725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews

Rated 4.9 out of 5 stars based on 345 customer reviews

Excellent Service by Gregg and his colleague

Greg and his colleague did awesome job balancing and providing recommendations. He also uncovered an issue that was kind a hidden.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

We have used Weston air on several properties and the service is always professional and mechanically well done. The price is fair. What we like is that it’s very realizable,

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding Company!

We have been a customer of Westin Air for four years now and recently had our old HVAC system replaced by Westin Air. They are the most professional HVAC company we’ve ever had with outstanding service and technical excellent. When I had a question about a new sound from our new system when turning on the furnace, Wes the owner personally came to the house to check it out (the sound was normal to the new system). What service! If you have any HVAC needs, call Westin Air.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Chris was great

Showed up in a timely manner and explained everything very well

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Attention to detail

Chris has a great attention to detail and is always willing to help us with our Energy Star Program

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Quality personnel

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service Professional employees!

Very responsive and gets the job done!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Service man showed up on time. Found part to be replaced and explained the problem. Also, gave us an overall status of the unit.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great communication

Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick Response & Excellent Service!

Westin Air continues to exceed my expectations for responsiveness and quality of service! Everyone is extremely friendly, understand and accommodating to help make the situation right! I would highly recommend Westin Air to anyone who wants a reliable, friendly and HONEST HVAC company!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and quick response!

Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Experience!

Chris was Amazing!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

A professional in your own neighborhood

I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs

  • Overall Experience
  • Quality
  • Price
  • Convenience

Takes Pride

Chris takes pride in his works and cares about things getting done properly!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Graham M.

Graham M. Job Checkin

Upon arrival inspected system and found inducer motor was seized and not operating. Quote replacement inducer motor and test run system, furnace blower not cycling after heat up cycle. Blower getting power but will not come on. Capacitor 10mfd @ 10mfd motor bad and needs replaced. Will have to return tomorrow to replace furnace blower motor. Remove and replace blower motor test run heat. Clean blower wheel and housing of dust buildup due to electronic air filter. No concerns post repair

Upon arrival inspected system and found inducer motor was seized and not operating. Quote replacement inducer motor and test run system, furnace blower not cycling after heat up cycle. Blower getting power but will not come on. Capacitor 10mfd @ 10mfd motor bad and needs replaced. Will have to return tomorrow to replace furnace blower motor. 


Remove and replace blower motor test run heat. Clean blower wheel and housing of dust buildup due to electronic air filter. No concerns post repair

Brandon P.

Brandon P. Job Checkin

50a fuse failure on 240v circuit. Heat strips are not getting proper power. Replaced fuses with non-fused connections since main breaker is rated properly. Test run two remaining heat strips. Both are pulling approximately 20A and within range. System is operwtingnin both geothermal and auxiliary at this time.


Graham M.

Graham M. Job Checkin

Upon arrival, inspected system and found inducer motor was seized. Pull inducer motor remove debris from housing and free motor by hand. Bearings are extremely stiff with age of unit and the unlikelihood of getting a motor available today, Oiled motor and test ran system with current motor. Got system operational temporarily will have to return and replace motor or replace whole system if customer prefers alternative route.

Upon arrival, inspected system and found inducer motor was seized. Pull inducer motor remove debris from housing and free motor by hand. Bearings are extremely stiff with age of unit and the unlikelihood of getting a motor available today, Oiled motor and test ran system with current motor. Got system operational temporarily will have to return and replace motor or replace whole system if customer prefers alternative route. Upon arrival, inspected system and found inducer motor was seized. Pull inducer motor remove debris from housing and free motor by hand. Bearings are extremely stiff with age of unit and the unlikelihood of getting a motor available today, Oiled motor and test ran system with current motor. Got system operational temporarily will have to return and replace motor or replace whole system if customer prefers alternative route.

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Carrier air handler. Upon arrival, system was operating in heat pump heating. Performed non-invasive refrigerant test by testing refrigerant temperatures. Gas line temperature of 123F is within spec. Outdoor ambient temp of 35F and gas line should be 80-100F above outdoor temperature. No issues suspected with refrigerant. Tested operation of electric strip heat. All stips come on as should and operate within Amp draw specs. Blower motor is operating properly. Cleaned air filter and replaced tape to cover filter slot. No issues found or suspected with equipment. System is operating properly, efficiently and ready for Winter.


Graham M.

Graham M. Job Checkin

Remove 4” vent pipe and replace with new pipe due to rust and rot causing vent to separate and leak exhaust gases into basement. Temporarily taped for safety reasons


Graham M.

