725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews

Rated 4.9 out of 5 stars based on 345 customer reviews

Excellent Service by Gregg and his colleague

Greg and his colleague did awesome job balancing and providing recommendations. He also uncovered an issue that was kind a hidden.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

We have used Weston air on several properties and the service is always professional and mechanically well done. The price is fair. What we like is that it’s very realizable,

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding Company!

We have been a customer of Westin Air for four years now and recently had our old HVAC system replaced by Westin Air. They are the most professional HVAC company we’ve ever had with outstanding service and technical excellent. When I had a question about a new sound from our new system when turning on the furnace, Wes the owner personally came to the house to check it out (the sound was normal to the new system). What service! If you have any HVAC needs, call Westin Air.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Chris was great

Showed up in a timely manner and explained everything very well

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Attention to detail

Chris has a great attention to detail and is always willing to help us with our Energy Star Program

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Quality personnel

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service Professional employees!

Very responsive and gets the job done!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Service man showed up on time. Found part to be replaced and explained the problem. Also, gave us an overall status of the unit.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great communication

Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick Response & Excellent Service!

Westin Air continues to exceed my expectations for responsiveness and quality of service! Everyone is extremely friendly, understand and accommodating to help make the situation right! I would highly recommend Westin Air to anyone who wants a reliable, friendly and HONEST HVAC company!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and quick response!

Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Experience!

Chris was Amazing!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

A professional in your own neighborhood

I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs

  • Overall Experience
  • Quality
  • Price
  • Convenience

Takes Pride

Chris takes pride in his works and cares about things getting done properly!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Nate G.

Nate G. Job Checkin

Diagnosed gas leaks. New gas connections associated with the furnace install are leak free. Gad leaks are at water heater connections and existing galvanized gas line. Recommend having new gas line installed by a licensed plumber.


seth p.

seth p. Job Checkin

Replace one of two OEM 3-speed flow center pumps Bell & Gossett New right side pump on flow center NRF-36 103400 1M32 Old pump 208 230 1.2 amps New pump 115 amp 2.3 amps


Jeramie T.

Jeramie T. Job Checkin

Furnace not operating upon arrival. DISCOVERED DEFECTIVE indoor blower motor. Motor receiving 120v and capacitor reading 3uf. Tested with mini turbo 5uf and blower motor not engaging. Client would like to have estimate for repairs and replacement for Furnace. System is not operating at departure


Nate G.

Nate G. Job Checkin

Customer concern was noise at startup and shutdown of the heat and more noise from the second floor return during operation. Increased set point to initiate a call for heat. The audible click of the humidifier water solenoid valve could clearly be heard throughout the hoise. The noise from the second floor return was the fan of the humidifier transmitting noise through the ductwork. Cycled humidifier on and off while customer stood under the return grille. He verified the noise was the humidifier and asked it be shut off. Explained the benefits of the humidifier and the maintenance requirements for it. He said his small child is scared of the noise and wishes to not use it as a result.


Graham M.

Graham M. Job Checkin

Upon arrival inspected thermostat and believed to hear a furnace in the back of building so after investigating found the furnace was not an RTU unit was actually a residential furnace in the back closet. Unit was stuck running the inducer motor due to a control board short. Locking unit out for pressure switch won’t open. Unit needs a new control board to operate for further testing to be done.


Nate G.

Nate G. Job Checkin

Performed maintenance checkup on a Trane 96% efficient Two stage gas furnace Pulled and cleaned flame sensor Blew out Condensate trap High fire gas 3.5" Temp rise 48 degrees Low fire gas 1.9" Temp rise 47 degrees Replaced 20x25x4 filter Trimmed blocked drain monitor pressure switch tubing per the installation manual instructions. System is operating within manufacturer's specifications at this time.


Brandon P.

Brandon P. Job Checkin

Humidifier drain hose was pulled out of drain pump and draining directly onto the floor. Reinserted drain hose and tested operation of drain pump. Geothermal unit kicked on in heating while on site.


Jeramie T.

Jeramie T. Job Checkin

System not operating upon arrival. Discovered 60a and 30a breakers OFF at air handler.Engaged breakers and System became operational. AMP Draw on ecm blower .9a and heating elements 20.1a. Discharge air 123° with intake of 51°. CYCLED system multiple times and no issues. System is operating normal at this time.Filter 20x25x1 and like new.Contacters are burnt needs replacement single and dual in air handler.


Brandon P.

Brandon P. Job Checkin

2022 Carrier propane furnace operating in great condition. 20x25x4 air filter in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in EM-Heating mode from thermostat. Delta t of 56F with supply temp of 128F. Propane furnace is operating properly, efficiently and ready for Winter. Test ran system in heating mode to verify proper operation of geothermal.


Nate G.

Nate G. Job Checkin

Modified wiring for float switches to alarm terminals, twisted unused stat wire pairs to ground for shielding, changed humidifier wiring to 24V terminals. Master bedroom furnace needs a new humidifier solenoid, coil is open. Noise on 2nd floor is from 3 tons of air moving through a 2 ton duct system. He understands and will not run fan over medium.


Graham M.

Graham M. Job Checkin

Upon arrival was informed of RTU2 fire alarm went off minutes before arrival. Did not discover any causes or concerns on smoke alarm circuit, RTU on West side needs the heat exchanger replaced, unit has began forming holes in the bends and is becoming unsafe to operate. Installed CO detector in harvest by the bathrooms. Quote for heat exchanger is currently being discussed with Justin.


Wes  S.

Wes S. Job Checkin

Daikin Fit system installation near Powell.

Daikin Fit system installation near Powell.

Jeramie T.

Jeramie T. Job Checkin

Furnace operating upon arrival. Performed combustion analysis. Found no traces of carbon monoxide in return air or supply air at this time. Temperature rise of 62°.Furnace filter 16x25x1 need replacement soon. Removed high limit to inspect heat exchanger with camera. NO signs of holes or cracks at the best of my ability. Opened dampers to first floor supply air to prevent Furnace from tripping high limit. Furnace is operating normal and safe at this time


seth p.

seth p. Job Checkin

2014 Carrier GT geothermal three ton non-pressurized two pump glycol. Antifreeze freeze protection is tests between 30 and 35% roughly +5to +10°f freeze protection Electrical diagnostics and repairs Pull new thermostat wire from first floor to basement equipment, confirm correct thermostat setup, trace electrical short to faulty high pressure switch causing equipment to enter limp mode running the compressor, blower fan, and flow center non-stop ”attempting to reset the high pressure switch”. Bypass high pressure switch, research control board dip switch settings. Run test heat pump in low stage and high stage with 87° supply temp and 140° with auxiliary engaged Homeowner understands the water flow restrictions through the DHW heat exchanger and will reroute the 1 in glycol lines ASAP. Running refrigerant pressures under today's conditions are 95 and 300 psi Due to water flow restrictions through the DHW the glycol temperature drop is nearly triple the book specs from 63 to 38


Nate G.

Nate G. Job Checkin

Diagnosed failed heat exchanger. Furnace was locked out on tripped rollout. Reset, flames rolled out with blower operation. No data tag on the furnace. It's either 75 or 100,000 btu. Wants furnace Replaced ASAP.