Greg and his colleague did awesome job balancing and providing recommendations. He also uncovered an issue that was kind a hidden.
Overall Experience
Quality
Price
Convenience
We have used Weston air on several properties and the service is always professional and mechanically well done. The price is fair. What we like is that it’s very realizable,
Overall Experience
Quality
Price
Convenience
We have been a customer of Westin Air for four years now and recently had our old HVAC system replaced by Westin Air. They are the most professional HVAC company we’ve ever had with outstanding service and technical excellent. When I had a question about a new sound from our new system when turning on the furnace, Wes the owner personally came to the house to check it out (the sound was normal to the new system). What service! If you have any HVAC needs, call Westin Air.
Overall Experience
Quality
Price
Convenience
Showed up in a timely manner and explained everything very well
Overall Experience
Quality
Price
Convenience
Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.
Overall Experience
Quality
Price
Convenience
Chris has a great attention to detail and is always willing to help us with our Energy Star Program
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Very responsive and gets the job done!
Overall Experience
Quality
Price
Convenience
Service man showed up on time. Found part to be replaced and explained the problem. Also, gave us an overall status of the unit.
Overall Experience
Quality
Price
Convenience
Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.
Overall Experience
Quality
Price
Convenience
Westin Air continues to exceed my expectations for responsiveness and quality of service! Everyone is extremely friendly, understand and accommodating to help make the situation right! I would highly recommend Westin Air to anyone who wants a reliable, friendly and HONEST HVAC company!!
Overall Experience
Quality
Price
Convenience
Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs
Overall Experience
Quality
Price
Convenience
Chris takes pride in his works and cares about things getting done properly!
Overall Experience
Quality
Price
Convenience
Preventative maintenence inspection on Tempstar high efficiency gas furnace. 20x25x1 air filter is new today. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Humidifier damper is open, pad in good condition. Run test furnace in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Humidifier tested during heating mode test. All things tested were measuring within specifications. System is operating properly, efficiently and ready for Winter.
Remove and replace warranty 60a breaker test run heat post repairs and verify proper operation Unit heating at 24° delta T Refrigerant within spec during heat at 301/95 Airflow proper around 890cfm
Performed heating maintenance Cleaned flame sensor Found condensate trap gasket leaking water Replaced gasket Blower clean 20x25x1 Filter is good Burners are in new condition High fire gas pressure set to 3.2"wc Temperature rise 53⁰ Low fire gas pressure set to 1.3"wc Temperature rise 46⁰ Furnace is operating within factory specifications at this time
Preventative maintenence inspection on 1999 Bryant gas furnace. System is running in good condition despite age. 16x25x1 air filter is in new condition. Clean flame sensor and check ignitor ohms. Replaced blower capacitor as current 7.5uf was reading out of spec at 6.9uf. Test run in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. 4" galvanized B-vent in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly at this time. Due to age of the unit, it is recommended to start planning for replacement although it is currently operating properly.
Daikin heat pump preventative maintenance performed Turn heat on at thermostat Check filter: 16x20x1 ok Check volt and amp draw on heating elements: Blower motor : ECM motor no concerns Temp rise at — for emergency heat defrost on outdoor unit reversing valve is operational Air handler and heat pump in optimal running conditions
System was satisfying, desired temperature upon arrival. Inspected system and found no errors present. Homeowner informed me that furnace was back in a code one when he had to reset it. Informed homeowner that we will have to order the P1 pressure switch. To resolve issue due to a failed switch. Inspected drain and everything was clear and inducer motor was not pulling high amps. It was staying at 2.4 operational. Rated 2.7 Fla. unable to quote tonight due to being passed Goodman hours.
Preventative maintenence inspection on Carrier high efficiency gas furnace. 20x25x1 air filter in new condition. Clean flame sensor and check ignitor ohms. Flush condensation trap and drain lines. Run test unit in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.
Basement East system is frozen solid. Turn fan on and will return for diagnosis once unit has thawed out.
Gas heating preventative maintenance performed Check filter - 4” media ok Clean flame sensor Inspect burners - pull and brush Ohm test igniter: 16.7 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.28 Check amp draw on inducer motor:0.64 Check delta T - 62° Furnace is in optimal running conditions
Install new OEM Rheem heat exchanger on RTU unit #14 Note: RTU system age 19 years This estimate covers the specific repairs outlined to restore basic functionality to your existing HVAC system. Please note that the equipment is in poor overall condition with significant age-related wear, corrosion, and/or component degradation. Even after these repairs are completed, additional failures remain highly likely in the near future due to the system’s advanced age and deterioration. These repairs are considered a temporary measure and do not guarantee long-term reliability or restore the system to like-new condition. Unexpected breakdowns, reduced efficiency, and further repair costs are still probable. For greater reliability, energy savings, and peace of mind, replacement of the system may be the more cost-effective long-term solution. Per Jim: diagnostic on RTU11 not working at all, broken thermostat wire for rtu14, AND find the source of the noise from Elliot's restaurant systems. R
Preventative maintenence inspection on Trane furnace. 16x25x4 air filter is in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Test ran in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. 4" galvanized B-vent in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.
Gas heating preventative maintenance performed Check filter - 216 popup ok Clean flame sensor Inspect burners - dirty replacement stainless steel recommended clean for now. Ohm test igniter: 41.6 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: new today #35 Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.24 Check amp draw on inducer motor:0.74 Check delta T - 54° Furnace is in optimal running conditions
Replacement warranty. Upon arrival, thermostat was in off mode. Inspected furnace for any obvious issues and found d that the furnace control board was not being powered. Removed door and pushed in door switch to check for power. With door switch pushed in by hand, the system came on. Put bottom door back on and noticed that the door was not pushing the door switch in all of the way as the door switch was hanging lower than it should be. Adjusted door switch for proper height and put door back on. With door on, system now has power. Turned thermostat to heating to check for any other issues. None found or suspected. Bob mentioned he would like a quote to install a ductless mini split in the garage. Photos on file of furnace for humidifier install, aswell as interior and exterior photos for mini split install.
Upon arrival inspected system and found unit in ignition failure code 4. Flame sensor was filthy igniter tested at 120ohms standard M style igniter. Test run unit with clean flame sensor and had no issues. Found vent pipe had multiple splits in pipe allowing exhaust gases to leak. Repaired with tape to keep system safe while temporarily operating and quote repair to vent pipe three 5 foot sections of 4” pipe and 3 90° 4” standard 1 90° 4” double