace cycling on high limit due to insufficient return duct tied into the furnace Compensated with reducing gas pressure down to 3.0"wc and increasing blower speed to max Furnace is no longer overheating 2011 Lennox single stage 93% furnace Cleared condensate lines inside the furnace Trap is clear Replaced 20x25x4 filter Cleaned flame sensor This furnace is operating within specs without any adjustments today

Performed heating maintenance on two basement furnaces
2023 Payne single stage 95% efficient 120kbtu
Replaced 20x25x4 filter
Cleaned flame sensor
Found condensate trap gasket leaking inside the furnace 
Replaced trap gasket and flushed trap with water
Furnace cycling on high limit due to insufficient return duct tied into the furnace 
Compensated with reducing gas pressure down to 3.0"wc and increasing blower speed to max
Furnace is no longer overheating


2011 Lennox single stage 93% furnace
Cleared condensate lines inside the furnace
Trap is clear
Replaced 20x25x4 filter
Cleaned flame sensor
This furnace is operating within specs without any adjustments today Performed heating maintenance on two basement furnaces
2023 Payne single stage 95% efficient 120kbtu
Replaced 20x25x4 filter
Cleaned flame sensor
Found condensate trap gasket leaking inside the furnace 
Replaced trap gasket and flushed trap with water
Furnace cycling on high limit due to insufficient return duct tied into the furnace 
Compensated with reducing gas pressure down to 3.0"wc and increasing blower speed to max
Furnace is no longer overheating


2011 Lennox single stage 93% furnace
Cleared condensate lines inside the furnace
Trap is clear
Replaced 20x25x4 filter
Cleaned flame sensor
This furnace is operating within specs without any adjustments today

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Carrier high efficiency furnace running in good condition. 20x25x1 air filter is new today. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.


Jason D.

Jason D. Job Checkin

Install New Bryant Two Stage Gas Furnace Model #: 927TA48060V17A-A Serial #: 4625A43526 60,000 BTU’s - 97% AFUE Installation: *Reconnect to existing gas line and high voltage electric *Transition to existing supply and return ductwork *Reuse existing filter rack *Reuse existing thermostat *Start up and commission the new equipment Warranty: 10 Year Bryant manufacturers parts warranty (Annual maintenance must be performed) 1 Year Westin Air labor warranty (Annual maintenance must be performed)


Nate G.

Nate G. Job Checkin

Performed heating maintenance on a Trane S9X2 two stage 96% efficient natural gas furnace Replaced 16x25x4 filter Blew out Condensate trap No signs of water leaks inside the furnace, external drain lines, or vent piping Pulled flame sensor and cleaned Burners in good shape Run tested furnace Motor Amp draws within spec No odd noises from either motor High fire gas pressure 3.5"wc Temperature rise 49⁰ Low fire gas pressure 1.7"wc Temperature rise 42⁰ Temperature rise specification is 35-65⁰ No concerns found on today's visit Furnace is operating within factory specifications at this time

Performed heating maintenance on a Trane S9X2 two stage 96% efficient natural gas furnace 
Replaced 16x25x4 filter
Blew out Condensate trap
No signs of water leaks inside the furnace, external drain lines, or vent piping
Pulled flame sensor and cleaned
Burners in good shape 
Run tested furnace
Motor Amp draws within spec
No odd noises from either motor
High fire gas pressure 3.5"wc
Temperature rise 49⁰
Low fire gas pressure 1.7"wc
Temperature rise 42⁰
Temperature rise specification is 35-65⁰
No concerns found on today's visit
Furnace is operating within factory specifications at this time

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on 2016 Lennox standard efficiency furnace. 16x25x1 air filter in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Test blower capacitor. Test ran operation from thermostat call for heat. Temperature rise is within specs. Blower and inducer motors tested good. 4" galvanized B-vent in good condition and no sign of leaks. 0PPM CO detected during testing. Tested operation of humidifier during heating test. Solenoid opens properly but no water comes out. After further investigation, found that the saddle valve on the water line is not letting any water out. Attempted to unplug by closing and reopening multiple times with no luck. Saddle piercing valve will need replaced for proper humidifier operation. Aside from above mentioned issue, the furnace tested within specifications and is safe to operate.

Preventative maintenence inspection on 2016 Lennox standard efficiency furnace. 16x25x1 air filter in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Test blower capacitor. Test ran operation from thermostat call for heat. Temperature rise is within specs. Blower and inducer motors tested good. 4" galvanized B-vent in good condition and no sign of leaks. 0PPM CO detected during testing. Tested operation of humidifier during heating test. Solenoid opens properly but no water comes out. After further investigation, found that the saddle valve on the water line is not letting any water out. Attempted to unplug by closing and reopening multiple times with no luck. Saddle piercing valve will need replaced for proper humidifier operation. Aside from above mentioned issue, the furnace tested within specifications and is safe to operate.

Nate G.

Nate G. Job Checkin

Replace failed defrost board Heat pump functioning normally at this time.


Graham M.

Graham M. Job Checkin

Upon arrival, inspected systems and did not find any concerns with HVAC systems. Checked ohms for wiring supplying disconnects and found a few wires with direct shorts to ground reading 0.0 and a few wires with .60 ohms on them. OL on all wires supply HVAC units. No issues discovered with hvac equipment errors are internal in the electrical supply


Nate G.

Nate G. Job Checkin

Closed


Nate G.