Graham M. Job Checkin

Unit is satisfying demand and not throwing any codes.

Unit is satisfying demand and not throwing any codes. Unit is satisfying demand and not throwing any codes.

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Carrier high efficiency furnace running in great condition. 20x25x4 air filter is new today. Humidifier pad in good condition and damper opened. Confirmed water is on. Humidifier is operating properly. On furnace, clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Furnace is operating properly, efficiently and ready for Winter. Humidifier is operating properly. Humidity level issues are a combination of low outdoor temperature and being supplied with cold water. Due to lower cold water temperature, the Humidifier is not able to evaporate a sufficient amount compared to using hot water. System is supplied with cold water as water supply valve being used was installed by plumbers during construction. I


Graham M.

Graham M. Job Checkin

Upon arrival inspected system and found gas valve getting power but not opening. Tapped on valve and valve opened up on second try. Quoted replacement valve and replace upon approval. Install union after shut off due to it being missing and having to shut off main house, gas line. Test Ron, furnace and unit cycled no problem after.


Brandon P.

Brandon P. Job Checkin

Upon arrival, David mentioned a clicking noise coming from the furnace. Inspection shows that blower wheel blades has loosened from the center wheel. Blower wheel blades are skipping on the center wheel causing the noise. Blower wheel will need replaced. Performed cleaning portion of preventative maintenence inspection. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Replace #35 water panel in humidifier and set water flow. 20x25x4 air filter in decent condition. Check again in 1-2 months. Test unit in heating mode from thermostat. Did not check temperature rise as an accurate reading is not possible with current faulty blower wheel.


Nate G.

Nate G. Job Checkin

Diagnosed failed gas valve 24V present at MV terminal, valve clicks but no gas flows

Diagnosed failed gas valve
24V present at MV terminal, valve clicks but no gas flows Diagnosed failed gas valve
24V present at MV terminal, valve clicks but no gas flows

Jason D.

Jason D. Job Checkin

Install new Bryant HVAC system Equipment: Package H/P - 605CNXB60000 *Honeywell thermostat Installation: *Reconnect to existing high voltage electric circuit *Transition to existing supply and return ductwork *Start up and commission the new system Warranty: Bryant manufacturers parts warranty (Annual maintenance must be performed) 1 Year Westin Air labor warranty (Annual maintenance must be performed)


Install new Bryant HVAC system

Equipment:
Package H/P - 605CNXB60000
*Honeywell thermostat

Installation:
*Reconnect to existing high voltage electric circuit
*Transition to existing supply and return ductwork
*Start up and commission the new system

Warranty:
Bryant manufacturers parts warranty (Annual maintenance must be performed)
1 Year Westin Air labor warranty (Annual maintenance must be performed)



Install new Bryant HVAC system

Equipment:
Package H/P - 605CNXB60000
*Honeywell thermostat

Installation:
*Reconnect to existing high voltage electric circuit
*Transition to existing supply and return ductwork
*Start up and commission the new system

Warranty:
Bryant manufacturers parts warranty (Annual maintenance must be performed)
1 Year Westin Air labor warranty (Annual maintenance must be performed)

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Trane furnace. 16x25x1 air filter in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Test ran system in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. 4" galvanized B-vent in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.


Nate G.

Nate G. Job Checkin

Diagnosed failed inducer motor bearings Was able to spin motor free It will stop working again in short order if it is not replaced Sent quote for replacement We can also quote to replace the furnace and AC system due to age and likely future repairs This invoice is payable online

Diagnosed failed inducer motor bearings 
Was able to spin motor free
It will stop working again in short order if it is not replaced
Sent quote for replacement
We can also quote to replace the furnace and AC system due to age and likely future repairs

This invoice is payable online

Nate G.

Nate G. Job Checkin

Replacement warranty Moved steam humidifier dispersion Manifold to the return drop Sealed old hole with foil tape Checked thermostat settings and calibration for humidity Noticed humidifier draining and filling excessively Changed canister amp draw from 16A to 11.5A Humidifier is now heating the water without excess drain cycles to self adjust water conductivity


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 16x25x1 clean Clean flame sensor Inspect burners - no concerns Ohm test igniter: 54.6 Inspect wiring for loose connections and/or hot spots - no concerns Check humidifier pad: n/a Inspect exhaust flu - 80% no concerns Set thermostat for heat Check amp draw on blower motor: 3.2 Check amp draw on inducer motor:0.6 Check delta T - 49° Furnace is in optimal running conditions