Greg and his colleague did awesome job balancing and providing recommendations. He also uncovered an issue that was kind a hidden.
Overall Experience
Quality
Price
Convenience
We have used Weston air on several properties and the service is always professional and mechanically well done. The price is fair. What we like is that it’s very realizable,
Overall Experience
Quality
Price
Convenience
We have been a customer of Westin Air for four years now and recently had our old HVAC system replaced by Westin Air. They are the most professional HVAC company we’ve ever had with outstanding service and technical excellent. When I had a question about a new sound from our new system when turning on the furnace, Wes the owner personally came to the house to check it out (the sound was normal to the new system). What service! If you have any HVAC needs, call Westin Air.
Overall Experience
Quality
Price
Convenience
Showed up in a timely manner and explained everything very well
Overall Experience
Quality
Price
Convenience
Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.
Overall Experience
Quality
Price
Convenience
Chris has a great attention to detail and is always willing to help us with our Energy Star Program
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Very responsive and gets the job done!
Overall Experience
Quality
Price
Convenience
Service man showed up on time. Found part to be replaced and explained the problem. Also, gave us an overall status of the unit.
Overall Experience
Quality
Price
Convenience
Working with Chris is always easy. He is almost always available to talk and responsive to when I have something I need help with. Willing to answer any questions I have and always trying to make things right for me and the client.
Overall Experience
Quality
Price
Convenience
Westin Air continues to exceed my expectations for responsiveness and quality of service! Everyone is extremely friendly, understand and accommodating to help make the situation right! I would highly recommend Westin Air to anyone who wants a reliable, friendly and HONEST HVAC company!!
Overall Experience
Quality
Price
Convenience
Chris is quick to respond and is a man of his word. He is passionate about what he does and is quality driven.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
I, Seth Peters, am a 18-year veteran and Employee #1 of Westin Air. We specialize in WaterFurnace geothermal, daiken and mitsubishi many split and whole home equipment, new construction and replacement installs
Overall Experience
Quality
Price
Convenience
Chris takes pride in his works and cares about things getting done properly!
Overall Experience
Quality
Price
Convenience
Furnace had stored ignition failure codes Flame sensor signal was 6.0 micro amps before cleaning Signal rose to 6.7 after cleaning Checked gas pressure, standing inlet was 10.8" Homeowner adjusted regulator to 13" with the furnace operating Manifold pressure 11" Suspect low gas pressure from potentially frozen regulator No issues found with the furnace itself Exhaust pipe is clear
Upon arrival inspected system and found control board was not properly displaying status. Inspected further and light started flickering while checking board. Connections broken and causing intermittent issues. Control board needs replaced. With age of furnace recomending replacement over repair due to risk of further part failure - Melvin is ready to replace control board but would like a quote for the furnace just to know a price because unit is intermittently operational. I have recommended that he hold off on repair until he has decided on replacement.
Inspection of geothermal unit shows that domestic water line portion of geothermal hot water generator setup is leaking water. Shut off water supply lines to geothermal and turn off HWG switch. This will not hinder geothermal operation. Test ran system in geothermal heating. No other issues with geothermal heating were found or suspected. Cathy will be notified to draw an estimate for full system replacement since the current repair in not possible.
Upon arrival, inspected wiring and found thermostat was properly wired to control humidifier but humidifier was stuck running constantly with heat. Rewired to make furnace control rather than thermostat. Thermostat will still signal it, but furnace is the actual one sending 24 V to it. Humidifier is no longer stuck operating while not having a demand.
Furnace working properly upon arrival Stored fault code 32 for pressure switch Intake screen clear, drain trap clear Possible snow/ice restricting exhaust that needed to melt
Initial inspection if furnace shows that code 3 is active. Code 3 is for pressure switch or inducer error. Further inspection of unit showed that the intake mesh is partially clogged with leaf and bug debris. Inspection of outdoor termination shows that the intake flange is partially clogged with snow and ice. Remove debris from mesh and snow from outdoor intake and test run operation of unit. System is draining water correctly and inducer motor is operating properly. No other issues found or suspected while on site.
Inducer motor is ready to fail any minute, this will stop the furnace from heating at all Getting 1ppm carbon monoxide off the front of the furnace and intermittently around the house on the first floor Considering age of the furnace and AC, cost of repairs required and the fact it's putting off carbon monoxide, strongly recommend system replacement. 2002 Lennox 100kbtu 21" wide 90% furnace 3" intake and exhaust solid core PVC 3.5 ton AC 15' line set 10x24 return drop (2) 8x20 supply trunks 20x25x1 Filter rack 5-conductor thermostat wire to the stat, easy to pull new wire, roughly 20' of wire
2013 Comfortmaker high efficiency furnace running in good condition. 20x25x1 air filter is new today. Clean flame sensor and check ignitor ohms. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.
Pressure switch stuck open Replaced pressure switch System heating normally at this time.
Furnace throwing high limit lockout fault (13) Adjusted temperature rise to maintain a steady 52⁰ Furnace would run 10 min or so and go into a 13 fault, never showed a 33 fault (33 fault MUST occurr before the 13 fault shows up) Sometimes it would be right back to a 13 fault after resetting the power While this was happening, using a volt meter, the high limit circuit was being monitored. Not once did the limit circuit actually open up when the 13 fault would occurr. Replaced control board Due to age and alleged history of refrigerant top off every summer for the past 5 years, recommend replacement of the system.
Upon arrival, inspected overlook system found no major concerns with unit. Inspected boilers per Ralph request and boiler #2 was faulted and needed restarted. After restarting boiler 2 temp went from 109 to 160. Once boiler was back up and running changed out all filters for house and car barn. Opened overlook doors to allow master bed air into overlook. Master bed system sounds to have a bad blower motor/blower wheel humming loudly at system and spreading through nearby registers. Warranty motor should be quoted to reduce noise. Pool house is not accessible today due to the snow. It is 2ft+ deep in most places.
01/23/2026 9:51:37 AM - Option 1 Install New Bryant Single (2) Stage Gas Furnace Model #: 927TA48080V17 Serial #: 80,000 BTU’s - 97% AFUE Installation: * Additional Services - New PVC furnace vents. Level 2 * Reconnect to existing gas line and high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system * 1" Standard Filter Rack Warranty: 20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
Upon arrival, system was operating with no unusual noises heard. Initial inspection of furnace shows that the collector box has started leaking and should be replaced to prevent future water damage to other components. During first fire off test, the blower and inducer motors came on with no unusual noise. After about 20 seconds, the blower motor started to make a high pitched whining noise. Noise lasted for approximately 10 seconds before going away. The noise is due to bearing failure in the motor. Blower motor is prone to fail at any moment and urgently needs replaced. System is currently operating in heat.
2018 Trane XR80 standard efficiency gas furnace running in good condition. 16x25x1 air filter in new condition. Clean flame sensor and check ignitor. Visual inspection of burners. Test blower capacitor. 7.5uf capacitor reading 5.8uf and is out of spec. Replace out of spec 7.5uf capacitor with new Turbo 200 universal capacitor. Includes 5 year parts warranty. Humming noise previously mentioned could have been caused by stress from the blower motor due to out of spec capacitor. Test ran operation in heat mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested within range for Amp draw. 4" galvanized B-vent in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.
10+ year old Mitsubishi mini split Not a hyper heat model Too cold to get compressor to start It does have refrigerant but unknown if correct amount No fault code flashing on indoor or outdoor units Recommend a Daikin Aurora (rated for cold climates) 12000 btu