Greg and his colleague did awesome job balancing and providing recommendations. He also uncovered an issue that was kind a hidden.
Overall Experience
Quality
Price
Convenience
We have used Weston air on several properties and the service is always professional and mechanically well done. The price is fair. What we like is that it’s very realizable,
Overall Experience
Quality
Price
Convenience
We have been a customer of Westin Air for four years now and recently had our old HVAC system replaced by Westin Air. They are the most professional HVAC company we’ve ever had with outstanding service and technical excellent. When I had a question about a new sound from our new system when turning on the furnace, Wes the owner personally came to the house to check it out (the sound was normal to the new system). What service! If you have any HVAC needs, call Westin Air.
Overall Experience
Quality
Price
Convenience
Showed up in a timely manner and explained everything very well
Overall Experience
Quality
Price
Convenience
Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.
Overall Experience
Quality
Price
Convenience
Chris has a great attention to detail and is always willing to help us with our Energy Star Program
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Very responsive and gets the job done!
Overall Experience
Quality
Price
Convenience
Service man showed up on time. Found part to be replaced and explained the problem. Also, gave us an overall status of the unit.
Overall Experience
Quality
Price
Convenience
Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.
Overall Experience
Quality
Price
Convenience
Westin Air continues to exceed my expectations for responsiveness and quality of service! Everyone is extremely friendly, understand and accommodating to help make the situation right! I would highly recommend Westin Air to anyone who wants a reliable, friendly and HONEST HVAC company!!
Overall Experience
Quality
Price
Convenience
Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs
Overall Experience
Quality
Price
Convenience
Chris takes pride in his works and cares about things getting done properly!
Overall Experience
Quality
Price
Convenience
Concentric intake/exhaust termination kit installed incorrectly so the exhaust was being directed back towards the house. Large gaps present in the J block around the pipes. Put thumb gum putty around the pipes and installed termination kit in the correct orientation.
Gas heating preventative maintenance performed Check filter - 20x25x1 new today Clean flame sensor Inspect burners - clean Ohm test igniter: 54.5 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 4.2 Check amp draw on inducer motor:0.92 Check delta T - 57° Furnace is in optimal running conditions
Replace failed control board with new OEM control board and test operation. Parts covered under warranty. Labor is not. System is currently operational in heating.
Preventative maintenence inspection performed. Change filters and blowrr belt, clean flame sensor and ignitor. Visual inspection of heat exchanger. Test run operation of heating. Blower and inducer motors tested good. No issues found or suspected.
Replace filters Inspect heat exhanger Clean flame sensor Test run heat No concerns with unit
Preventative maintenence inspection performed. Change filters, clean flame sensor and ignitor. Visual inspection of heat exchanger. Test run operation of heating. Blower and inducer motors tested good. No issues found or suspected.
Replace air filters Test run heat Clean flame sensors for both units Inspect heat exchangers and verify safe for operation. No concerns found
Preventative maintenence inspection performed. Change filters, clean flame sensor and ignitor. Visual inspection of heat exchanger. Test run operation of heating. Blower and inducer motors tested good. No issues found or suspected.
Removed 5 min compressor delay, set to 0 (defrost board has its own short cycle protection) Changed furnace lockout to 45⁰ Changed HP lockout to 25⁰ Set 2⁰ droop Left 5hr upstage timer Heat pump ran the entire time I had the thermostat in test mode
Performed heating maintenance on an 'aquatherm' style ADP air handler Flushed hot water tank Checked blower capacitor Replaced 12x20x1 filter AC evaporator coil clean Blower wheel clean Hot water coil clean Controls operating properly on the air handler (blower thermostat for water temperature) Electrical connections are secure and show no signs of overheating 0ppm carbon monoxide present around the water heater No gas leaks detected No water leaks present System operating normally at this time Renewed silver maintenance with monthly payment option
Upon arrival, thermostats are properly set. Inspection of furnace shows a code e11 for gas valve error. Upon checking the gas valve, found no error. Called Trane tech support who confirmed that it is a bad controlboard. Control board is ordered and will call back to schedule once parts are in hand.
Blower motor failed on E series water furnace geo Replaced blower motor System operating normally at this time Water heater top heating element failed
Multiple issues to address upon arrival, inspected observatory and found no hot water going to 2nd level for observatory or kids wing. Inspected boilers and units were in burner lockout status. Restarted boiler with Ralph’s permission and verified heating reaches 2nd floor post restarting boilers. Units heating up stairs now and humidity should come down with operation, set point for thermostat at 40%. No dehumidifiers on 2nd level basement units all at 50% for dehumidification. Master humidifier is at 40% and functioning. Beauty salon humidifier was not running, turned humidifier on for salon. Adjusted blower speeds on master system to minimum allowed set point to reduce as much blower noise as possible. Dessert air system tripped on high pressure error. Found no concerns with dessert Aire after restarting unit.
Upon arrival, there is visible water standing in bottom of furnace cabinet, aswell as a bit around the bottom air box on the floor. Poured water into drain system to locate leak. Found the cabinet penatration fitting leaking at the threaded connection. Disassembled and added Teflon tape to seal the threads. Poured more water through the system and no other leaks were found. Current standing water may take a day or two to dry up. During leak search, noticed that the inducer motor had an extensive amount of water damage. Femi also informed that there has been a previous failed gas valve that needed replaced, aswell as an extensive history of rusty burners and eventually had the burners replaced entirely. All of these issues are common problems with systems that do not have an intake air drain trap installed. During the summer, hot, humid air naturally moving through the vent system is able to condensate, and drip onto the internal components, he inducer motor, gas valve, and burners. I