Nate G. Job Checkin

Daikin ductless split heat pump current fault code for out of refrigerant Lykens property management came to provide roof access Figured out which unit on the roof belongs to this system System is 100% out of refrigerant Customer has records from property management work orders regarding system not operating normally back to when they took possession of the space Maintenance filled the refrigerant without locating the leak and called it good Installation of the system is extremely poor quality Traced refrigerant line set through the restaurant next door's basement Unsure how the lines are ran to get to the indoor head between the restaurant wall and theirs Recommend replacing the system and the line set All of these issues are pre-existing to the customer taking possession of the space from the rental company

Daikin ductless split heat pump current fault code for out of refrigerant 
Lykens property management came to provide roof access
Figured out which unit on the roof belongs to this system
System is 100% out of refrigerant
Customer has records from property management work orders regarding system not operating normally back to when they took possession of the space
Maintenance filled the refrigerant without locating the leak and called it good
Installation of the system is extremely poor quality
Traced refrigerant line set through the restaurant next door's basement
Unsure how the lines are ran to get to the indoor head between the restaurant wall and theirs

Recommend replacing the system and the line set
All of these issues are pre-existing to the customer taking possession of the space from the rental company
Daikin ductless split heat pump current fault code for out of refrigerant 
Lykens property management came to provide roof access
Figured out which unit on the roof belongs to this system
System is 100% out of refrigerant
Customer has records from property management work orders regarding system not operating normally back to when they took possession of the space
Maintenance filled the refrigerant without locating the leak and called it good
Installation of the system is extremely poor quality
Traced refrigerant line set through the restaurant next door's basement
Unsure how the lines are ran to get to the indoor head between the restaurant wall and theirs

Recommend replacing the system and the line set
All of these issues are pre-existing to the customer taking possession of the space from the rental company

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on two Carrier high efficiency furnaces. Replaced both 20x25x4 air filters. Humidifier pads in new condition. Cleaned flame sensors and checked ignitors. Visual inspection of burners. Flush condensation trap and drain lines. Run test each system in both stages of heating. Both are operating properly and within specs for temperature rise, and blower and inducer motor amp draw. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Run test humidifiers during heating operations. Sunny explained colder temperature in smaller kitchen area. Dampened down vents near thermostat and sensor to prevent short cycling, and to force more air into that area. Also adjusted continuous fan speed up to move more air during idle time, and turned Dan more to on to continuously circulate air to even out temperature between rooms.


Nate G.

Nate G. Job Checkin

Performed heating maintenance on a 2005 Rheem 80% efficient single stage natural gas furnace 16x25x1 filter is in new condition Pulled flame sensor and cleaned Blower motor capacitor measuring 7.0mfd, rating is 7.5 Blower is very dirty Cleared inducer pressure switch port Performed run test and combustion analysis Furnace is overheating due to the dirty blower and shutting down on the high temperature limit Combustion test readings are healthy In an attempt to stop the high limit trips, increased blower speed to high and decreased gas pressure (2.3"wc, spec is 3.5") Run time is longer but still hits the high limit after 6 minutes of run time **Strongly recommend the blower cleaning we quoted** No safety concerns with the furnace, but it is not running at manufacturer's specifications due to the dirty blower Furnace may not be able to keep up on extremely cold days

Performed heating maintenance on a 2005 Rheem 80% efficient single stage natural gas furnace 
16x25x1 filter is in new condition 
Pulled flame sensor and cleaned
Blower motor capacitor measuring 7.0mfd, rating is 7.5
Blower is very dirty
Cleared inducer pressure switch port
Performed run test and combustion analysis
Furnace is overheating due to the dirty blower and shutting down on the high temperature limit
Combustion test readings are healthy
In an attempt to stop the high limit trips, increased blower speed to high and decreased gas pressure (2.3"wc, spec is 3.5")  Run time is longer but still hits the high limit after 6 minutes of run time
**Strongly recommend the blower cleaning we quoted**
No safety concerns with the furnace, but it is not running at manufacturer's specifications due to the dirty blower 
Furnace may not be able to keep up on extremely cold days Performed heating maintenance on a 2005 Rheem 80% efficient single stage natural gas furnace 
16x25x1 filter is in new condition 
Pulled flame sensor and cleaned
Blower motor capacitor measuring 7.0mfd, rating is 7.5
Blower is very dirty
Cleared inducer pressure switch port
Performed run test and combustion analysis
Furnace is overheating due to the dirty blower and shutting down on the high temperature limit
Combustion test readings are healthy
In an attempt to stop the high limit trips, increased blower speed to high and decreased gas pressure (2.3"wc, spec is 3.5")  Run time is longer but still hits the high limit after 6 minutes of run time
**Strongly recommend the blower cleaning we quoted**
No safety concerns with the furnace, but it is not running at manufacturer's specifications due to the dirty blower 
Furnace may not be able to keep up on extremely cold days

Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x1 clean Clean flame sensor Inspect burners - rusty replaced with stainless steel Ohm test igniter: 56.2 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: #10 in a #35 case -off for leaking safety Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.42 Check amp draw on inducer motor:0.84 Check delta T - 66° Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Upon arrival, inspected system and found unit in a code 3 inspected furnace intake and found leaves blocking intake cleared leaves from intake and started system. System started up and began heating no problem.


Brandon P.

Brandon P. Job Checkin

Plugged gas orifice on burner with igniter. used thermostat wire to unplug. No more ignition issues during multiple test runs.